Ferroli

Инструкция Ferroli Инструкция Ferroli Atlas 32 95

Архивный PDF-документ для ознакомления.

Инструкция · Русский · Обновлено: 11 августа 2026 г.

Оригинальный PDF

Завантаження PDF…

Оставить заявку мастеру

Нужна диагностика или помощь с инструкцией? Передайте мастеру модель котла и код ошибки.

Оставить заявку мастеру
Текст инструкции для поиска

Страница 1

6 cod. 3540S123 — 07/2010 (Rev. 00) ATLAS ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO KULLANMA, KURULUM VE BAKøM TALIMATLARø INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN ȅǻǾīǴǼȈ ȋȇdzȈǾȈ, ǼīȀǹȉDZȈȉǹȈǾȈ Ȁǹǿ ȈȊȃȉdzȇǾȈǾȈ AANWIJZINGEN VOOR GEBRUIK, INSTALLATIE EN ONDERHOUD ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ, ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ

Страница 1 PDF

Страница 2

ATLAS 2 IT cod. 3540S123 - 07/2010 (Rev. 00) IT 1. AVVERTENZE GENERALI • Leggere ed osservare attentamente le avvertenze contenute in questo libretto di istruzioni. • Dopo l’installazione della caldaia, informare l’utilizzatore sul funzionamento e con- segnargli il presente manuale che costituisce parte integrante ed essenziale del pro- dotto e deve essere conservato con cura per ogni ulteriore consultazione. • L’installazione e la manutenzione devono essere effettuate in ottemperanza alle norme vigenti, secondo le istruzioni del costruttore e devono essere eseguite da personale professionalmente qualificato. È vietato ogni intervento su organi di rego- lazione sigillati. • Un’errata installazione o una cattiva manutenzione possono causare danni a perso- ne, animali o cose. È esclusa qualsiasi responsabilità del costruttore per i danni cau- sati da errori nell’installazione e nell’uso e comunque per inosservanza delle istruzioni. • Prima di effettuare qualsiasi operazione di pulizia o di manutenzione, disinserire l’apparecchio dalla rete di alimentazione agendo sull’interruttore dell’impianto e/o attraverso gli appositi organi di intercettazione. • In caso di guasto e/o cattivo funzionamento dell’apparecchio, disattivarlo, astenen- dosi da qualsiasi tentativo di riparazione o di intervento diretto. Rivolgersi esclusiva- mente a personale professionalmente qualificato. L’eventuale riparazione- sostituzione dei prodotti dovrà essere effettuata solamente da personale professio- nalmente qualificato utilizzando esclusivamente ricambi originali. Il mancato rispetto di quanto sopra può compromettere la sicurezza dell’apparecchio. • Questo apparecchio dovrà essere destinato solo all’uso per il quale è stato espres- samente previsto. Ogni altro uso è da considerarsi improprio e quindi pericoloso. • Gli elementi dell’imballaggio non devono essere lasciati alla portata di bambini in quanto potenziali fonti di pericolo. • Le immagini riportate nel presente manuale sono una rappresentazione semplifica- ta del prodotto. In questa rappresentazione possono esserci lievi e non significative differenze con il prodotto fornito. 2. ISTRUZIONI D’USO 2.1 Presentazione Gentile Cliente, La ringraziamo di aver scelto una caldaia FERROLI di concezione avanzata, tecnologia d’avanguardia, elevata affidabilità e qualità costruttiva. La preghiamo di leggere attenta- mente il presente manuale perchè fornisce importanti indicazioni riguardanti la sicurezza di installazione, uso e manutenzione. ATLAS è un generatore di calore ad alto rendimento, per la produzione di acqua calda per il riscaldamento, adatto a funzionare con bruciatori soffiati a gas o gasolio. Il corpo caldaia è costituito da elementi in ghisa, assemblati con biconi e tiranti in acciaio, il cui profilo è stato particolarmente curato con un'ottimale ripartizione delle alette, che con- sente un'alta efficienza termica e conseguente alto risparmio energetico. 2.2 Pannello comandi fig. 1 - Pannello di controllo modelli ATLAS 32-78 fig. 2 - Pannello di controllo modelli ATLAS 95 Legenda 1 = Termometro 2 = Interruttore di accensione 3 = Termostato di sicurezza a riarmo manuale 4 = Manopola regolazione temperatura o 1° stadio 5 = Manopola regolazione temperatura 2° stadio 2.3 Accensione e spegnimento Accensione caldaia Aprire le valvole di intercettazione combustibile. Fornire alimentazione elettrica all'apparecchio. Premere il pulsante 2 di fig. 1 per alimentare caldaia e bruciatore. Fare riferimento al ma- nuale del bruciatore per il relativo funzionamento. Spegnimento caldaia Per brevi periodi di sosta è sufficiente premere il pulsante 2 di fig. 1 sul pannello comandi portandolo in posizione “0”. Per lunghi periodi di sosta, oltre ad agire sul pulsante 2, è d'obbligo chiudere anche la valvola di intercettazione del combustibile. Per lunghe soste durante il periodo invernale, onde evitare danni causati dal gelo, è necessario introdurre l'apposito antigelo nell'impianto o svuotare completamente l'impianto stesso. 2.4 Regolazioni Regolazione temperatura riscaldamento Impostare la temperatura impianto desiderata tramite il termostato di regolazione 4 di fig. 1. Per il modello ATLAS 95, impostare poi la temperatura del 2° stadio tramite il termostato di regolazione 5 ad una temperatura 10°C inferiore a quella del 1° stadio. A IMPORTANTE: la temperatura del 2° stadio deve essere sempre imposta- ta al di sotto di quella del 1° stadio.. fig. 3 - Regolazione temperatura modello ATLAS 95 Regolazione della temperatura ambiente (con termostato ambiente opzionale) Impostare tramite il termostato ambiente la temperatura desiderata all’interno dei locali. Nel caso non sia presente il termostato ambiente la caldaia provvede a mantenere l’im- pianto alla temperatura di setpoint mandata impianto impostata. 3. INSTALLAZIONE 3.1 Disposizioni generali L'INSTALLAZIONE DELLA CALDAIA DEVE ESSERE EFFETTUATA SOLTANTO DA PERSONALE SPECIALIZZATO E DI SICURA QUALIFICAZIONE, OTTEMPERANDO A TUTTE LE ISTRUZIONI RIPORTATE NEL PRESENTE MANUALE TECNICO, ALLE DI- SPOSIZIONI DI LEGGE VIGENTI, ALLE PRESCRIZIONI DELLE NORME NAZIONALI E LOCALI E SECONDO LE REGOLE DELLA BUONA TECNICA. 3.2 Luogo d’installazione La caldaia deve essere installata in apposito locale con aperture di aerazione verso l’esterno secondo quanto prescritto dalle norme vigenti. Se nello stesso locale vi sono più bruciatori o aspiratori che possono funzionare assieme, le aperture di aerazione de- vono essere dimensionate per il funzionamento contemporaneo di tutti gli apparecchi.Il luogo di installazione deve essere privo di oggetti o materiali infiammabili, gas corrosivi polveri o sostanze volatili che, richiamate dal ventilatore del bruciatore possano ostruire i condotti interni del bruciatore o la testa di combustione. L’ambiente deve essere asciut- to e non esposto a pioggia, neve o gelo. A Se l’apparecchio viene racchiuso entro mobili o montato affiancato lateralmen- te, deve essere previsto lo spazio per lo smontaggio della mantellatura e per le normali attività di manutenzione. Accertarsi in particolare che dopo il montaggio della caldaia con il bruciatore sulla porta anteriore, quest'ultima possa aprirsi senza che il bruciatore vada a sbattere contro pareti o altri ostacoli. 3.3 Collegamenti idraulici La potenzialità termica dell’apparecchio va stabilita preliminarmente con un calcolo del fabbisogno di calore dell’edificio secondo le norme vigenti. L’impianto deve essere corredato di tutti i compo- nenti per un corretto e regolare funzionamento. Si consiglia d’interporre, fra caldaia ed impianto di riscaldamento, delle valvole d’intercettazione che permettano, se necessario, d’isolare la caldaia dall’impianto. B Lo scarico della valvola di sicurezza deve essere collegato ad un imbuto o tubo di rac- colta, per evitare lo sgorgo di acqua a terra in caso di sovrapressione nel circuito di ri- scaldamento. In caso contrario, se la valvola di scarico dovesse intervenire allagando il locale, il costruttore della caldaia non potrà essere ritenuto responsabile. Non utilizzare i tubi degli impianti idraulici come messa a terra di apparecchi elettrici. Prima dell’installazione effettuare un lavaggio accurato di tutte le tubazioni dell’impianto per rimuo- vere residui o impurità che potrebbero compromettere il buon funzionamento dell’apparecchio. Effettuare gli allacciamenti ai corrispettivi attacchi secondo il disegno riportato al cap. 5 ed ai sim- boli riportati sull’apparecchio. A L’apparecchio non viene fornito di vaso d’espansione. Il suo collegamento pertanto, deve essere effettuato a cura dell’Installatore. Si ricorda a tal proposito, che la pressio- ne nell’impianto, a freddo, deve essere di 1 bar. Caratteristiche dell’acqua impianto In presenza di acqua con durezza superiore ai 25° Fr (1°F = 10ppm CaCO3), si prescrive l’uso di acqua opportunamente trattata, al fine di evitare possibili incrostazioni in caldaia. Il trattamento non deve ridurre la durezza a valori inferiori a 15°F (DPR 236/88 per utilizzi d’acqua destinati al consumo umano). È comunque indispensabile il trattamento dell’ac- qua utilizzata nel caso di impianti molto estesi o di frequenti immissioni di acqua di rein- tegro nell’impianto. B Nel caso in cui si installino decalcificatori in corrispondenza dell’entrata dell’ac- qua fredda alla caldaia, prestare particolare attenzione a non ridurre eccessi- vamente il grado di durezza dell’acqua in quanto potrebbe verificarsi un degrado prematuro dell’anodo di magnesio del bollitore.                                        

Страница 2 PDF

Страница 3

ATLAS 3 IT cod. 3540S123 - 07/2010 (Rev. 00) 6 Sistema antigelo, liquidi antigelo, additivi ed inibitori Qualora si renda necessario, è consentito l’uso di liquidi antigelo, additivi e inibitori, solo ed esclusivamente se il produttore di suddetti liquidi o additivi fornisce una garanzia che assicuri che i suoi prodotti sono idonei all’uso e non arrecano danni allo scambiatore di caldaia o ad altri componenti e/o materiali di caldaia ed impianto. È proibito l’uso di liquidi antingelo, additivi e inibitori generici, non espressamente adatti all’uso in impianti termici e compatibili con i materiali di caldaia ed impianto. 3.4 Collegamento bruciatore Il bruciatore a gasolio o a gas, ad aria soffiata per focolari pressurizzati, può essere uti- lizzato se le sue caratteristiche di funzionamento sono adatte alle dimensioni del focolare della caldaia ed alla sua sovrappressione. La scelta del bruciatore deve essere fatta pre- liminarmente seguendo le istruzioni del fabbricante, in funzione del campo di lavoro, dei consumi del combustibile e delle pressioni, nonchè della lunghezza della camera di com- bustione. Montare il bruciatore seguendo le istruzioni del Suo Costruttore. 3.5 Collegamenti elettrici Collegamento alla rete elettrica B La sicurezza elettrica dell’apparecchio è raggiunta soltanto quando lo stesso è correttamente collegato ad un efficace impianto di messa a terra eseguito come previsto dalle vigenti norme di sicurezza. Far verificare da personale professio- nalmente qualificato l’efficienza e l’adeguatezza dell’impianto di terra, il costrut- tore non è responsabile per eventuali danni causati dalla mancanza di messa a terra dell’impianto. Far verificare inoltre che l’impianto elettrico sia adeguato alla potenza massima assorbita dall’apparecchio, indicata in targhetta dati cal- daia. La caldaia è precablata e dotata di cavo di allacciamento alla linea elettrica di tipo "Y" sprovvisto di spina. I collegamenti alla rete devono essere eseguiti con allacciamento fis- so e dotati di un interruttore bipolare i cui contatti abbiano una apertura di almeno 3 mm, interponendo fusibili da 3A max tra caldaia e linea. E’ importante rispettare le polarità (LI- NEA: cavo marrone / NEUTRO: cavo blu / TERRA: cavo giallo-verde) negli allacciamenti alla linea elettrica. In fase di installazione o sostituzione del cavo di alimentazione, il con- duttore di terra deve essere lasciato 2 cm più lungo degli altri. B II cavo di alimentazione dell’apparecchio non deve essere sostituito dall’utente. In caso di danneggiamento del cavo, spegnere l’apparecchio e, per la sua so- stituzione, rivolgersi esclusivamente a personale professionalmente qualifica- to. In caso di sostituzione del cavo elettrico di alimentazione, utilizzare esclusivamente cavo “HAR H05 VV-F” 3x0,75 mm2 con diametro esterno massimo di 8 mm. Accesso alla morsettiera elettrica Svitare le due viti “A” poste sulla parte superiore del cruscotto e rimuovere lo sportellino “B“. fig. 4 - Accesso alla morsettiera 3.6 Collegamento alla canna fumaria L’apparrecchio deve essere collegato ad una canna fumaria progettata e costruita nel rispetto delle norme vigenti. Il condotto tra caldaia e canna fumaria deve essere di ma- teriale adatto allo scopo, resistente cioè alla temperatura ed alla corrosione. Nei punti di giunzione si raccomanda di curare la tenuta e di isolare termicamente tutto il condotto tra caldaia e camino, per evitare la formazione di condensa. 4. SERVIZIO E MANUTENZIONE Tutte le operazioni di regolazione, trasformazione, messa in servizio, manutenzione de- scritte di seguito, devono essere effettuate solo da Personale Qualificato e di sicura qua- lificazione (in possesso dei requisiti tecnici professionali previsti dalla normativa vigente) come il personale del Servizio Tecnico Assistenza Clienti di Zona. FERROLI declina ogni responsabilità per danni a cose e/o persone derivanti dalla ma- nomissione dell’apparecchio da parte di persone non qualificate e non autorizzate. 4.1 Regolazioni Regolazione bruciatore Il rendimento della caldaia ed il corretto funzionamento dipendono soprattutto dall'accu- ratezza delle regolazioni del bruciatore. Seguire attentamente le istruzioni del relativo produttore. I bruciatori a due stadi devono avere il primo stadio regolato ad una potenza non inferiore alla potenza minima nominale della caldaia. La potenza del secondo stadio non deve essere superiore a quella nominale massima della caldaia. 4.2 Messa in servizio B Verifiche da eseguire alla prima accensione, e dopo tutte le operazioni di ma- nutenzione che abbiano comportato la disconnessione dagli impianti o un inter- vento su organi di sicurezza o parti della caldaia: Prima di accendere la caldaia • Aprire le eventuali valvole di intercettazione tra caldaia ed impianti. • Verificare la tenuta dell’impianto combustibile. • Verificare la corretta precarica del vaso di espansione • Riempire l’impianto idraulico ed assicurare un completo sfiato dell’aria contenuta nella caldaia e nell’impianto, aprendo la valvola di sfiato aria posta nella caldaia e le eventuali valvole di sfiato sull’impianto. • Verificare che non vi siano perdite di acqua nell’impianto, nei circuiti acqua sanitaria, nei collegamenti o in caldaia. • Verificare l’esatto collegamento dell’impianto elettrico e la funzionalità dell’impianto di terra • Verificare che non vi siano liquidi o materiali infiammabili nelle immediate vicinanze della caldaia Verifiche durante il funzionamento • Accendere l’apparecchio come descritto nella sez. 2.3. • Assicurarsi della tenuta del circuito del combustibile e degli impianti acqua. • Controllare l’efficienza del camino e condotti aria-fumi durante il funzionamento del- la caldaia. • Controllare che la circolazione dell’acqua, tra caldaia ed impianti, avvenga corretta- mente. • Verificare la buona accensione della caldaia, effettuando diverse prove di accensio- ne e spegnimento, per mezzo del termostato ambiente o del comando remoto. • Assicurarsi che il consumo del combustibile indicato al contatore, corrisponda a quello indicato nella tabella dati tecnici alla sez. 5.3. • Verificare che la porta bruciatore e camera fumo siano a tenuta. • Verificare che il bruciatore funzioni correttamente. Questo controllo va fatto con gli appositi strumenti seguendo le istruzioni del costruttore. 4.3 Manutenzione Controllo periodico Per mantenere nel tempo il corretto funzionamento dell’apparecchio, è necessario far eseguire da personale qualificato un controllo annuale che preveda le seguenti verifiche: • I dispositivi di comando e di sicurezza devono funzionare correttamente. • Il circuito di evacuazione fumi deve essere in perfetta efficienza. • Controllare che non ci siano eventuali occlusioni o ammaccature nei tubi di alimen- tazione e ritorno del combustibile. • Effettuare la pulizia del filtro di linea di aspirazione del combustibile. • Rilevare il corretto consumo di combustibile • Effettuare la pulizia della testa di combustione nella zona di uscita del combustibile, sul disco di turbolenza. • Lasciare funzionare il bruciatore a pieno regime per circa dieci minuti, quindi effet- tuare un'analisi della combustione verificando: - Le corrette tarature di tutti gli elementi indicati nel presente manuale - Temperature dei fumi al camino - Contenuto della percentuale di CO2 • I condotti ed il terminale aria-fumi devono essere liberi da ostacoli e non presentare perdite • Il bruciatore e lo scambiatore devono essere puliti ed esenti da incrostazioni. Per l’eventuale pulizia non usare prodotti chimici o spazzole di acciaio. • Gli impianti combustibile e acqua devono essere a tenuta. • La pressione dell’acqua dell’impianto a freddo deve essere di circa 1 bar; in caso contrario riportarla a questo valore. • La pompa di circolazione non deve essere bloccata. • Il vaso d’espansione (non fornito) deve essere carico. A L’eventuale pulizia del mantello, del cruscotto e delle parti estetiche della cal- daia può essere eseguita con un panno morbido e umido eventualmente imbe- vuto con acqua saponata. Tutti i detersivi abrasivi e i solventi sono da evitare. Pulizia della caldaia 1. Togliere l’alimentazione elettrica alla caldaia. 2. Togliere il pannello anteriore superiore e quello inferiore. 3. Aprire la porta svitando i relativi pomelli. 4. Pulire l’interno della caldaia e tutto il percorso dei fumi di scarico, tramite uno sco- volo o con aria compressa. 5. Richiudere infine la porta, fissandola con il relativo pomello. Per la pulizia del bruciatore, consultare le istruzioni della Ditta Costruttrice. 4.4 Risoluzione dei problemi Anomalie Possono verificarsi due condizioni di blocco ripristinabili dall’utente: A Blocco del bruciatore segnalato dall’apposita spia. Riferirsi al manuale del bru- ciatore. B Intervento del termostato di sicurezza che avviene quando la temperatura in caldaia raggiunge un valore oltre al quale può crearsi una condizione di perico- lo. Per ripristinare il funzionamento, svitare il tappo 3 di fig. 1 e premere il pul- sante di riarmo sottostante. Se il problema si ripete, richiedere l’intervento di Personale Qualificato o del centro as- sistenza. In caso di guasto e/o cattivo funzionamento dell’apparecchio, disattivarlo, astenendosi da qualsiasi tentativo di riparazione o di intervento diretto. Rivolgersi esclusivamente a personale professionalmente qualificato ed autorizzato.    

Страница 3 PDF

Страница 4

ATLAS 4 IT cod. 3540S123 - 07/2010 (Rev. 00) 5. CARATTERISTICHE E DATI TECNICI 5.1 Dimensioni, attacchi e componenti principali fig. 5 - Dimensionale, attacchi e componenti principali a1 Mandata impianto - 1” 1/2” a2 Ritorno impianto - 1” 1/2” a3 Scarico impianto di riscaldamento - 1/2” a4 Attacco camino a5 Attacco bruciatore 34 Bulbo temperatura riscaldamento e sicurezza 5.2 Perdita di carico Perdita di carico lato acqua fig. 6 - Perdite di carico A mbar B Portata l/h 5.3 Tabella dati tecnici Modello C mm a4 Ø mm a5 Ø mm ATLAS 32 400 120÷130 115 ATLAS 47 500 120÷130 115 ATLAS 62 600 120÷130 115 ATLAS 78 700 120÷130 115 ATLAS 95 800 120÷130 115                     Modello ATLAS 32 ATLAS 47 ATLAS 62 ATLAS 78 ATLAS 95 Numero elementi n° 3 4 5 6 7 Portata termica max kW 34.9 51.6 67.7 85.6 103.2 (Q) Portata termica min kW 17.0 34.3 45.8 59.0 70.8 (Q) Potenza termica max riscaldamento kW 32 47 62 78 95 (P) Potenza termica min riscaldamento kW 16 32 43 55 66 (P) Rendimento Pmax (80-60°C) % 91.7 91.1 91.5 91.1 92 Rendimento 30% % 94.3 93.5 94.0 93.5 93.8 Classe efficienza direttiva 92/42 EEC Pressione max esercizio riscaldamento bar 6 6 6 6 6 (PMS) Pressione min esercizio riscaldamento bar 0.8 0.8 0.8 0.8 0.8 Temperatura max riscaldamento °C 95 95 95 95 95 (tmax) Contenuto acqua riscaldamento l 18 23 28 33 38 Grado protezione IP X0D X0D X0D X0D X0D Tensione di alimentazione V/Hz 230/50 230/50 230/50 230/50 230/50 Peso a vuoto kg 127 166 205 244 283 Lunghezza camera di combustione mm 350 450 550 650 750 Diametro camera di combustione mm 300 300 300 300 300 Perdita di carico lato fumi mbar 0.2 0.27 0.4 0.4 0.63                 

Страница 4 PDF

Страница 5

ATLAS 5 IT cod. 3540S123 - 07/2010 (Rev. 00) 6 5.4 Schema elettrico Schema elettrico di principio ATLAS 32-78 fig. 7 - Schema elettrico di principio ATLAS 32-78 Legenda fig. 7 e fig. 8 32 Circolatore riscaldamento (non fornito) 49 Termostato di sicurezza 72 Termostato ambiente (non fornito) 63 Termostato di regolazione caldaia 98 Interruttore 211 Connettore bruciatore (non fornito) Schema elettrico di allacciamento ATLAS 32-78 fig. 8 - Schema elettrico di allacciamento ATLAS 32-78 Schema elettrico di principio ATLAS 95 fig. 9 - Schema elettrico di principio ATLAS 95 Legenda fig. 9 e fig. 10 32 Circolatore riscaldamento (non fornito) 49 Termostato di sicurezza 72 Termostato ambiente (non fornito) 98 Interruttore 170 Termostato di regolazione caldaia 1° Stadio 171 Termostato di regolazione caldaia 2° Stadio 211 Connettore bruciatore (non fornito) Schema elettrico di allacciamento ATLAS 95 fig. 10 - Schema elettrico di allacciamento ATLAS 95          

Страница 5 PDF

Страница 6

ATLAS 17 EN cod. 3540S123 - 07/2010 (Rev. 00) EN 1. GENERAL INSTRUCTIONS • Carefully read the instructions contained in this instruction booklet. • After boiler installation, inform the user regarding its operation and give him this manual, which is an integral and essential part of the product and must be kept with care for future reference. • Installation and maintenance must be carried out by professionally qualified person- nel, according to current regulations and the manufacturer's instructions. Do not car- ry out any operation on the sealed control parts. • Incorrect installation or inadequate maintenance can result in damage or injury. The Manufacturer declines any liability for damage due to errors in installation and use or failure to follow the instructions. • Before carrying out any cleaning or maintenance operation, disconnect the unit from the power supply using the system switch and/or the special cut-off devices. • In case of a fault and/or poor operation, deactivate the unit and do not attempt to repair it or directly intervene. Contact professionally qualified personnel. Repair/re- placement of the products must only be carried out by professionally qualified using original spare parts. Failure to comply with the above could affect the safety of the unit. • This unit must only be used for its intended purpose. Any other use is considered improper and therefore dangerous. • The packing materials are potentially hazardous and must not be left within the reach of children. • The images given in this manual are a simplified representation of the product. In this representation there may be slight and insignificant differences with respect to the product supplied. 2. OPERATING INSTRUCTIONS 2.1 Introduction Dear Customer, Thank you for choosing a FERROLI boiler featuring advanced design, cutting-edge technology, high reliability and quality construction. Please read this manual carefully since it provides important information on safe installation, use and maintenance. ATLAS is a high-efficiency heat generator for the production of heating hot water, suita- ble for operation with blown oil or gas burners. The boiler shell consists of cast iron ele- ments, assembled with steel stays and double cones, whose profile is specially designed with optimum division of the fins, offering high thermal efficiency and therefore high en- ergy-saving. 2.2 Control panel fig. 1 - Control panel for models ATLAS 32-78 fig. 2 - Control panel for models ATLAS 95 Key 1 = Thermometer 2 = Ignition switch 3 = Manual reset safety thermostat 4 = 1st stage temperature control knob 5 = 2nd stage temperature control knob 2.3 Turning on and off Boiler lighting Open the fuel shutoff valves. Switch on the power to the unit. Press button 2 of fig. 1 to feed the boiler and burner. Refer to the burner manual for op- eration. Turning the boiler off For brief shutdown periods just press button 2 of fig. 1 on the control panel , bringing it to position “0”. For long shutdown periods, as well as operating button 2 also close the fuel shutoff valve . To avoid damage caused by freezing during long shutdowns in winter, add a suitable antifreeze to the system or completely drain the system. 2.4 Adjustments Heating temperature setting Set the required system temperature with the control thermostat 4 of fig. 1. For the model ATLAS 95, with the control thermostat 5 then set the temperature of the 2nd stage to a temperature 10°C lower than that of the 1st stage. A IMPORTANT: The temperature setting of the 2nd stage must always be lower than that of the 1st stage.. fig. 3 - Temperature adjustment for model ATLAS 95 Room temperature adjustment (with optional room thermostat) Using the room thermostat, set the temperature desired in the rooms. If the room ther- mostat is not installed the boiler will keep the heating system at its setpoint temperature. 3. INSTALLATION 3.1 General Instructions BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSON- NEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRESCRIPTIONS OF NA- TIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP. 3.2 Place of installation The boiler must be installed in a special room with ventilation openings towards the out- side in conformity with current regulations. If there are several burners or extraction units that can work together in the same room, the ventilation openings must be sized for si- multaneous operation of all the units. The place of installation must be free of flammable objects or materials, corrosive gases, volatile substances or dusts which, sucked by the burner fan, can obstruct the pipes inside the burner or the combustion head. The room must be dry and not exposed to rain, snow or frost. A If the unit is enclosed in a cabinet or mounted alongside, a space must be pro- vided for removing the casing and for normal maintenance operations. In par- ticular, after boiler installation with burner on the front door, make sure the front door can open freely without the burner striking walls or other obstacles. 3.3 Plumbing connections The heating capacity of the unit must be previously established by calculating the build- ing's heat requirement according to the current regulations. The system must be provid- ed with all the components for correct and regular operation. It is advisable to install shutoff valves between the boiler and heating system allowing the boiler to be isolated from the system if necessary. B The safety valve outlet must be connected to a funnel or collection pipe to pre- vent water spurting onto the floor in case of overpressure in the heating circuit. Otherwise, if the discharge valve cuts in and floods the room, the boiler manu- facturer cannot be held liable. Do not use the water system pipes to earth electrical appliances. Before installation, carefully wash all the pipes of the system to remove any residuals or impurities that could affect proper operation of the unit. Carry out the relevant connections according to the diagram in and thecap. 5 symbols given on the unit. A The unit is not supplied with an expansion tank; its connection must therefore be carried out by the Installer. The pressure in the system, when cold, must be 1 bar. Water system characteristics In the presence of water harder than 25° Fr (1°F = 10ppm CaCO3), use suitably treated water in order to avoid possible scaling in the boiler. Treatment must not reduce the hard- ness to values below 15°F (Decree 236/88 for uses of water intended for human con- sumption). Treatment of the water used is indispensable in case of very large systems or with frequent introduction of replenishing water in the system. B If water softeners are installed at the boiler cold water inlet, make sure not to reduce the water hardness too much, as this could cause early deterioration of the magnesium anode in the hot water tank. Antifreeze system, antifreeze fluids, additives and inhibitors If it becomes necessary, it is permissible to use antifreeze fluid, additives and inhibitors only if the manufacturer of these fluids or additives guarantees they are suitable for this use and cause no damage to the heat exchanger or other components and/or materials of the boiler unit and system. It is prohibited to use generic antifreeze fluid, additives or inhibitors that are not expressly suited for use in heating systems and compatible with the materials of the boiler unit and system. 3.4 Burner connection An oil or gas burner, with blown air for pressured furnaces, can be used if its operation characteristics are suitable for the size of the boiler furnace and its overpressure. The choice of burner must be made beforehand, following the manufacturer's instructions, according to the work range, fuel consumption and pressures, as well as the length of the firebox. Install the burner in compliance with the Manufacturer's instructions.                                        

Страница 6 PDF

Страница 7

ATLAS 18 EN cod. 3540S123 - 07/2010 (Rev. 00) 3.5 Electrical connections Connection to the electrical grid B The unit's electrical safety is only guaranteed when correctly connected to an efficient earthing system executed according to current safety standards. Have the efficiency and suitability of the earthing system checked by professionally qualified personnel. The manufacturer is not responsible for any damage caused by failure to earth the system. Also make sure that the electrical system is adequate for the maximum power absorbed by the unit, as specified on the boiler dataplate. The boiler is prewired and provided with a Y-cable and plug for connection to the elec- tricity line. The connections to the grid must be made with a permanent connection and equipped with a bipolar switch whose contacts have a minimum opening of at least 3 mm, interposing fuses of max. 3A between the boiler and the line. It is important to re- spect the polarities (LINE: brown wire / NEUTRAL: blue wire / EARTH: yellow-green wire) in making connections to the electrical line. During installation or when changing the power cable, the earth wire must be left 2 cm longer than the others. B The user must never change the unit's power cable. If the cable gets damaged, switch off the unit and have it changed solely by professionally qualified person- nel. If changing the electric power cable, use solely “HAR H05 VV-F” 3x0.75 mm2 cable with a maximum outside diameter of 8 mm. Accessing the electrical terminal block Undo the two screws “A” located on the top part of the control panel and remove the cover “B“. fig. 4 - Accessing the terminal block 3.6 Connection to the flue The unit must be connected to a flue designed and built in compliance with current reg- ulations. The pipe between the boiler and flue must be made from material suitable for the purpose, i.e. heat and corrosion resistant. Ensure the seal at the joints and insulate the entire pipe between boiler and flue, to prevent the formation of condensate. 4. SERVICE AND MAINTENANCE All adjustment, conversion, start-up and maintenance operations described below must only be carried out by Qualified Personnel (meeting the professional technical requirements prescribed by current regulations) such as those of the Local After-Sales Technical Service. FERROLI declines any liability for damage and/or injury caused by unqualified and unauthorised people tampering with the unit. 4.1 Adjustments Burner adjustment Boiler efficiency and correct operation depend above all on accurate burner adjustments. Carefully follow the Manufacturer's instructions. The two-stage burners must have the first stage adjusted to a power level not below the boiler's rated min. power. The power of the second stage must not be higher than the boiler's rated max. power. 4.2 Start-up B Checks to be made at first lighting and after all maintenance operations that involved dis- connecting from the systems or an operation on safety devices or parts of the boiler: Before lighting the boiler • Open any on-off valves between the boiler and the systems. • Check the seal of the fuel system. • Check correct prefilling of the expansion tank. • Fill the water system and make sure that all air contained in the boiler and the system has been vented, by opening the air valve on the boiler and any air valves on the system. • Make sure there are no water leaks in the system, domestic hot water circuits, connections or boiler. • Check correct connection of the electrical system and efficiency of the earthing system • Make sure there are no flammable liquids or materials in the immediate vicinity of the boiler Checks during operation • Light the unit on as described in sec. 2.3. • Make sure the fuel circuit and water systems are tight. • Check the efficiency of the flue and air/fume ducts while the boiler is working. • Make sure the water is circulating properly between the boiler and the systems. • Check proper lighting of the boiler by doing several tests, turning it on and off with the room thermostat or remote control. • Make sure the fuel consumption indicated on the meter matches that given in the technical data table on sec. 5.3. • Make sure the fumebox and burner door are tight. • Make sure the burner works properly. This check must be made with the special in- struments, following the manufacturer's instructions. 4.3 Maintenance Periodical check To ensure correct operation of the unit over time, have qualified personnel carry out a yearly check, providing for the following: • The control and safety devices must function correctly. • The fume evacuation circuit must be perfectly efficient. • Make sure there are no obstructions or dents in the fuel supply and return pipes. • Clean the filter of the fuel suction line. • Measure the correct fuel consumption • Clean the combustion head in the fuel outlet zone, on the swirl disc. • Leave the burner on at max. for about ten minutes, then analyse the combustion, checking: - Correct setting of the elements specified in this manual. - Temperatures of fumes at the flue - CO2 percentage content • The air/fume terminal and ducts must be free of obstructions and leaks • The burner and exchanger must be clean and free of deposits. For cleaning do not use chemical products or wire brushes. • The fuel and water systems must be tight. • The water pressure in the system when cold must be approx. 1 bar; otherwise bring it to that value. • The circulating pump must not be blocked. • The expansion tank (not supplied) must be filled. A The boiler casing, control panel and aesthetic parts can be cleaned with a soft damp cloth, if necessary soaked in soapy water. Do not use any abrasive de- tergents and solvents. Boiler cleaning 1. Disconnect the power supply to the boiler. 2. Remove the front top and bottom panel. 3. Open the door by undoing the knobs. 4. Clean the inside of the boiler and the entire path of exhaust fumes, using a tube brush or compressed air. 5. Then close the door, securing it with the knob. To clean the burner, refer to the Manufacturer's instructions. 4.4 Troubleshooting Fault Two shutdown conditions resettable by the user can occur : A Burner shutdown signalled by the special indicator. Refer to the burner manual. B Cutting in of the safety thermostat, which occurs when the boiler temperature reaches a value beyond which a dangerous condition may be created. To re- store operation, unscrew cap 3 of fig. 1 and press the reset button below. If the problem persists, request the assistance of Qualified Personnel or the After-Sales Centre. In case of a fault and/or poor operation, deactivate the unit, do not try to fix the problem or directly carry out any operation. Contact authorised and professionally qualified per- sonnel.    

Страница 7 PDF

Страница 8

ATLAS 19 EN cod. 3540S123 - 07/2010 (Rev. 00) 5. TECHNICAL DATA AND CHARACTERISTICS 5.1 Dimensions, connections and main components fig. 5 - Dimensions, connections and main components a1 System delivery - 1” 1/2” a2 System return - 1” 1/2” a3 Heating system drain - 1/2” a4 Flue connection a5 Burner connection 34 Safety and heating temperature bulb 5.2 Pressure loss Pressure loss water side fig. 6 - Pressure loss A mbar B Flowrate l/h 5.3 Technical data table Model C mm a4 Ø mm a5 Ø mm ATLAS 32 400 120÷130 115 ATLAS 47 500 120÷130 115 ATLAS 62 600 120÷130 115 ATLAS 78 700 120÷130 115 ATLAS 95 800 120÷130 115                     Model ATLAS 32 ATLAS 47 ATLAS 62 ATLAS 78 ATLAS 95 Number of elements n° 3 4 5 6 7 Max. heating capacity kW 34.9 51.6 67.7 85.6 103.2 (Q) Min. heating capacity kW 17.0 34.3 45.8 59.0 70.8 (Q) Max. heat output in heating kW 32 47 62 78 95 (P) Min. heat output in heating kW 16 32 43 55 66 (P) Efficiency Pmax (80-60°C) % 91.7 91.1 91.5 91.1 92 Efficiency 30% % 94.3 93.5 94.0 93.5 93.8 Efficiency class Directive 92/42 EEC Max. working pressure in heating bar 6 6 6 6 6 (PMS) Min. working pressure in heating bar 0.8 0.8 0.8 0.8 0.8 Max. heating temperature °C 95 95 95 95 95 (tmax) Heating water content l 18 23 28 33 38 Protection rating IP X0D X0D X0D X0D X0D Power supply voltage V/Hz 230/50 230/50 230/50 230/50 230/50 Empty weight kg 127 166 205 244 283 Combustion chamber length mm 350 450 550 650 750 Combustion chamber diameter mm 300 300 300 300 300 Pressure loss fume side mbar 0.2 0.27 0.4 0.4 0.63                 

Страница 8 PDF

Страница 9

ATLAS 20 EN cod. 3540S123 - 07/2010 (Rev. 00) 5.4 Wiring diagram Main wiring diagram ATLAS 32-78 fig. 7 - Main wiring diagram ATLAS 32-78 Key fig. 7 and fig. 8 32 Heating circulating pump (not supplied) 49 Safety thermostat 72 Room thermostat (not supplied) 63 Boiler control thermostat 98 Switch 211 Burner connector (not supplied) Electrical connection diagram ATLAS 32-78 fig. 8 - Electrical connection diagram ATLAS 32-78 Main wiring diagram ATLAS 95 fig. 9 - Main wiring diagram ATLAS 95 Key fig. 9 and fig. 10 32 Heating circulating pump (not supplied) 49 Safety thermostat 72 Room thermostat (not supplied) 98 Switch 170 1st Stage boiler control thermostat 171 2nd Stage boiler control thermostat 211 Burner connector (not supplied) Electrical connection diagram ATLAS 95 fig. 10 - Electrical connection diagram ATLAS 95          

Страница 9 PDF

Страница 10

ATLAS 33 RU cod. 3540S123 - 07/2010 (Rev. 00) RU 1. ɈȻɓɂȿ ɍɄȺɁȺɇɂʇ ɉɈ ɌȿɏɇɂɄȿ ȻȿɁɈɉȺɋɇɈɋɌɂ • ȼɧɢɦɚɬɟɥɶɧɨ ɩɪɨɱɢɬɚɣɬɟ ɩɪɟɞɭɩɪɟɠɞɟɧɢɹ, ɫɨɞɟɪɠɚɳɢɟɫɹ ɜ ɧɚɫɬɨɹɳɟɦ ɪɭɤɨɜɨɞɫɬɜɟ. • ɉɨɫɥɟ ɭɫɬɚɧɨɜɤɢ ɤɨɬɥɚ ɩɪɨɢɧɮɨɪɦɢɪɭɣɬɟ ɩɨɥɶɡɨɜɚɬɟɥɹ ɨ ɩɪɢɧɰɢɩɚɯ ɪɚɛɨɬɵ ɚɝɪɟɝɚɬɚ ɢ ɩɟɪɟɞɚɣɬɟ ɟɦɭ ɧɚɫɬɨɹɳɟɟ ɪɭɤɨɜɨɞɫɬɜɨ; ɨɧɨ ɹɜɥɹɟɬɫɹ ɫɭɳɟɫɬɜɟɧɧɨɣ ɢ ɧɟɨɬɴɟɦɥɟɦɨɣ ɱɚɫɬɶɸ ɢɡɞɟɥɢɹ ɢ ɞɨɥɠɧɨ ɛɟɪɟɠɧɨ ɫɨɯɪɚɧɹɬɶɫɹ ɞɥɹ ɢɫɩɨɥɶɡɨɜɚɧɢɹ ɜ ɛɭɞɭɳɟɦ. • ɍɫɬɚɧɨɜɤɚ ɢ ɬɟɯɧɢɱɟɫɤɨɟ ɨɛɫɥɭɠɢɜɚɧɢɟ ɤɨɬɥɚ ɞɨɥɠɧɵ ɩɪɨɢɡɜɨɞɢɬɶɫɹ ɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɦ ɩɟɪɫɨɧɚɥɨɦ ɩɪɢ ɫɨɛɥɸɞɟɧɢɢ ɞɟɣɫɬɜɭɸɳɢɯ ɧɨɪɦ ɢ ɜ ɫɨɨɬɜɟɬɫɬɜɢɢ ɫ ɭɤɚɡɚɧɢɹɦɢ ɢɡɝɨɬɨɜɢɬɟɥɹ. Ɂɚɩɪɟɳɚɟɬɫɹ ɜɵɩɨɥɧɹɬɶ ɤɚɤɢɟ-ɥɢɛɨ ɪɚɛɨɬɵ ɧɚ ɨɩɥɨɦɛɢɪɨɜɚɧɧɵɯ ɪɟɝɭɥɢɪɨɜɨɱɧɵɯ ɭɫɬɪɨɣɫɬɜɚɯ. • ɇɟɩɪɚɜɢɥɶɧɚɹ ɭɫɬɚɧɨɜɤɚ ɢɥɢ ɧɟɧɚɞɥɟɠɚɳɟɟ ɬɟɯɧɢɱɟɫɤɨɟ ɨɛɫɥɭɠɢɜɚɧɢɟ ɦɨɝɭɬ ɩɪɢɜɟɫɬɢ ɤ ɦɚɬɟɪɢɚɥɶɧɨɦɭ ɭɳɟɪɛɭ ɢɥɢ ɬɪɚɜɦɚɦ ɥɸɞɟɣ ɢ ɠɢɜɨɬɧɵɯ. ɂɡɝɨɬɨɜɢɬɟɥɶ ɧɟ ɧɟɫɟɬ ɧɢɤɚɤɨɣ ɨɬɜɟɬɫɬɜɟɧɧɨɫɬɢ ɡɚ ɭɳɟɪɛ, ɫɜɹɡɚɧɧɵɣ ɫ ɨɲɢɛɨɱɧɵɦɢ ɭɫɬɚɧɨɜɤɨɣ ɢ ɷɤɫɩɥɭɚɬɚɰɢɟɣ ɚɩɩɚɪɚɬɚ, ɚ ɬɚɤɠɟ ɫ ɧɟɫɨɛɥɸɞɟɧɢɟɦ ɩɪɟɞɨɫɬɚɜɥɟɧɧɵɯ ɢɦ ɢɧɫɬɪɭɤɰɢɣ. • ɉɟɪɟɞ ɜɵɩɨɥɧɟɧɢɟɦ ɥɸɛɨɣ ɨɩɟɪɚɰɢɢ ɩɨ ɱɢɫɬɤɟ ɢɥɢ ɬɟɯɧɢɱɟɫɤɨɦɭ ɨɛɫɥɭɠɢɜɚɧɢɸ ɨɬɫɨɟɞɢɧɢɬɟ ɚɝɪɟɝɚɬ ɨɬ ɫɟɬɢ ɷɥɟɤɬɪɨɩɢɬɚɧɢɹ ɫ ɩɨɦɨɳɶɸ ɝɥɚɜɧɨɝɨ ɪɭɛɢɥɶɧɢɤɚ ɢ/ɢɥɢ ɩɪɟɞɭɫɦɨɬɪɟɧɧɵɯ ɞɥɹ ɷɬɨɣ ɰɟɥɢ ɨɬɫɟɱɧɵɯ ɭɫɬɪɨɣɫɬɜ. • ȼ ɫɥɭɱɚɟ ɧɟɢɫɩɪɚɜɧɨɣ ɢ/ɢɥɢ ɧɟɧɨɪɦɚɥɶɧɨɣ ɪɚɛɨɬɵ ɚɝɪɟɝɚɬɚ, ɜɵɤɥɸɱɢɬɟ ɟɝɨ ɢ ɜɨɡɞɟɪɠɢɬɟɫɶ ɨɬ ɥɸɛɨɣ ɩɨɩɵɬɤɢ ɫɚɦɨɫɬɨɹɬɟɥɶɧɨ ɨɬɪɟɦɨɧɬɢɪɨɜɚɬɶ ɢɥɢ ɭɫɬɪɚɧɢɬɶ ɩɪɢɱɢɧɭ ɧɟɢɫɩɪɚɜɧɨɫɬɢ. ȼ ɬɚɤɢɯ ɫɥɭɱɚɹɯ ɨɛɪɚɳɚɣɬɟɫɶ ɢɫɤɥɸɱɢɬɟɥɶɧɨ ɤ ɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɦ ɫɩɟɰɢɚɥɢɫɬɚɦ. ȼɨɡɦɨɠɧɵɟ ɨɩɟɪɚɰɢɢ ɩɨ ɪɟɦɨɧɬɭ-ɡɚɦɟɧɟ ɤɨɦɩɥɟɤɬɭɸɳɢɯ ɞɨɥɠɧɵ ɜɵɩɨɥɧɹɬɶɫɹ ɬɨɥɶɤɨ ɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɦɢ ɫɩɟɰɢɚɥɢɫɬɚɦɢ ɫ ɢɫɩɨɥɶɡɨɜɚɧɢɟɦ ɢɫɤɥɸɱɢɬɟɥɶɧɨ ɨɪɢɝɢɧɚɥɶɧɵɯ ɡɚɩɱɚɫɬɟɣ. ɇɟɫɨɛɥɸɞɟɧɢɟ ɜɫɟɝɨ ɜɵɲɟɭɤɚɡɚɧɧɨɝɨ ɦɨɠɟɬ ɧɚɪɭɲɢɬɶ ɛɟɡɨɩɚɫɧɨɫɬɶ ɪɚɛɨɬɵ ɚɝɪɟɝɚɬɚ. • ɇɚɫɬɨɹɳɢɣ ɚɝɪɟɝɚɬ ɫɥɟɞɭɟɬ ɢɫɩɨɥɶɡɨɜɚɬɶ ɬɨɥɶɤɨ ɩɨ ɩɪɟɞɭɫɦɨɬɪɟɧɧɨɦɭ ɧɚɡɧɚɱɟɧɢɸ. Ʌɸɛɨɟ ɩɪɨɱɟɟ ɢɫɩɨɥɶɡɨɜɚɧɢɟ ɫɥɟɞɭɟɬ ɫɱɢɬɚɬɶ ɧɟɩɪɚɜɢɥɶɧɵɦ ɢ, ɫɥɟɞɨɜɚɬɟɥɶɧɨ, ɩɪɟɞɫɬɚɜɥɹɸɳɢɦ ɨɩɚɫɧɨɫɬɶ. • ɍɩɚɤɨɜɨɱɧɵɟ ɦɚɬɟɪɢɚɥɵ ɹɜɥɹɸɬɫɹ ɢɫɬɨɱɧɢɤɨɦ ɩɨɬɟɧɰɢɚɥɶɧɨɣ ɨɩɚɫɧɨɫɬɢ ɢ ɧɟ ɞɨɥɠɧɵ ɛɵɬɶ ɨɫɬɚɜɥɟɧɵ ɜ ɦɟɫɬɚɯ, ɞɨɫɬɭɩɧɵɯ ɞɟɬɹɦ. • ɉɪɢɜɟɞɟɧɧɵɟ ɜ ɧɚɫɬɨɹɳɟɦ ɪɭɤɨɜɨɞɫɬɜɟ ɢɡɨɛɪɚɠɟɧɢɹ ɞɚɸɬ ɭɩɪɨɳɟɧɧɨɟ ɩɪɟɞɫɬɚɜɥɟɧɢɟ ɨɛ ɚɝɪɟɝɚɬɟ ɢ ɦɨɝɭɬ ɫɨɞɟɪɠɚɬɶ ɧɟɫɭɳɟɫɬɜɟɧɧɵɟ ɨɬɥɢɱɢɹ ɨɬ ɩɨɫɬɚɜɥɟɧɧɨɝɨ ɢɡɞɟɥɢɹ. 2. ɂɇɋɌɊɍɄɐɂɂ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ 2.1 ɉɪɟɞɢɫɥɨɜɢɟ ɍɜɚɠɚɟɦɵɣ ɩɨɤɭɩɚɬɟɥɶ, Ȼɥɚɝɨɞɚɪɢɦ ȼɚɫ ɡɚ ɬɨ, ɱɬɨ ȼɵ ɜɵɛɪɚɥɢ ɤɨɬɟɥ FERROLI, ɢɦɟɸɳɢɣ ɫɚɦɭɸ ɫɨɜɪɟɦɟɧɧɭɸ ɤɨɧɫɬɪɭɤɰɢɸ, ɜɵɩɨɥɧɟɧɧɵɣ ɩɨ ɩɟɪɟɞɨɜɵɦ ɬɟɯɧɨɥɨɝɢɹɦ ɢ ɨɬɥɢɱɚɸɳɢɣɫɹ ɜɵɫɨɤɨɣ ɧɚɞɟɠɧɨɫɬɶɸ ɢ ɤɚɱɟɫɬɜɨɦ. ɉɪɨɫɢɦ ȼɚɫ ɜɧɢɦɚɬɟɥɶɧɨ ɩɪɨɱɢɬɚɬɶ ɧɚɫɬɨɹɳɟɟ ɪɭɤɨɜɨɞɫɬɜɨ, ɬ.ɤ. ɜ ɧɟɦ ɩɪɢɜɨɞɹɬɫɹ ɜɚɠɧɵɟ ɭɤɚɡɚɧɢɹ ɩɨ ɛɟɡɨɩɚɫɧɨɫɬɢ ɭɫɬɚɧɨɜɤɢ, ɷɤɫɩɥɭɚɬɚɰɢɢ ɢ ɬɟɯɧɢɱɟɫɤɨɝɨ ɨɛɫɥɭɠɢɜɚɧɢɹ ɚɝɪɟɝɚɬɚ. ATLAS Ʉɨɬɟɥ ɩɪɟɞɫɬɚɜɥɹɟɬ ɫɨɛɨɣ ɬɟɩɥɨɜɨɣ ɝɟɧɟɪɚɬɨɪ ɞɥɹ ɨɬɨɩɥɟɧɢɹ ɢ Ƚȼɋ, ɜ ɤɨɬɨɪɨɦ ɦɨɝɭɬ ɛɵɬɶ ɢɫɩɨɥɶɡɨɜɚɧɵ ɠɢɞɤɨɬɨɩɥɢɜɧɵɟ ɢɥɢ ɝɚɡɨɜɵɟ ɝɨɪɟɥɨɱɧɵɟ ɭɫɬɪɨɣɫɬɜɚ ɫ ɩɨɞɞɭɜɨɦ. Ʉɨɪɩɭɫ ɤɨɬɥɚ ɫɨɛɪɚɧ ɢɡ ɱɭɝɭɧɧɵɯ ɷɥɟɦɟɧɬɨɜ, ɫɨɟɞɢɧɟɧɧɵɯ ɦɟɠɞɭ ɫɨɛɨɣ ɞɜɭɯɤɨɧɭɫɧɵɦɢ ɤɨɥɶɰɚɦɢ ɢ ɫɬɹɠɧɵɦɢ ɛɨɥɬɚɦɢ ɢɡ ɫɬɚɥɢ. ɗɥɟɦɟɧɬɵ ɫ ɨɫɨɛɵɦ ɩɪɨɮɢɥɟɦ ɢ ɫɩɟɰɢɚɥɶɧɵɦ ɪɚɫɩɨɥɨɠɟɧɢɟɦ ɪɟɛɟɪ ɨɛɟɫɩɟɱɢɜɚɸɬ ɞɨɫɬɢɠɟɧɢɟ ɜɵɫɨɤɨɝɨ ɬɟɪɦɢɱɟɫɤɨɝɨ ɤɩɞ ɢ ɡɧɚɱɢɬɟɥɶɧɭɸ ɷɤɨɧɨɦɢɸ ɷɧɟɪɝɢɢ. 2.2 ɉɚɧɟɥɶ ɭɩɪɚɜɥɟɧɢɹ ɪɢɫ. 1 - ɉɚɧɟɥɶ ɭɩɪɚɜɥɟɧɢɹ ɦɨɞɟɥɟɣ ATLAS 32-78 ɪɢɫ. 2 - ɉɚɧɟɥɶ ɭɩɪɚɜɥɟɧɢɹ ɦɨɞɟɥɟɣ ATLAS 95 Ʌɟɝɟɧɞɚ 1 = Ɍɟɪɦɨɦɟɬɪ 2 = Ƚɥɚɜɧɵɣ ɜɵɤɥɸɱɚɬɟɥɶ 3 = ɉɪɟɞɨɯɪɚɧɢɬɟɥɶɧɵɣ ɬɟɪɦɨɫɬɚɬ ɫ ɪɭɱɧɵɦ ɜɨɡɜɪɚɬɨɦ ɜ ɪɚɛɨɱɟɟ ɫɨɫɬɨɹɧɢɟ 4 = Ɋɭɱɤɚ ɞɥɹ ɪɟɝɭɥɢɪɨɜɤɢ ɬɟɦɩɟɪɚɬɭɪɵ o 1-ɨɣ ɫɬɭɩɟɧɢ 5 = Ɋɭɱɤɚ ɞɥɹ ɪɟɝɭɥɢɪɨɜɤɢ ɬɟɦɩɟɪɚɬɭɪɵ 2-ɨɣ ɫɬɭɩɟɧɢ 2.3 ȼɤɥɸɱɟɧɢɟ ɢ ɜɵɤɥɸɱɟɧɢɟ ȼɤɥɸɱɟɧɢɟ ɤɨɬɥɚ Ɉɬɤɪɨɣɬɟ ɨɬɫɟɱɧɵɟ ɤɥɚɩɚɧɵ ɬɨɩɥɢɜɚ. ȼɤɥɸɱɢɬɟ ɷɥɟɤɬɪɨɩɢɬɚɧɢɟ ɚɩɩɚɪɚɬɚ. ɇɚɠɦɢɬɟ ɤɧɨɩɤɭ 2 ɪɢɫ. 1, ɱɬɨɛɵ ɩɨɞɚɬɶ ɜ ɤɨɬɟɥ ɢ ɝɨɪɟɥɤɭ ɧɚɩɪɹɠɟɧɢɟ. Ɉɩɢɫɚɧɢɟ ɩɪɢɧɰɢɩɚ ɪɚɛɨɬɵ ɝɨɪɟɥɤɢ ɢ ɭɤɚɡɚɧɢɹ ɩɨ ɟɟ ɷɤɫɩɥɭɚɬɚɰɢɢ ɫɦɨɬɪɟɬɶ ɜ ɫɨɨɬɜɟɬɫɬɜɭɸɳɟɦ ɪɭɤɨɜɨɞɫɬɜɟ. ȼɵɤɥɸɱɟɧɢɟ ɤɨɬɥɚ Ⱦɥɹ ɜɵɤɥɸɱɟɧɢɹ ɤɨɬɥɚ ɧɚ ɤɪɚɬɤɨɜɪɟɦɟɧɧɵɣ ɩɟɪɢɨɞ ɞɨɫɬɚɬɨɱɧɨ ɧɚɠɚɬɶ ɤɧɨɩɤɭ 2 ɪɢɫ. 1 ɧɚ ɩɭɥɶɬɟ ɭɩɪɚɜɥɟɧɢɹ ɢ ɩɟɪɟɜɟɫɬɢ ɟɟ ɜ ɩɨɥɨɠɟɧɢɟ “0”. Ⱦɥɹ ɜɵɤɥɸɱɟɧɢɹ ɤɨɬɥɚ ɧɚ ɞɥɢɬɟɥɶɧɵɣ ɩɟɪɢɨɞ, ɩɨɦɢɦɨ ɧɚɠɚɬɢɹ ɢ ɩɨɜɨɪɨɬɚ ɤɧɨɩɤɢ 2 ɜ ɧɭɥɟɜɨɟ ɩɨɥɨɠɟɧɢɟ, ɨɛɹɡɚɬɟɥɶɧɨ ɡɚɤɪɵɬɶ ɨɬɫɟɱɧɵɣ ɤɥɚɩɚɧ ɬɨɩɥɢɜɚ. ȼɨ ɜɪɟɦɹ ɞɥɢɬɟɥɶɧɨɝɨ ɧɟɢɫɩɨɥɶɡɨɜɚɧɢɹ ɤɨɬɥɚ ɜ ɡɢɦɧɢɣ ɩɟɪɢɨɞ ɜɨ ɢɡɛɟɠɚɧɢɟ ɭɳɟɪɛɚ ɨɬ ɜɨɡɦɨɠɧɨɝɨ ɡɚɦɟɪɡɚɧɢɹ ɧɟɨɛɯɨɞɢɦɨ ɞɨɛɚɜɢɬɶ ɫɨɨɬɜɟɬɫɬɜɭɸɳɢɣ ɚɧɬɢɮɪɢɡ ɜ ɫɢɫɬɟɦɭ ɨɬɨɩɥɟɧɢɹ ɢɥɢ ɩɨɥɧɨɫɬɶɸ ɫɥɢɬɶ ɜɨɞɭ ɢɡ ɫɢɫɬɟɦɵ. 2.4 Ɋɟɝɭɥɢɪɨɜɤɢ Ɋɟɝɭɥɢɪɨɜɤɚ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɞɵ ɜ ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ ɍɫɬɚɧɨɜɢɬɟ ɠɟɥɚɟɦɭɸ ɬɟɦɩɟɪɚɬɭɪɭ ɫɢɫɬɟɦɵ ɫ ɩɨɦɨɳɶɸ ɤɧɨɩɤɢ ɬɟɪɦɨɫɬɚɬɚ 4 ɧɚ ɪɢɫ. 1. Ⱦɥɹ ɦɨɞɟɥɢ ATLAS 95 ɪɟɝɭɥɢɪɭɣɬɟ ɬɟɦɩɟɪɚɬɭɪɭ 2-ɨɣ ɫɬɭɩɟɧɢ ɫ ɩɨɦɨɳɶɸ ɤɧɨɩɤɢ ɬɟɪɦɨɫɬɚɬɚ 5 ɧɚ 10°C ɧɢɠɟ ɬɟɦɩɟɪɚɬɭɪɵ 1-ɨɣ ɫɬɭɩɟɧɢ. A ȼȺɀɇɈȿ ɉɊɂɆȿɑȺɇɂȿ: ɬɟɦɩɟɪɚɬɭɪɚ 2-ɨɣ ɫɬɭɩɟɧɢ ɞɨɥɠɧɚ ɛɵɬɶ ɜɫɟɝɞɚ ɧɢɠɟ ɬɟɦɩɟɪɚɬɭɪɵ 1-ɨɣ ɫɬɭɩɟɧɢ.. ɪɢɫ. 3 - Ɋɟɝɭɥɢɪɨɜɚɧɢɟ ɬɟɦɩɟɪɚɬɭɪɵ ɦɨɞɟɥɢ ATLAS 95 Ɋɟɝɭɥɢɪɨɜɤɚ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɡɞɭɯɚ ɜ ɩɨɦɟɳɟɧɢɢ (ɫ ɩɨɦɨɳɶɸ ɨɩɰɢɨɧɧɨɝɨ ɬɟɪɦɨɫɬɚɬɚ ɬɟɦɩɟɪɚɬɭɪɵ ɜ ɩɨɦɟɳɟɧɢɢ). Ɂɚɞɚɣɬɟ ɫ ɩɨɦɨɳɶɸ ɬɟɪɦɨɫɬɚɬɚ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɡɞɭɯɚ ɜ ɩɨɦɟɳɟɧɢɢ ɧɭɠɧɭɸ ɬɟɦɩɟɪɚɬɭɪɭ ɜɧɭɬɪɢ ɩɨɦɟɳɟɧɢɹ. ɉɪɢ ɨɬɫɭɬɫɬɜɢɢ ɬɟɪɦɨɫɬɚɬɚ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɡɞɭɯɚ ɜ ɩɨɦɟɳɟɧɢɹ ɤɨɬɟɥ ɨɛɟɫɩɟɱɢɜɚɟɬ ɩɨɞɞɟɪɠɚɧɢɟ ɜ ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ ɡɚɞɚɧɧɨɣ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɞɵ. 3. ɆɈɇɌȺɀ 3.1 ɍɤɚɡɚɧɢɹ ɨɛɳɟɝɨ ɯɚɪɚɤɬɟɪɚ ɍɋɌȺɇɈȼɄȺ ɂ ɇȺɋɌɊɈɃɄȺ ȽɈɊȿɅɄɂ ȾɈɅɀɇȺ ɈɋɍɓȿɋɌȼɅəɌɖɋə ɌɈɅɖɄɈ ɋɉȿɐɂȺɅɂɁɂɊɈȼȺɇɇɕɆ ɉȿɊɋɈɇȺɅɈɆ, ɂɆȿɘɓɂɆ ɉɊɈȼȿɊȿɇɇɍɘ ɄȼȺɅɂɎɂɄȺɐɂɘ, ɉɊɂ ɋɈȻɅɘȾȿɇɂɂ ɉɊɂȼȿȾȿɇɇɕɏ ȼ ɇȺɋɌɈəɓȿɆ ɌȿɏɇɂɑȿɋɄɈɆ ɊɍɄɈȼɈȾɋɌȼȿ ɍɄȺɁȺɇɂɃ, ɉɊȿȾɉɂɋȺɇɂɃ ȾȿɃɋɌȼɍɘɓȿȽɈ ɁȺɄɈɇɈȾȺɌȿɅɖɋɌȼȺ, ɉɈɅɈɀȿɇɂɃ ɆȿɋɌɇɕɏ ɇɈɊɆ ɂ ɉɊȺȼɂɅ, ɂ ȼ ɋɈɈɌȼȿɌɋɌȼɂɂ ɋ ɉɊɂɇəɌɕɆɂ ɌȿɏɇɂɑȿɋɄɂɆɂ ɌɊȿȻɈȼȺɇɂəɆɂ. 3.2 Ɇɟɫɬɨ ɭɫɬɚɧɨɜɤɢ Ʉɨɬɟɥ ɞɨɥɠɟɧ ɛɵɬɶ ɭɫɬɚɧɨɜɥɟɧ ɜ ɫɩɟɰɢɚɥɶɧɨ ɨɬɜɟɞɟɧɧɨɦ ɞɥɹ ɷɬɨɣ ɰɟɥɢ ɩɨɦɟɳɟɧɢɢ, ɢɦɟɸɳɟɦ ɨɬɜɟɪɫɬɢɹ, ɨɛɟɫɩɟɱɢɜɚɸɳɢɟ ɞɨɫɬɚɬɨɱɧɭɸ ɜɟɧɬɢɥɹɰɢɸ ɜ ɫɨɨɬɜɟɬɫɬɜɢɢ ɫ ɞɟɣɫɬɜɭɸɳɢɦɢ ɧɨɪɦɚɦɢ. ȿɫɥɢ ɜ ɨɞɧɨɦ ɩɨɦɟɳɟɧɢɢ ɭɫɬɚɧɨɜɥɟɧɵ ɧɟɤɨɬɨɪɵɟ ɝɨɪɟɥɤɢ ɢɥɢ ɜɵɬɹɠɧɵɟ ɜɟɧɬɢɥɹɬɨɪɵ, ɤɨɬɨɪɵɟ ɦɨɝɭɬ ɨɞɧɨɜɪɟɦɟɧɧɨ ɧɚɯɨɞɢɬɶɫɹ ɜ ɪɚɛɨɬɟ, ɬɨ ɪɚɡɦɟɪ ɜɟɧɬɢɥɹɰɢɨɧɧɵɯ ɨɬɜɟɪɫɬɢɣ ɞɨɥɠɟɧ ɛɵɬɶ ɞɨɫɬɚɬɨɱɧɵɦɢ ɞɥɹ ɨɞɧɨɜɪɟɦɟɧɧɨɣ ɪɚɛɨɬɵ ɜɫɟɯ ɚɩɩɚɪɚɬɨɜ. ȼ ɦɟɫɬɟ ɭɫɬɚɧɨɜɤɢ ɤɨɬɥɚ ɧɟ ɞɨɥɠɧɵ ɧɚɯɨɞɢɬɶɫɹ ɨɝɧɟɨɩɚɫɧɵɟ ɩɪɟɞɦɟɬɵ ɢɥɢ ɦɚɬɟɪɢɚɥɵ, ɟɞɤɢɟ ɝɚɡɵ, ɩɵɥɶ ɢ ɞɪɭɝɢɟ ɥɟɬɭɱɢɟ ɜɟɳɟɫɬɜɚ, ɡɚɫɚɫɵɜɚɧɢɟ ɤɨɬɨɪɵɯ ɜɟɧɬɢɥɹɬɨɪɨɦ ɦɨɠɟɬ ɩɪɢɜɟɫɬɢ ɤ ɡɚɝɪɹɡɧɟɧɢɸ ɜɧɭɬɪɟɧɧɢɯ ɤɚɧɚɥɨɜ ɝɨɪɟɥɤɢ ɢɥɢ ɝɨɪɟɥɨɱɧɨɣ ɝɨɥɨɜɤɢ. ɉɨɦɟɳɟɧɢɟ ɞɨɥɠɧɨ ɛɵɬɶ ɫɭɯɢɦ ɢ ɧɟ ɩɨɞɜɟɪɝɚɬɶɫɹ ɜɨɡɞɟɣɫɬɜɢɸ ɞɨɠɞɹ, ɫɧɟɝɚ ɢɥɢ ɦɨɪɨɡɚ. A ȿɫɥɢ ɚɝɪɟɝɚɬ ɭɫɬɚɧɚɜɥɢɜɚɟɬɫɹ ɫɪɟɞɢ ɦɟɛɟɥɢ ɢɥɢ ɛɨɤɨɦ ɤ ɫɬɟɧɟ, ɫɥɟɞɭɟɬ ɩɪɟɞɭɫɦɨɬɪɟɬɶ ɫɜɨɛɨɞɧɨɟ ɩɪɨɫɬɪɚɧɫɬɜɨ, ɧɟɨɛɯɨɞɢɦɨɟ ɞɥɹ ɞɟɦɨɧɬɚɠɚ ɤɨɠɭɯɚ ɢ ɩɪɨɜɟɞɟɧɢɹ ɨɛɵɱɧɵɯ ɪɚɛɨɬ ɩɨ ɬɟɯɨɛɫɥɭɠɢɜɚɧɢɸ. ȼ ɱɚɫɬɧɨɫɬɢ ɭɛɟɞɢɬɶɫɹ, ɱɬɨ ɩɨɫɥɟ ɦɨɧɬɚɠɚ ɤɨɬɥɚ ɫ ɝɨɪɟɥɤɨɣ ɧɚ ɩɟɪɟɞɧɟɣ ɞɜɟɪɰɟ, ɨɬɤɪɵɜɚɧɢɟ ɩɨɫɥɟɞɧɟɣ ɧɟ ɜɵɡɵɜɚɥɨ ɜɪɟɡɚɧɢɟ ɝɨɪɟɥɤɢ ɜ ɫɬɟɧɭ ɢɥɢ ɜ ɫɨɫɟɞɧɟɟ ɨɛɨɪɭɞɨɜɚɧɢɟ 3.3 Ƚɢɞɪɚɜɥɢɱɟɫɤɢɟ ɫɨɟɞɢɧɟɧɢɹ Ɋɚɫɱɟɬ ɬɪɟɛɭɟɦɨɣ ɬɟɩɥɨɜɨɣ ɦɨɳɧɨɫɬɢ ɤɨɬɥɚ ɩɪɨɢɡɜɨɞɢɬɫɹ ɩɪɟɞɜɚɪɢɬɟɥɶɧɨ, ɢɫɯɨɞɹ ɢɡ ɩɨɬɪɟɛɧɨɫɬɢ ɡɞɚɧɢɹ ɜ ɬɟɩɥɟ, ɪɚɫɫɱɢɬɵɜɚɟɦɨɣ ɩɨ ɞɟɣɫɬɜɭɸɳɢɦ ɧɨɪɦɚɦ. Ⱦɥɹ ɨɛɟɫɩɟɱɟɧɢɹ ɩɪɚɜɢɥɶɧɨɝɨ ɢ ɧɚɞɟɠɧɨɝɨ ɮɭɧɤɰɢɨɧɢɪɨɜɚɧɢɹ ɫɢɫɬɟɦɚ ɞɨɥɠɧɚ ɛɵɬɶ ɨɫɧɚɳɟɧɚ ɜɫɟɦɢ ɧɟɨɛɯɨɞɢɦɵɦɢ ɷɥɟɦɟɧɬɚɦɢ. Ɋɟɤɨɦɟɧɞɭɟɬɫɹ ɭɫɬɚɧɨɜɢɬɶ ɦɟɠɞɭ ɤɨɬɥɨɦ ɢ ɫɢɫɬɟɦɨɣ ɨɬɨɩɥɟɧɢɹ ɨɬɫɟɱɧɵɟ ɤɥɚɩɚɧɵ, ɤɨɬɨɪɵɟ ɩɨɡɜɨɥɢɥɢ ɛɵ ɜ ɫɥɭɱɚɟ ɧɟɨɛɯɨɞɢɦɨɫɬɢ ɢɡɨɥɢɪɨɜɚɬɶ ɤɨɬɟɥ ɨɬ ɫɢɫɬɟɦɵ. B ɋɥɢɜɧɨɟ ɨɬɜɟɪɫɬɢɟ ɩɪɟɞɨɯɪɚɧɢɬɟɥɶɧɨɝɨ ɤɥɚɩɚɧɚ ɞɨɥɠɧɨ ɛɵɬɶ ɫɨɟɞɢɧɟɧɨ ɫ ɜɨɪɨɧɤɨɣ ɢɥɢ ɫ ɤɚɧɚɥɢɡɚɰɢɟɣ ɜɨ ɢɡɛɟɠɚɧɢɟ ɩɨɩɚɞɚɧɢɹ ɜɨɞɵ ɧɚ ɩɨɥ ɜ ɫɥɭɱɚɟ ɫɪɚɛɚɬɵɜɚɧɢɢ ɤɥɚɩɚɧɚ ɩɪɢ ɩɪɟɜɵɲɟɧɢɢ ɞɚɜɥɟɧɢɹ ɜ ɨɬɨɩɢɬɟɥɶɧɨɣ ɫɢɫɬɟɦɟ. ȼ ɩɪɨɬɢɜɧɨɦ ɫɥɭɱɚɟ ɢɡɝɨɬɨɜɢɬɟɥɶ ɤɨɬɥɚ ɧɟ ɧɟɫɟɬ ɧɢɤɚɤɨɣ ɨɬɜɟɬɫɬɜɟɧɧɨɫɬɢ ɡɚ ɡɚɬɨɩɥɟɧɢɟ ɩɨɦɟɳɟɧɢɹ ɩɪɢ ɫɪɚɛɚɬɵɜɚɧɢɢ ɩɪɟɞɨɯɪɚɧɢɬɟɥɶɧɨɝɨ ɤɥɚɩɚɧɚ. ɇɟ ɢɫɩɨɥɶɡɭɣɬɟ ɬɪɭɛɵ ɫɢɫɬɟɦɵ ɜɨɞɨɫɧɚɛɠɟɧɢɹ ɞɥɹ ɡɚɡɟɦɥɟɧɢɹ ɷɥɟɤɬɪɢɱɟɫɤɢɯ ɚɩɩɚɪɚɬɨɜ. ɉɟɪɟɞ ɦɨɧɬɚɠɨɦ ɬɳɚɬɟɥɶɧɨ ɩɪɨɦɨɣɬɟ ɜɫɟ ɬɪɭɛɵ ɫɢɫɬɟɦɵ ɞɥɹ ɭɞɚɥɟɧɢɹ ɨɫɬɚɬɨɱɧɵɯ ɡɚɝɪɹɡɧɟɧɹɸɳɢɯ ɜɟɳɟɫɬɜ ɢɥɢ ɩɨɫɬɨɪɨɧɧɢɯ ɜɤɥɸɱɟɧɢɣ, ɦɨɝɭɳɢɯ ɩɨɦɟɲɚɬɶ ɩɪɚɜɢɥɶɧɨɣ ɪɚɛɨɬɟ ɚɝɪɟɝɚɬɚ. ȼɵɩɨɥɧɢɬɟ ɩɨɞɤɥɸɱɟɧɢɟ ɬɪɭɛ ɤ ɫɨɨɬɜɟɬɫɬɜɭɸɳɢɦ ɲɬɭɰɟɪɚɦ, ɤɚɤ ɩɨɤɚɡɚɧɨ ɧɚ ɪɢɫɭɧɤɟ ɧɚ ɢcap. 5 ɢ ɫɨɝɥɚɫɧɨ ɫɢɦɜɨɥɚɦ, ɢɦɟɸɳɢɦɫɹ ɧɚ ɫɚɦɨɦ ɚɩɩɚɪɚɬɟ. A Ⱥɩɩɚɪɚɬ ɩɨɫɬɚɜɥɹɟɬɫɹ ɛɟɡ ɪɚɫɲɢɪɢɬɟɥɶɧɨɝɨ ɛɚɤɚ ɭɫɬɚɧɨɜɤɚ ɢ ɩɪɢɫɨɟɞɢɧɟɧɢɟ ɤɨɬɨɪɨɝɨ ɞɨɥɠɧɵ ɨɫɭɳɟɫɬɜɥɹɬɶɫɹ ɦɨɧɬɚɠɧɢɤɨɦ ɇɚɩɨɦɢɧɚɟɦ, ɱɬɨ ɞɚɜɥɟɧɢɟ ɜ ɯɨɥɨɞɧɨɣ ɫɢɫɬɟɦɟ ɞɨɥɠɧɨ ɫɨɫɬɚɜɥɹɬɶ 1 ɛɚɪ ɏɚɪɚɤɬɟɪɢɫɬɢɤɢ ɜɨɞɵ ɞɥɹ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ ȼ ɫɥɭɱɚɟ, ɟɫɥɢ ɠɟɫɬɤɨɫɬɶ ɜɨɞɵ ɩɪɟɜɵɲɚɟɬ 25° Fr (1°F = 10 ɩɩɦ CaCO3), ɢɫɩɨɥɶɡɭɟɦɚɹ ɜɨɞɚ ɞɨɥɠɧɚ ɛɵɬɶ ɧɚɞɥɟɠɚɳɢɦ ɨɛɪɚɡɨɦ ɩɨɞɝɨɬɨɜɥɟɧɚ, ɱɬɨɛɵ ɩɪɟɞɨɬɜɪɚɳɚɬɶ ɨɛɪɚɡɨɜɚɧɢɟ ɧɚɤɢɩɢ ɧɚ ɤɨɬɥɟ. ɉɨɫɥɟ ɩɨɞɝɨɬɨɜɤɢ ɠɟɫɬɤɨɫɬɶ ɜɨɞɵ ɧɟ ɞɨɥɠɧɚ ɛɵɬɶ ɧɢɠɟ 15°F (Ⱦɉ 236/88 ɨ ɩɨɞɝɨɬɨɜɤɟ ɜɨɞɵ, ɩɪɟɞɧɚɡɧɚɱɟɧɧɨɣ ɞɥɹ ɱɟɥɨɜɟɱɟɫɤɨɝɨ ɩɨɬɪɟɛɥɟɧɢɹ). ȼɨɞɨɩɨɞɝɨɬɨɜɤɚ ɨɛɹɡɚɬɟɥɶɧɚɹ, ɟɫɥɢ ɫɢɫɬɟɦɚ ɢɦɟɟɬ ɛɨɥɶɲɭɸ ɩɪɨɬɹɠɟɧɧɨɫɬɶ ɢɥɢ ɩɪɢ ɱɚɫɬɨɦ ɜɵɩɨɥɧɟɧɢɢ ɩɨɞɩɢɬɤɢ ɫɢɫɬɟɦɵ. B ȿɫɥɢ ɜ ɬɨɱɤɟ ɩɨɞɜɨɞɚ ɯɨɥɨɞɧɨɣ ɜɨɞɵ ɭɫɬɚɧɚɜɥɢɜɚɟɬɫɹ ɭɫɬɪɨɣɫɬɜɨ ɭɦɹɝɱɟɧɢɹ, ɨɛɪɚɬɢɬɢɟ ɜɧɢɦɚɧɢɟ ɧɚ ɬɨ, ɱɬɨɛɵ ɧɟ ɫɥɢɲɤɨɦ ɦɧɨɝɨ ɫɧɢɡɢɬɶ ɠɟɫɬɤɨɫɬɶ ɜɨɞɵ. ɇɚ ɫɚɦɨɦ ɞɟɥɟ ɷɬɨ ɦɨɠɟɬ ɩɪɢɜɟɫɬɢ ɤ ɩɪɟɠɞɟɜɪɟɦɟɧɧɨɦɭ ɭɯɭɞɲɟɧɢɸ ɫɜɨɣɫɬɜ ɦɚɝɧɢɟɜɨɝɨ ɚɧɨɞɚ ɛɨɣɥɟɪɚ.                                        

Страница 10 PDF

Страница 11

ATLAS 34 RU cod. 3540S123 - 07/2010 (Rev. 00) ɋɢɫɬɟɦɚ ɡɚɳɢɬɵ ɨɬ ɡɚɦɟɪɡɚɧɢɹ, ɠɢɞɤɢɟ ɚɧɬɢɮɪɢɡɵ, ɞɨɛɚɜɤɢ ɢ ɢɧɝɢɛɢɬɨɪɵ ɂɫɩɨɥɶɡɨɜɚɧɢɟ ɠɢɞɤɢɯ ɚɧɬɢɮɪɢɡɨɜ, ɞɨɛɚɜɨɤ ɢ ɢɧɝɢɛɢɬɨɪɨɜ, ɪɚɡɪɟɲɚɟɬɫɹ ɜ ɫɥɭɱɚɟ ɧɟɨɛɯɨɞɢɦɨɫɬɢ ɬɨɥɶɤɨ ɢ ɢɫɤɥɸɱɢɬɟɥɶɧɨ, ɟɫɥɢ ɢɯ ɢɡɝɨɬɨɜɢɬɟɥɶ ɞɚɟɬ ɝɚɪɚɧɬɢɸ, ɩɨɞɬɜɟɪɠɞɚɸɳɭɸ, ɱɬɨ ɟɝɨ ɩɪɨɞɭɤɰɢɹ ɨɬɜɟɱɚɟɬ ɞɚɧɧɨɦɭ ɜɢɞɭ ɢɫɩɨɥɶɡɨɜɚɧɢɹ ɢ ɧɟ ɩɪɢɱɢɧɢɬ ɜɪɟɞɚ ɬɟɩɥɨɨɛɦɟɧɧɢɤɭ ɤɨɬɥɚ ɢ ɞɪɭɝɢɦ ɤɨɦɩɥɟɤɬɭɸɳɢɦ ɢ/ɢɥɢ ɦɚɬɟɪɢɚɥɚɦ, ɢɫɩɨɥɶɡɨɜɚɧɧɵɦ ɜ ɤɨɧɫɬɪɭɤɰɢɢ ɤɨɬɥɚ ɢ ɫɢɫɬɟɦɵ. Ɂɚɩɪɟɳɚɟɬɫɹ ɢɫɩɨɥɶɡɨɜɚɬɶ ɠɢɞɤɨɫɬɢ-ɚɧɬɢɮɪɢɡɵ, ɞɨɛɚɜɤɢ ɢ ɢɧɝɢɛɢɬɨɪɵ, ɧɟ ɩɪɟɞɧɚɡɧɚɱɟɧɧɵɟ ɫɩɟɰɢɚɥɶɧɨ ɞɥɹ ɩɪɢɦɟɧɟɧɢɹ ɜ ɬɟɩɥɨɜɵɯ ɭɫɬɚɧɨɜɤɚɯ ɢ ɧɟɫɨɜɦɟɫɬɢɦɵɟ ɫ ɦɚɬɟɪɢɚɥɚɦɢ, ɢɫɩɨɥɶɡɨɜɚɧɧɵɦɢ ɜ ɤɨɧɫɬɪɭɤɰɢɢ ɤɨɬɥɚ ɢ ɫɢɫɬɟɦɵ. 3.4 ɉɨɞɤɥɸɱɟɧɢɟ ɝɨɪɟɥɤɢ ɀɢɞɤɨɬɨɩɥɢɜɧɨɟ ɢɥɢ ɝɚɡɨɜɨɟ ɝɨɪɟɥɨɱɧɨɟ ɭɫɬɪɨɣɫɬɜɨ ɫ ɩɨɞɞɭɜɨɦ ɞɥɹ ɝɟɪɦɟɬɢɱɧɵɯ ɬɨɩɨɤ ɦɨɠɟɬ ɛɵɬɶ ɢɫɩɨɥɶɡɨɜɚɧɨ, ɟɫɥɢ ɟɝɨ ɪɚɛɨɱɢɟ ɯɚɪɚɤɬɟɪɢɫɬɢɤɢ ɫɨɨɬɜɟɬɫɬɜɭɸɬ ɪɚɡɦɟɪɚɦ ɬɨɩɤɢ ɤɨɬɥɚ ɢ ɫɨɡɞɚɜɚɟɦɨɦɭ ɜ ɧɟɣ ɢɡɛɵɬɨɱɧɨɦɭ ɞɚɜɥɟɧɢɸ. ȼɵɛɨɪ ɝɨɪɟɥɤɢ ɫɥɟɞɭɟɬ ɨɫɭɳɟɫɬɜɥɹɬɶ ɧɚ ɨɫɧɨɜɚɧɢɢ ɭɤɚɡɚɧɢɣ ɢɡɝɨɬɨɜɢɬɟɥɹ, ɫ ɭɱɟɬɨɦ ɪɚɛɨɱɢɯ ɩɚɪɚɦɟɬɪɨɜ, ɪɚɫɯɨɞɚ ɬɨɩɥɢɜɚ ɢ ɞɥɢɧɵ ɤɚɦɟɪɵ ɫɝɨɪɚɧɢɹ ɤɨɬɥɚ. Ɇɨɧɬɚɠ ɝɨɪɟɥɤɢ ɞɨɥɠɟɧ ɨɫɭɳɟɫɬɜɥɹɬɶɫɹ ɫɨɝɥɚɫɧɨ ɢɧɫɬɪɭɤɰɢɹɦ ɢɡɝɨɬɨɜɢɬɟɥɹ. 3.5 ɗɥɟɤɬɪɢɱɟɫɤɢɟ ɫɨɟɞɢɧɟɧɢɹ ɉɨɞɤɥɸɱɟɧɢɟ ɤ ɫɟɬɢ ɷɥɟɤɬɪɨɩɢɬɚɧɢɹ B ɗɥɟɤɬɪɢɱɟɫɤɚɹ ɛɟɡɨɩɚɫɧɨɫɬɶ ɚɩɩɚɪɚɬɚ ɨɛɟɫɩɟɱɢɜɚɟɬɫɹ ɬɨɥɶɤɨ ɩɪɢ ɟɝɨ ɩɪɚɜɢɥɶɧɨɦ ɩɨɞɤɥɸɱɟɧɢɢ ɤ ɤɨɧɬɭɪɭ ɡɚɡɟɦɥɟɧɢɹ, ɨɬɜɟɱɚɸɳɟɦɭ ɬɪɟɛɨɜɚɧɢɹɦ ɞɟɣɫɬɜɭɸɳɢɯ ɧɨɪɦ ɬɟɯɧɢɤɢ ɛɟɡɨɩɚɫɧɨɫɬɢ. ɗɮɮɟɤɬɢɜɧɨɫɬɶ ɤɨɧɬɭɪɚ ɡɚɡɟɦɥɟɧɢɹ ɢ ɟɝɨ ɫɨɨɬɜɟɬɫɬɜɢɟ ɧɨɪɦɚɦ ɞɨɥɠɧɵ ɛɵɬɶ ɩɪɨɜɟɪɟɧɵ ɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɦ ɩɟɪɫɨɧɚɥɨɦ. ɂɡɝɨɬɨɜɢɬɟɥɶ ɧɟ ɧɟɫɟɬ ɧɢɤɚɤɨɣ ɨɬɜɟɬɫɬɜɟɧɧɨɫɬɢ ɡɚ ɭɳɟɪɛ, ɦɨɝɭɳɢɣ ɛɵɬɶ ɩɪɢɱɢɧɟɧɧɵɦ ɨɬɫɭɬɫɬɜɢɟɦ ɡɚɡɟɦɥɟɧɢɹ ɚɝɪɟɝɚɬɚ. ɍɞɨɫɬɨɜɟɪɶɬɟɫɶ ɬɚɤɠɟ, ɱɬɨ ɫɢɫɬɟɦɚ ɷɥɟɤɬɪɨɩɢɬɚɧɢɹ ɫɨɨɬɜɟɬɫɬɜɭɟɬ ɦɚɤɫɢɦɚɥɶɧɨɣ ɩɨɬɪɟɛɥɹɟɦɨɣ ɦɨɳɧɨɫɬɢ ɚɝɪɟɝɚɬɚ, ɭɤɚɡɚɧɧɨɣ ɧɚ ɬɚɛɥɢɱɤɟ ɧɨɦɢɧɚɥɶɧɵɯ ɞɚɧɧɵɯ. ȼɧɭɬɪɟɧɧɢɟ ɷɥɟɤɬɪɢɱɟɫɤɢɟ ɫɨɟɞɢɧɟɧɢɹ ɜ ɤɨɬɥɟ ɭɠɟ ɜɵɩɨɥɧɟɧɵ, ɨɧ ɫɧɚɛɠɟɧ ɬɚɤɠɟ ɫɟɬɟɜɵɦ ɲɧɭɪɨɦ ɬɢɩɚ "Y" ɛɟɡ ɜɢɥɤɢ. ɉɨɞɤɥɸɱɟɧɢɟ ɤ ɫɟɬɢ ɞɨɥɠɧɨ ɛɵɬɶ ɩɨɫɬɨɹɧɧɵɦ, ɩɪɢɱɟɦ ɦɟɠɞɭ ɦɟɫɬɨɦ ɩɨɞɤɥɸɱɟɧɢɹ ɤ ɫɟɬɢ ɢ ɤɨɬɥɨɦ ɫɥɟɞɭɟɬ ɭɫɬɚɧɨɜɢɬɶ ɞɜɭɯɩɨɥɸɫɧɵɣ ɪɚɡɦɵɤɚɬɟɥɶ ɫ ɪɚɫɫɬɨɹɧɢɟɦ ɦɟɠɞɭ ɪɚɡɨɦɤɧɭɬɵɦɢ ɤɨɧɬɚɤɬɚɦɢ ɧɟ ɦɟɧɟɟ 3 ɦɦ, ɚ ɬɚɤɠɟ ɩɪɟɞɨɯɪɚɧɢɬɟɥɢ ɦɚɤɫ. ɧɨɦɢɧɚɥɨɦ 3A. ɉɪɢ ɩɨɞɤɥɸɱɟɧɢɢ ɤ ɫɟɬɢ ɜɚɠɧɨɟ ɡɧɚɱɟɧɢɟ ɢɦɟɟɬ ɫɨɛɥɸɞɟɧɢɟ ɩɨɥɹɪɧɨɫɬɢ (ɮɚɡɚ: ɤɨɪɢɱɧɟɜɵɣ ɩɪɨɜɨɞ / ɧɟɣɬɪɚɥɶ: ɫɢɧɢɣ ɩɪɨɜɨɞ / ɡɟɦɥɹ: ɠɟɥɬɨ-ɡɟɥɟɧɵɣ ɩɪɨɜɨɞ). ɉɪɢ ɦɨɧɬɚɠɟ ɢɥɢ ɡɚɦɟɧɟ ɫɟɬɟɜɨɝɨ ɲɧɭɪɚ ɡɟɦɥɹɧɨɣ ɩɪɨɜɨɞ ɞɨɥɠɟɧ ɛɵɬɶ ɜɵɩɨɥɧɟɧ ɧɚ 2 ɫɦ ɞɥɢɧɧɟɟ ɨɫɬɚɥɶɧɵɯ. B ɋɟɬɟɜɨɣ ɲɧɭɪ ɚɝɪɟɝɚɬɚ ɧɟ ɩɨɞɥɟɠɢɬ ɡɚɦɟɧɟ ɫɚɦɢɦ ɩɨɥɶɡɨɜɚɬɟɥɟɦ. ȼ ɫɥɭɱɚɟ ɩɨɜɪɟɠɞɟɧɢɹ ɫɟɬɟɜɨɝɨ ɲɧɭɪɚ ɜɵɤɥɸɱɢɬɟ ɚɝɪɟɝɚɬ; ɨɛɪɚɳɚɣɬɟɫɶ ɞɥɹ ɟɝɨ ɡɚɦɟɧɵ ɢɫɤɥɸɱɢɬɟɥɶɧɨ ɤ ɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɦ ɫɩɟɰɢɚɥɢɫɬɚɦ. ȼ ɫɥɭɱɚɟ ɡɚɦɟɧɵ ɫɟɬɟɜɨɝɨ ɲɧɭɪɚ ɢɫɩɨɥɶɡɭɣɬɟ ɢɫɤɥɸɱɢɬɟɥɶɧɨ ɤɚɛɟɥɶ ɬɢɩɚ “HAR H05 VV-F” 3x0,75 ɦɦ2 ɫ ɦɚɤɫɢɦɚɥɶɧɵɦ ɜɧɟɲɧɢɦ ɞɢɚɦɟɬɪɨɦ 8 ɦɦ. Ⱦɨɫɬɭɩ ɤ ɤɥɟɦɦɧɨɣ ɤɨɪɨɛɤɟ Ɉɬɜɢɧɢɬɢɬɟ ɨɛɚ ɜɢɧɬɚ “A” ɧɚ ɡɚɞɧɟɣ ɫɬɨɪɨɧɟ ɩɭɥɶɬɚ ɭɩɪɚɜɥɟɧɢɹ ɢ ɫɧɢɦɢɬɟ ɤɪɵɲɤɭ “B“. ɪɢɫ. 4 - Ⱦɨɫɬɭɩ ɤ ɤɥɟɦɦɧɨɣ ɤɨɪɨɛɤɟ 3.6 ɉɨɞɤɥɸɱɟɧɢɟ ɤɨɬɥɚ ɤ ɞɵɦɨɨɬɜɨɞɭ Ⱥɩɩɚɪɚɬ ɞɨɥɠɟɧ ɛɵɬɶ ɩɨɞɤɥɸɱɟɧ ɤ ɞɵɦɨɨɬɜɨɞɭ, ɫɨɨɬɜɟɬɫɬɜɭɸɳɟɦɭ ɞɟɣɫɬɜɭɸɳɢɦ ɧɨɪɦɚɦ. Ⱦɵɦɨɜɚɹ ɬɪɭɛɚ, ɫɨɟɞɢɧɹɸɳɚɹ ɤɨɬɟɥ ɫ ɞɵɦɨɨɬɜɨɞɨɦ ɞɨɥɠɧɚ ɛɵɬɶ ɢɡɝɨɬɨɜɥɟɧɚ ɢɡ ɦɚɬɟɪɢɚɥɚ, ɭɫɬɨɣɱɢɜɨɝɨ ɤ ɬɟɦɩɟɪɚɬɭɪɟ ɢ ɤɨɪɪɨɡɢɢ. Ɇɟɫɬɚ ɫɨɟɞɢɧɟɧɢɹ ɬɪɭɛ ɞɨɥɠɧɵ ɛɵɬɶ ɧɚɞɥɟɠɚɳɢɦ ɨɛɪɚɡɨɦ ɭɩɥɨɬɧɟɧɵ, ɚ ɞɥɹ ɩɪɟɞɨɬɜɪɚɳɟɧɢɹ ɨɛɪɚɡɨɜɚɧɢɹ ɤɨɧɞɟɧɫɚɬɚ ɞɵɦɨɯɨɞ ɪɟɤɨɦɟɧɞɭɟɬɫɹ ɭɬɟɩɥɹɬɶ ɩɨ ɜɫɟɣ ɟɝɨ ɞɥɢɧɟ. 4. ɌȿɏɇɂɱȿɋɄɈȿ ɈȻɋɅɍɀɂȼȺɇɂȿ ȼɫɟ ɧɢɠɟɨɩɢɫɚɧɧɵɟ ɨɩɟɪɚɰɢɢ ɩɨ ɪɟɝɭɥɢɪɨɜɤɟ, ɩɟɪɟɨɛɨɪɭɞɨɜɚɧɢɸ, ɜɜɨɞɭ ɜ ɷɤɫɩɥɭɚɬɚɰɢɸ ɢ ɬɟɯɨɛɫɥɭɠɢɜɚɧɢɸ ɩɨɞɥɟɠɚɬ ɜɵɩɨɥɧɟɧɢɸ ɢɫɤɥɸɱɢɬɟɥɶɧɨ ɫɢɥɚɦɢ ɫɩɟɰɢɚɥɢɫɬɨɜ ɫ ɜɵɫɨɤɨɣ ɤɜɚɥɢɮɢɤɚɰɢɟɣ (ɭɞɨɜɥɟɬɜɨɪɹɸɳɢɦɢ ɩɪɨɮɟɫɫɢɨɧɚɥɶɧɵɦ ɬɟɯɧɢɱɟɫɤɢɦ ɬɪɟɛɨɜɚɧɢɹɦ, ɩɪɟɞɭɫɦɨɬɪɟɧɧɵɦ ɞɟɣɫɬɜɭɸɳɢɦ ɡɚɤɨɧɨɞɚɬɟɥɶɫɬɜɨɦ ), ɬɚɤɢɯ ɤɚɤ ɫɨɬɪɭɞɧɢɤɢ ɨɛɫɥɭɠɢɜɚɸɳɟɝɨ ɜɚɲɭ ɬɟɪɪɢɬɨɪɢɸ ɫɟɪɜɢɫɧɨɝɨ ɰɟɧɬɪɚ. FERROLI ɫɧɢɦɚɟɬ ɫ ɫɟɛɹ ɜɫɹɤɭɸ ɨɬɜɟɬɫɬɜɟɧɧɨɫɬɶ ɡɚ ɬɪɚɜɦɵ ɢɥɢ ɦɚɬɟɪɢɚɥɶɧɵɣ ɭɳɟɪɛ, ɤɨɬɨɪɵɟ ɦɨɝɭɬ ɛɵɬɶ ɩɪɢɱɢɧɟɧɵ ɜ ɪɟɡɭɥɶɬɚɬɟ ɧɟɫɚɧɤɰɢɨɧɢɪɨɜɚɧɧɨɝɨ ɢɡɦɟɧɟɧɢɹ ɤɨɧɫɬɪɭɤɰɢɢ ɚɝɪɟɝɚɬɚ ɧɟɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɦɢ ɢ ɧɟɭɩɨɥɧɨɦɨɱɟɧɧɵɦɢ ɥɢɰɚɦɢ. 4.1 Ɋɟɝɭɥɢɪɨɜɤɢ Ɋɟɝɭɥɢɪɨɜɚɧɢɟ ɝɨɪɟɥɤɢ ɉɪɚɜɢɥɶɧɨɫɬɶ ɪɚɛɨɬɵ ɢ ɤɨɷɮɮɢɰɢɟɧɬ ɩɨɥɟɡɧɨɝɨ ɞɟɣɫɬɜɢɹ ɤɨɬɥɚ ɡɚɜɢɫɹɬ ɝɥɚɜɧɵɦ ɨɛɪɚɡɨɦ ɨɬ ɬɨɱɧɨɫɬɢ ɪɟɝɭɥɢɪɨɜɤɢ ɝɨɪɟɥɤɢ. Ⱦɚɧɧɚɹ ɪɟɝɭɥɢɪɨɜɤɚ ɞɨɥɠɧɚ ɜɵɩɨɥɧɹɬɶɫɹ ɩɪɢ ɬɳɚɬɟɥɶɧɨɦ ɫɨɛɥɸɞɟɧɢɢ ɢɧɫɬɪɭɤɰɢɣ ɢɡɝɨɬɨɜɢɬɟɥɹ. ȼ ɞɜɭɯɫɬɭɩɟɧɱɚɬɵɯ ɝɨɪɟɥɤɚɯ ɦɨɳɧɨɫɬɶ ɩɟɪɜɨɣ ɫɬɭɩɟɧɢ ɫɥɟɞɭɟɬ ɪɟɝɭɥɢɪɨɜɚɬɶ ɬɚɤ, ɱɬɨɛɵ ɨɧɚ ɫɨɫɬɚɜɥɹɥɚ ɧɟ ɦɟɧɟɟ ɦɢɧɢɦɚɥɶɧɨɣ ɧɨɦɢɧɚɥɶɧɨɣ ɦɨɳɧɨɫɬɢ ɤɨɬɥɚ. Ɇɨɳɧɨɫɬɶ ɜɬɨɪɨɣ ɫɬɭɩɟɧɢ ɧɟ ɞɨɥɠɧɚ ɛɵɬɶ ɛɨɥɶɲɟ ɦɚɤɫɢɦɚɥɶɧɨɣ ɧɨɦɢɧɚɥɶɧɨɣ ɦɨɳɧɨɫɬɢ ɤɨɬɥɚ. 4.2 ȼɜɨɞ ɜ ɷɤɫɩɥɭɚɬɚɰɢɸ B Ʉɨɧɬɪɨɥɶɧɵɟ ɨɩɟɪɚɰɢɢ, ɤɨɬɨɪɵɟ ɫɥɟɞɭɟɬ ɜɵɩɨɥɧɹɬɶ ɩɟɪɟɞ ɩɟɪɜɵɦ ɪɨɡɠɢɝɨɦ, ɚ ɬɚɤɠɟ ɩɨɫɥɟ ɩɪɨɜɟɞɟɧɢɹ ɬɟɯɧɢɱɟɫɤɨɝɨ ɨɛɫɥɭɠɢɜɚɧɢɹ, ɜɨ ɜɪɟɦɹ ɤɨɬɨɪɨɝɨ ɤɨɬɟɥ ɛɵɥ ɨɬɫɨɟɞɢɧɟɧ ɨɬ ɫɟɬɟɣ ɩɢɬɚɧɢɹ ɢɥɢ ɛɵɥɢ ɩɪɨɢɡɜɟɞɟɧɵ ɪɚɛɨɬɵ ɧɚ ɩɪɟɞɨɯɪɚɧɢɬɟɥɶɧɵɯ ɭɫɬɪɨɣɫɬɜɚɯ ɢɥɢ ɞɟɬɚɥɹɯ ɤɨɬɥɚ: ɉɟɪɟɞ ɜɤɥɸɱɟɧɢɟɦ ɤɨɬɥɚ • Ɉɬɤɪɨɣɬɟ ɡɚɩɨɪɧɵɟ ɤɥɚɩɚɧɵ, ɪɚɫɩɨɥɨɠɟɧɧɵɟ ɦɟɠɞɭ ɤɨɬɥɨɦ ɢ ɝɚɡɨ- ɜɨɞɨɩɪɨɜɨɞɚɦɢ. • ɉɪɨɜɟɪɶɬɟ ɝɟɪɦɟɬɢɱɧɨɫɬɶ ɫɢɫɬɟɦɵ ɩɨɞɚɱɢ ɬɨɩɥɢɜɚ. • ɉɪɨɜɟɪɶɬɟ ɩɪɚɜɢɥɶɧɨɫɬɶ ɞɚɜɥɟɧɢɹ ɜ ɪɚɫɲɢɪɢɬɟɥɶɧɨɦ ɛɚɤɟ • Ɂɚɩɨɥɧɢɬɟ ɜɨɞɨɣ ɫɢɫɬɟɦɭ ɢ ɩɨɥɧɨɫɬɶɸ ɫɩɭɫɬɢɬɟ ɜɨɡɞɭɯ ɤɨɬɥɚ ɢ ɢɡ ɫɢɫɬɟɦɵ, ɨɬɤɪɵɜ ɜɨɡɞɭɯɨɜɵɩɭɫɤɧɨɣ ɜɟɧɬɢɥɶ ɧɚ ɤɨɬɥɟ ɢ (ɟɫɥɢ ɬɚɤɨɜɵɟ ɢɦɟɸɬɫɹ) ɜɨɡɞɭɯɨɜɵɩɭɫɤɧɵɟ ɜɟɧɬɢɥɢ, ɭɫɬɚɧɨɜɥɟɧɧɵɟ ɜ ɪɚɡɥɢɱɧɵɯ ɦɟɫɬɚɯ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ. • ɍɞɨɫɬɨɜɟɪɶɬɟɫɶ ɜ ɨɬɫɭɬɫɬɜɢɢ ɭɬɟɱɟɤ ɜɨɞɵ ɢɡ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ, ɤɨɧɬɭɪɚ Ƚȼɋ, ɢɡ ɤɨɬɥɚ ɢ ɜ ɪɚɡɥɢɱɧɵɯ ɫɨɟɞɢɧɟɧɢɹɯ. • ɉɪɨɜɟɪɶɬɟ ɩɪɚɜɢɥɶɧɨɫɬɶ ɜɵɩɨɥɧɟɧɢɹ ɷɥɟɤɬɪɢɱɟɫɤɢɯ ɫɨɟɞɢɧɟɧɢɣ ɢ ɷɮɮɟɤɬɢɜɧɨɫɬɶ ɡɚɡɟɦɥɟɧɢɹ • ɉɪɨɜɟɪɶɬɟ, ɱɬɨ ɜ ɧɟɩɨɫɪɟɞɫɬɜɟɧɧɨɣ ɛɥɢɡɨɫɬɢ ɨɬ ɤɨɬɥɚ ɧɟ ɧɚɯɨɞɹɬɫɹ ɨɝɧɟɨɩɚɫɧɵɧ ɠɢɞɤɨɫɬɢ ɢ ɦɚɬɟɪɢɚɥɵ. Ʉɨɧɬɪɨɥɶɧɵɟ ɨɩɟɪɚɰɢɢ ɜɨ ɜɪɟɦɹ ɪɚɛɨɬɵ • ȼɤɥɸɱɢɬɟ ɚɝɪɟɝɚɬ, ɤɚɤ ɨɩɢɫɚɧɨ ɜ sez. 2.3. • ɍɞɨɫɬɨɜɟɪɶɬɟɫɶ ɜ ɝɟɪɦɟɬɢɱɧɨɫɬɢ ɤɚɦɟɪɵ ɫɝɨɪɚɧɢɹ ɢ ɝɢɞɪɚɜɥɢɱɟɫɤɨɣ ɫɢɫɬɟɦɵ. • ɉɪɨɜɟɪɶɬɟ ɷɮɮɟɤɬɢɜɧɨɫɬɶ ɮɭɧɤɰɢɨɧɢɪɨɜɚɧɢɹ ɞɵɦɨɯɨɞɨɜ (ɞɥɹ ɩɪɢɬɨɤɚ ɜɨɡɞɭɯɚ ɢ ɭɞɚɥɟɧɢɹ ɩɪɨɞɭɤɬɨɜ ɫɝɨɪɚɧɢɹ) ɜɨ ɜɪɟɦɹ ɪɚɛɨɬɵ ɤɨɬɥɚ. • ɍɞɨɫɬɨɜɟɪɶɬɟɫɶ ɜ ɩɪɚɜɢɥɶɧɨɫɬɢ ɰɢɪɤɭɥɹɰɢɢ ɜɨɞɵ ɦɟɠɞɭ ɤɨɬɥɨɦ ɢ ɫɢɫɬɟɦɨɣ. • ɉɪɨɜɟɪɶɬɟ ɡɚɠɢɝɚɧɢɟ ɝɨɪɟɥɤɢ, ɨɫɭɳɟɫɬɜɢɜ ɪɚɡɥɢɱɧɵɟ ɢɫɩɵɬɚɧɢɹ ɩɨ ɜɤɥɸɱɟɧɢɸ ɢ ɜɵɤɥɸɱɟɧɢɸ ɤɨɬɥɚ ɫ ɩɨɦɨɳɶɸ ɬɟɪɦɨɫɬɚɬɚ ɬɟɦɩɟɪɚɬɭɪɵ ɜɨɡɞɭɯɚ ɜ ɩɨɦɟɳɟɧɢɢ ɢɥɢ ɭɫɬɪɨɣɫɬɜɚ ɞɢɫɬɚɧɰɢɨɧɧɨɝɨ ɭɩɪɚɜɥɟɧɢɹ. • ɍɞɨɫɬɨɜɟɪɶɬɟɫɶ ɩɨ ɩɨɤɚɡɚɧɢɹɦ ɫɱɟɬɱɢɤɚ, ɱɬɨ ɪɚɫɯɨɞ ɝɚɡɚ ɫɨɨɬɜɟɬɫɬɜɭɟɬ ɜɟɥɢɱɢɧɟ, ɭɤɚɡɚɧɧɨɣ ɜ ɬɚɛɥɢɰɟ ɬɟɯɧɢɱɟɫɤɢɯ ɞɚɧɧɵɯ ɜ sez. 5.3. • ɉɪɨɜɟɪɶɬɟ ɝɟɪɦɟɬɢɱɧɨɫɬɶ ɞɜɟɪɰɵ ɝɨɪɟɥɤɢ ɢ ɞɵɦɨɜɨɣ ɤɚɦɟɪɵ. • ɉɪɨɜɟɪɶɬɟ ɩɪɚɜɢɥɶɧɨɫɬɶ ɪɚɛɨɬɵ ɝɨɪɟɥɤɢ. ɇɚɫɬɨɹɳɢɣ ɤɨɧɬɪɨɥɶ ɨɫɭɳɟɫɬɜɥɹɟɬɫɹ ɫ ɩɨɦɨɳɶɸ ɩɪɟɞɭɫɦɨɬɪɟɧɧɵɯ ɞɥɹ ɷɬɨɣ ɰɟɥɢ ɩɪɢɛɨɪɨɜ, ɫɥɟɞɭɹ ɭɤɚɡɚɧɢɹɦ ɢɡɝɨɬɨɜɢɬɟɥɹ. 4.3 Ɍɟɯɧɢɱɟɫɤɨɟ ɨɛɫɥɭɠɢɜɚɧɢɟ ɉɟɪɢɨɞɢɱɟɫɤɢɟ ɩɪɨɜɟɪɤɢ Ⱦɥɹ ɨɛɟɫɩɟɱɟɧɢɹ ɷɮɮɟɤɬɢɜɧɨɣ ɪɚɛɨɬɵ ɚɝɪɟɝɚɬɚ ɜ ɬɟɱɟɧɢɟ ɩɪɨɞɨɥɠɢɬɟɥɶɧɨɝɨ ɜɪɟɦɟɧɢ ɧɟɨɛɯɨɞɢɦɨ ɨɛɟɫɩɟɱɢɬɶ ɜɵɩɨɥɧɟɧɢɟ ɫɢɥɚɦɢ ɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɯ ɫɩɟɰɢɚɥɢɫɬɨɜ ɫɥɟɞɭɸɳɢɯ ɩɪɨɜɟɪɨɤ: • ɗɥɟɦɟɧɬɵ ɭɩɪɚɜɥɟɧɢɹ ɢ ɩɪɟɞɨɯɪɚɧɢɬɟɥɶɧɵɟ ɭɫɬɪɨɣɫɬɜɚ ɞɨɥɠɧɵ ɪɚɛɨɬɚɬɶ ɩɪɚɜɢɥɶɧɨ. • Ɍɪɚɤɬ ɭɞɚɥɟɧɢɹ ɩɪɨɞɭɤɬɨɜ ɫɝɨɪɚɧɢɹ ɞɨɥɠɟɧ ɛɵɬɶ ɩɨɥɧɨɫɬɶɸ ɢɫɩɪɚɜɧɵɦ. • ɉɪɨɜɟɪɶɬɟ, ɱɬɨɛɵ ɜ ɬɪɭɛɚɯ ɩɨɞɚɱɢ ɬɨɩɥɢɜɚ ɢ ɜ ɨɛɪɚɬɧɨɣ ɬɪɭɛɟ ɧɟ ɛɵɥɨ ɡɚɫɨɪɨɜ, ɢ ɱɬɨɛɵ ɧɚ ɧɢɯ ɧɟ ɛɵɥɨ ɜɦɹɬɢɧ. • ɉɪɨɱɢɫɬɢɬɟ ɮɢɥɶɬɪ ɜ ɥɢɧɢɢ ɜɫɚɫɵɜɚɧɢɹ ɬɨɩɥɢɜɚ. • ɉɪɨɜɟɪɶɬɟ ɩɪɚɜɢɥɶɧɵɣ ɪɚɫɯɨɞ ɬɨɩɥɢɜɚ. • ȼɵɩɨɥɧɹɣɬɟ ɨɱɢɫɬɤɭ ɝɨɪɟɥɨɱɧɨɣ ɝɨɥɨɜɤɢ ɧɚ ɭɱɚɫɬɤɟ ɜɵɯɨɞɚ ɬɨɩɥɢɜɚ ɢ ɧɚ ɞɢɫɤɟ ɡɚɜɢɯɪɟɧɢɹ ɩɨɬɨɤɚ. • Ⱦɚɣɬɟ ɝɨɪɟɥɤɟ ɩɨɪɚɛɨɬɚɬɶ ɧɚ ɩɨɥɧɨɣ ɦɨɳɧɨɫɬɢ ɜ ɬɟɱɟɧɢɟ ɩɪɢɦɟɪɧɨ ɞɟɫɹɬɢ ɦɢɧɭɬ ɢ ɜɵɩɨɥɧɢɬɟ ɩɪɨɜɟɪɤɭ ɩɪɨɰɟɫɫɚ ɝɨɪɟɧɢɹ. ɉɪɨɜɟɪɶɬɟ: - ɧɚɫɬɪɨɣɤɭ ɜɫɟɯ ɷɥɟɦɟɧɬɨɜ, ɭɤɚɡɚɧɧɵɯ ɜ ɞɚɧɧɨɦ ɪɭɤɨɜɨɞɫɬɜɟ - ɬɟɦɩɟɪɚɬɭɪɭ ɞɵɦɨɜɵɯ ɝɚɡɨɜ ɜ ɞɵɦɨɜɨɣ ɬɪɭɛɟ - ɩɪɨɰɟɧɬɧɨɟ ɫɨɞɟɪɠɚɧɢɟ CO2 • ȼɨɡɞɭɯɨɜɨɞɵ (ɞɥɹ ɩɪɢɬɨɤɚ ɜɨɡɞɭɯɚ ɢ ɭɞɚɥɟɧɢɹ ɩɪɨɞɭɤɬɨɜ ɫɝɨɪɚɧɢɹ) ɞɨɥɠɧɵ ɛɵɬɶ ɫɜɨɛɨɞɧɵɦɢ ɨɬ ɤɚɤɢɯ-ɥɢɛɨ ɩɪɟɩɹɬɫɬɜɢɣ ɢ ɧɟ ɢɦɟɬɶ ɭɬɟɱɟɤ • Ƚɨɪɟɥɤɭ ɢ ɬɟɩɥɨɨɛɦɟɧɧɢɤ ɞɨɥɠɧɵ ɧɚɯɨɞɢɬɶɫɹ ɜ ɱɢɫɬɨɬɟ, ɧɚ ɧɢɯ ɧɟ ɞɨɥɠɧɨ ɛɵɬɶ ɧɚɤɢɩɢ. Ⱦɥɹ ɢɯ ɱɢɫɬɤɢ ɧɟ ɩɪɢɦɟɧɹɣɬɟ ɯɢɦɢɱɟɫɤɢɟ ɫɪɟɞɫɬɜɚ ɢɥɢ ɫɬɚɥɶɧɵɟ ɳɟɬɤɢ. • ȼɫɟ ɝɚɡɨɜɵɟ ɢ ɝɢɞɪɚɜɥɢɱɟɫɤɢɟ ɫɨɟɞɢɧɟɧɢɹ ɞɨɥɠɧɵ ɛɵɬɶ ɝɟɪɦɟɬɢɱɧɵɦɢ. • Ⱦɚɜɥɟɧɢɟ ɜɨɞɵ ɜ ɯɨɥɨɞɧɨɣ ɫɢɫɬɟɦɟ ɞɨɥɠɧɨ ɫɨɫɬɚɜɥɹɬɶ ɨɤɨɥɨ 1 ɛɚɪ; ɜ ɩɪɨɬɢɜɧɨɦ ɫɥɭɱɚɟ ɩɪɢɜɟɞɢɬɟ ɟɝɨ ɤ ɷɬɨɣ ɜɟɥɢɱɢɧɟ. • ɐɢɪɤɭɥɹɰɢɨɧɧɵɣ ɧɚɫɨɫ ɧɟ ɞɨɥɠɟɧ ɛɵɬɶ ɡɚɛɥɨɤɢɪɨɜɚɧɧɵɦ. • Ɋɚɫɲɢɪɢɬɟɥɶɧɵɣ ɛɚɤ (ɧɟ ɜɯɨɞɢɬ ɜ ɩɨɫɬɚɜɤɭ) ɞɨɥɠɟɧ ɛɵɬɶ ɡɚɩɨɥɧɟɧ. A ɑɢɫɬɤɭ ɤɨɠɭɯɚ, ɩɚɧɟɥɢ ɭɩɪɚɜɥɟɧɢɹ ɢ ɞɪɭɝɢɯ ɧɚɪɭɠɧɵɯ "ɷɫɬɟɬɢɱɟɫɤɢɯ" ɞɟɬɚɥɟɣ ɤɨɬɥɚ ɦɨɠɧɨ ɩɪɨɢɡɜɨɞɢɬɶ ɫ ɩɨɦɨɳɶɸ ɦɹɝɤɨɣ ɬɪɹɩɤɢ, ɫɦɨɱɟɧɧɨɣ ɜ ɦɵɥɶɧɨɦ ɪɚɫɬɜɨɪɟ ɜɨɞɵ. ɋɥɟɞɭɟɬ ɢɫɤɥɸɱɢɬɶ ɩɪɢ ɷɬɨɦ ɩɪɢɦɟɧɟɧɢɟ ɥɸɛɵɯ ɚɛɪɚɡɢɜɧɵɯ ɦɨɸɳɢɯ ɫɪɟɞɫɬɜ ɢ ɪɚɫɬɜɨɪɢɬɟɥɟɣ. Ɉɱɢɫɬɤɚ ɤɨɬɥɚ 1. Ɉɬɤɥɸɱɢɬɟ ɤɨɬɟɥ ɨɬ ɫɟɬɢ ɷɥɟɤɬɪɨɩɢɬɚɧɢɹ. 2. Ⱦɟɦɨɧɬɢɪɭɣɬɟ ɜɟɪɯɧɸɸ ɢ ɧɢɠɧɸɸ ɥɢɰɟɜɵɟ ɩɚɧɟɥɢ. 3. Ɉɬɤɪɨɣɬɟ ɞɜɟɪɰɭ, ɨɬɤɪɭɬɢɜ ɫɨɨɬɜɟɬɫɬɜɭɸɳɢɟ ɪɭɱɤɢ. 4. ɑɢɫɬɢɬɟ ɜɧɭɬɪɟɧɧɸɸ ɱɚɫɬɶ ɤɨɬɥɚ ɢ ɜɟɫɶ ɞɵɦɨɨɬɜɨɞɹɳɢɣ ɬɪɚɤɬ ɫ ɩɨɦɨɳɶɸ ɟɪɲɚ ɢɥɢ ɫɠɚɬɵɦ ɜɨɡɞɭɯɨɦ. 5. ȼɵɩɨɥɧɢɜ ɨɱɢɫɬɤɭ, ɡɚɤɪɨɣɬɟ ɞɜɟɪɰɭ ɢ ɡɚɤɪɟɩɢɬɟ ɟɟ ɫɨɨɬɜɟɬɫɬɜɭɸɳɟɣ ɪɭɱɤɨɣ. Ⱦɥɹ ɨɱɢɫɬɤɢ ɝɨɪɟɥɤɢ ɫɥɟɞɭɣɬɟ ɭɤɚɡɚɧɢɹɦ ɢɡɝɨɬɨɜɢɬɟɥɹ. 4.4 ɍɫɬɪɚɧɟɧɢɟ ɧɟɢɫɩɪɚɜɧɨɫɬɟɣ ɇɟɢɫɩɪɚɜɧɨɫɬɢ ȼɨ ɜɪɟɦɹ ɪɚɛɨɬɵ ɦɨɝɭɬ ɜɨɡɧɢɤɧɭɬɶ ɞɜɚ ɜɢɞɚ ɧɟɢɫɩɪɚɜɧɨɫɬɢ, ɩɪɢɱɢɧɚ ɤɨɬɨɪɵɯ ɦɨɠɟɬ ɛɵɬɶ ɭɫɬɪɚɧɟɧɚ ɩɨɥɶɡɨɜɚɬɟɥɟɦ: A Ȼɥɨɤɢɪɨɜɤɚ ɝɨɪɟɥɤɢ ɫ ɫɨɨɬɜɟɬɫɬɜɭɸɳɢɦ ɡɚɠɢɝɚɧɢɟɦ ɫɢɝɧɚɥɶɧɨɣ ɥɚɦɩɵ. ɋɦɨɬɪɟɬɶ ɪɭɤɨɜɨɞɫɬɜɨ ɩɨ ɷɤɫɩɥɭɚɬɚɰɢɢ ɝɨɪɟɥɤɢ. B ɋɪɚɛɚɬɵɜɚɧɢɟ ɩɪɟɞɨɯɪɚɧɢɬɟɥɶɧɨɝɨ ɬɟɪɦɨɫɬɚɬɚ ɜ ɫɥɭɱɚɟ ɩɨɜɵɲɟɧɢɹ ɬɟɦɩɟɪɚɬɭɪɵ ɜ ɤɨɬɥɟ ɞɨ ɜɟɥɢɱɢɧɵ, ɦɨɝɭɳɟɣ ɜɵɡɵɜɚɬɶ ɜɨɡɧɢɤɧɨɜɟɧɢɟ ɨɩɚɫɧɨɣ ɫɢɬɭɚɰɢɢ. Ⱦɥɹ ɜɨɫɫɬɚɧɨɜɥɟɧɢɹ ɧɨɪɦɚɥɶɧɵɯ ɪɚɛɨɱɢɯ ɭɫɥɨɜɢɣ ɨɬɤɪɭɬɢɬɟ ɩɪɨɛɤɭ ɪɢɫ. 1 ɢ ɧɚɠɦɢɬɟ ɩɨɞ ɧɟɣ ɤɧɨɩɤɭ ɫɛɪɨɫɚ. ȼ ɫɥɭɱɚɟ ɩɨɜɬɨɪɧɨɝɨ ɜɨɡɧɢɤɧɨɜɟɧɢɹ ɧɟɢɫɩɪɚɜɧɨɫɬɢ ɨɛɪɚɳɚɣɬɟɫɶ ɤ ɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɨɦɭ ɫɩɟɰɢɚɥɢɫɬɭ ɢɥɢ ɜ ɰɟɧɬɪ ɫɟɪɜɢɫɧɨɝɨ ɨɛɫɥɭɠɢɜɚɧɢɹ. ȼ ɫɥɭɱɚɟ ɧɟɢɫɩɪɚɜɧɨɣ ɢ/ɢɥɢ ɧɟɧɨɪɦɚɥɶɧɨɣ ɪɚɛɨɬɵ ɚɝɪɟɝɚɬɚ, ɜɵɤɥɸɱɢɬɟ ɟɝɨ ɢ ɜɨɡɞɟɪɠɢɜɚɣɬɟɫɶ ɨɬ ɥɸɛɨɣ ɩɨɩɵɬɤɢ ɫɚɦɨɫɬɨɹɬɟɥɶɧɨ ɨɬɪɟɦɨɧɬɢɪɨɜɚɬɶ ɢɥɢ ɭɫɬɪɚɧɢɬɶ ɩɪɢɱɢɧɭ ɧɟɢɫɩɪɚɜɧɨɫɬɢ. Ɉɛɪɚɳɚɣɬɟɫɶ ɢɫɤɥɸɱɢɬɟɥɶɧɨ ɩɪɨɮɟɫɫɢɨɧɚɥɶɧɨ ɩɨɞɝɨɬɨɜɥɟɧɧɨɦɭ ɢ ɚɜɬɨɪɢɡɨɜɚɧɧɨɦɭ ɩɟɪɫɨɧɚɥɭ.    

Страница 11 PDF

Страница 12

ATLAS 35 RU cod. 3540S123 - 07/2010 (Rev. 00) 5. ɏȺɊȺɄɌȿɊɂɋɌɂɄɂ ɂ ɌȿɏɇɂɱȿɋɄɂȿ ȾȺɇɇɕȿ 5.1 Ɋɚɡɦɟɪɵ, ɩɪɢɫɨɟɞɢɧɟɧɢɹ ɢ ɨɫɧɨɜɧɵɟ ɷɥɟɦɟɧɬɵ ɤɨɬɥɚ ɪɢɫ. 5 - Ɋɚɡɦɟɪɵ, ɩɪɢɫɨɟɞɢɧɟɧɢɹ ɢ ɨɫɧɨɜɧɵɟ ɷɥɟɦɟɧɬɵ ɤɨɬɥɚ a1 ɉɢɬɚɧɢɟ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ ɝɨɪɹɱɟɣ ɜɨɞɨɣ 3/4 a2 ɒɬɭɰɟɪ ɨɛɪɚɬɧɨɝɨ ɬɪɭɛɨɩɪɨɜɨɞɚ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ 1 1/2 a3 ɋɥɢɜ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ - 1/2” a4 ɉɨɞɤɥɸɱɟɧɢɟ ɞɵɦɨɯɨɞɚ a5 ɉɨɞɤɥɸɱɟɧɢɟ ɝɨɪɟɥɤɢ 34 ɒɚɪɢɤ ɬɟɪɦɨɦɟɬɪɚ ɫɢɫɬɟɦɵ ɨɬɨɩɥɟɧɢɹ ɢ ɩɪɟɞɨɯɪɚɧɢɬɟɥɶɧɨɝɨ ɭɫɬɪɨɣɫɬɜɚ 5.2 Ƚɢɞɪɚɜɥɢɱɟɫɤɨɟ ɫɨɩɪɨɬɢɜɥɟɧɢɟ ɫɢɫɬɟɦɵ ɋɨɩɪɨɬɢɜɥɟɧɢɟ ɜɨɞɹɧɨɝɨ ɤɨɧɬɭɪɚ ɪɢɫ. 6 - ɋɨɩɪɨɬɢɜɥɟɧɢɟ ɫɢɫɬɟɦɵ A ɦɛɚɪ B Ɋɚɫɯɨɞ ɜɨɞɵ ɥ/ɱ 5.3 Ɍɚɛɥɢɰɚ ɬɟɯɧɢɱɟɫɤɢɯ ɞɚɧɧɵɯ Ɇɨɞɟɥɶ °C ɦɦ a4 ɒ ɦɦ a5 ɒ ɦɦ ATLAS 32 400 120ɱ130 115 ATLAS 47 500 120ɱ130 115 ATLAS 62 600 120ɱ130 115 ATLAS 78 700 120ɱ130 115 ATLAS 95 800 120ɱ130 115                     Ɇɨɞɟɥɶ ATLAS 32 ATLAS 47 ATLAS 62 ATLAS 78 ATLAS 95 Ʉɨɥɢɱɟɫɬɜɨ ɷɥɟɦɟɧɬɨɜ n° 3 4 5 6 7 Ɇɚɤɫ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ kW 34.9 51.6 67.7 85.6 103.2 (Q) Ɇɢɧ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ kW 17.0 34.3 45.8 59.0 70.8 (Q) Ɇɚɤɫ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ ɜ ɪɟɠɢɦɟ ɨɬɨɩɥɟɧɢɹ kW 32 47 62 78 95 (P) Ɇɢɧ. ɬɟɩɥɨɜɚɹ ɦɨɳɧɨɫɬɶ ɜ ɪɟɠɢɦɟ ɨɬɨɩɥɟɧɢɹ kW 16 32 43 55 66 (P) Ʉɩɞ Pmax (80-60°C) % 91.7 91.1 91.5 91.1 92 Ʉɩɞ 30 % 94.3 93.5 94.0 93.5 93.8 Ʉɥɚɫɫ ɷɮɮɟɤɬɢɜɧɨɫɬɢ ɩɨ ɞɢɪɟɤɬɢɜɟ 92/42 EEC Ɇɚɤɫɢɦɚɥɶɧɨɟ ɪɚɛɨɱɟɟ ɞɚɜɥɟɧɢɟ ɜɨɞɵ ɜ ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ bar 6 6 6 6 6 (PMS) Ɇɚɤɫɢɦɚɥɶɧɨɟ ɪɚɛɨɱɟɟ ɞɚɜɥɟɧɢɟ ɜɨɞɵ ɜ ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ bar 0.8 0.8 0.8 0.8 0.8 Ɇɚɤɫɢɦɚɥɶɧɚɹ ɬɟɦɩɟɪɚɬɭɪɚ ɜ ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ °C 95 95 95 95 95 (tmax) Ɉɛɴɟɦ ɜɨɞɵ ɜ ɫɢɫɬɟɦɟ ɨɬɨɩɥɟɧɢɹ l 18 23 28 33 38 Ʉɥɚɫɫ ɡɚɳɢɬɵ IP X0D X0D X0D X0D X0D ɇɚɩɪɹɠɟɧɢɟ ɩɢɬɚɧɢɹ V/Hz 230/50 230/50 230/50 230/50 230/50 ȼɟɫ ɩɨɪɨɠɧɟɝɨ ɤɨɬɥɚ kg 127 166 205 244 283 Ⱦɥɢɧɚ ɤɚɦɟɪɵ ɫɝɨɪɚɧɢɹ mm 350 450 550 650 750 Ⱦɢɚɦɟɬɪ ɤɚɦɟɪɵ ɫɝɨɪɚɧɢɹ mm 300 300 300 300 300 ɋɨɩɪɨɬɢɜɥɟɧɢɟ ɞɵɦɨɨɬɜɨɞɹɳɟɝɨ ɬɪɚɤɬɚ mbar 0.2 0.27 0.4 0.4 0.63                 

Страница 12 PDF

Страница 13

ATLAS 36 RU cod. 3540S123 - 07/2010 (Rev. 00) 5.4 ɗɥɟɤɬɪɢɱɟɫɤɚɹ ɫɯɟɦɚ ɉɪɢɧɰɢɩɢɚɥɶɧɚɹ ɷɥɟɤɬɪɢɱɟɫɤɚɹ ɫɯɟɦɚ ATLAS 32-78 ɪɢɫ. 7 - ɉɪɢɧɰɢɩɢɚɥɶɧɚɹ ɷɥɟɤɬɪɢɱɟɫɤɚɹ ɫɯɟɦɚ ATLAS 32-78 Ʌɟɝɟɧɞɚ ɪɢɫ. 7 ɢ ɪɢɫ. 8 32 ɐɢɪɤɭɥɹɰɢɨɧɧɵɣ ɧɚɫɨɫ (ɢɫɤɥɸɱɟɧ ɢɡ ɩɨɫɬɚɜɤɢ) 49 ɉɪɟɞɨɯɪɚɧɢɬɟɥɶɧɵɣ ɬɟɪɦɨɫɬɚɬ 72 Ʉɨɦɧɚɬɧɵɣ ɬɟɪɦɨɫɬɚɬ (ɢɫɤɥɸɱɟɧ ɢɡ ɩɨɫɬɚɜɤɢ) 63 Ɍɟɪɦɨɫɬɚɬ ɪɟɝɭɥɢɪɨɜɤɢ ɤɨɬɥɚ 98 ȼɵɤɥɸɱɚɬɟɥɶ 211 Ɋɚɡɴɟɦ ɝɨɪɟɥɤɢ (ɢɫɤɥɸɱɟɧ ɢɡ ɩɨɫɬɚɜɤɢ) ɋɯɟɦɚ ɷɥɟɤɬɪɢɱɟɫɤɢɯ ɫɨɟɞɢɧɟɧɢɣ ATLAS 32-78 ɪɢɫ. 8 - ɋɯɟɦɚ ɷɥɟɤɬɪɢɱɟɫɤɢɯ ɫɨɟɞɢɧɟɧɢɣ ATLAS 32-78 ɉɪɢɧɰɢɩɢɚɥɶɧɚɹ ɷɥɟɤɬɪɢɱɟɫɤɚɹ ɫɯɟɦɚ ATLAS 95 ɪɢɫ. 9 - ɉɪɢɧɰɢɩɢɚɥɶɧɚɹ ɷɥɟɤɬɪɢɱɟɫɤɚɹ ɫɯɟɦɚ ATLAS 95 Ʌɟɝɟɧɞɚ ɪɢɫ. 9 ɢ ɪɢɫ. 10 32 ɐɢɪɤɭɥɹɰɢɨɧɧɵɣ ɧɚɫɨɫ (ɢɫɤɥɸɱɟɧ ɢɡ ɩɨɫɬɚɜɤɢ) 49 ɉɪɟɞɨɯɪɚɧɢɬɟɥɶɧɵɣ ɬɟɪɦɨɫɬɚɬ 72 Ʉɨɦɧɚɬɧɵɣ ɬɟɪɦɨɫɬɚɬ (ɢɫɤɥɸɱɟɧ ɢɡ ɩɨɫɬɚɜɤɢ) 98 ȼɵɤɥɸɱɚɬɟɥɶ 170 Ɍɟɪɦɨɫɬɚɬ ɪɟɝɭɥɢɪɨɜɤɢ ɬɟɦɩɟɪɚɬɭɪɵ 1-ɨɣ ɫɬɭɩɟɧɢ ɤɨɬɥɚ 171 Ɍɟɪɦɨɫɬɚɬ ɪɟɝɭɥɢɪɨɜɤɢ ɬɟɦɩɟɪɚɬɭɪɵ 2-ɨɣ ɫɬɭɩɟɧɢ ɤɨɬɥɚ 211 Ɋɚɡɴɟɦ ɝɨɪɟɥɤɢ (ɢɫɤɥɸɱɟɧ ɢɡ ɩɨɫɬɚɜɤɢ) ɋɯɟɦɚ ɷɥɟɤɬɪɢɱɟɫɤɢɯ ɫɨɟɞɢɧɟɧɢɣ ATLAS 95 ɪɢɫ. 10 - ɋɯɟɦɚ ɷɥɟɤɬɪɢɱɟɫɤɢɯ ɫɨɟɞɢɧɟɧɢɣ ATLAS 95          

Страница 13 PDF

Страница 14

Declaración de conformidad El fabricante: FERROLI S.p.A. Dirección: Via Ritonda 78/a 37047 San Bonifacio (Verona) declara que este equipo satisface las siguientes directivas CEE: • Directiva de Aparatos de Gas 90/396 • Directiva de Rendimientos 92/42 • Directiva de Baja Tensión 73/23 (modificada por la 93/68) • Directiva de Compatibilidad Electromagnética 89/336 (modificada por la 93/68) Presidente y representante legal Caballero del Trabajo Dante Ferroli ES Dichiarazione di conformità Il costruttore: FERROLI S.p.A. Indirizzo: Via Ritonda 78/a 37047 San Bonifacio VR dichiara che questo apparecchio è conforme alle seguenti direttive CEE: • Direttiva Apparecchi a Gas 90/396 • Direttiva Rendimenti 92/42 • Direttiva Bassa Tensione 73/23 (modificata dalla 93/68) • Direttiva Compatibilità Elettromagnetica 89/336 (modificata dalla 93/68) Presidente e Legale rappresentante Cav. del Lavoro Dante Ferroli IT Declaration of conformity Manufacturer: FERROLI S.p.A. Address: Via Ritonda 78/a 37047 San Bonifacio VR Italy declares that this unit complies with the following EU directives: • Gas Appliance Directive 90/396 • Efficiency Directive 92/42 • Low Voltage Directive 73/23 (amended by 93/68) • Electromagnetic Compatibility Directive 89/336 (amended by 93/68) President and Legal Representative Cav. del Lavoro Dante Ferroli TR Uygunluk beyani ømalatçi: FERROLI S.p.A. Adres: Via Ritonda 78/a 37047 San Bonifacio VR bu cihazin; asagida yer alan AET(EEC) yönergelerine uygunluk içinde oldugunu beyan etmektedir: • 90/396 Gazla çalistirilan üniteler için Yönetmelik • 92/42 Randiman/Verimlilik Yönetmeligi • Yönerge 73/23, Düsük Voltaj (93/68 nolu direktifle degisiklige ugratildi) • 89/336 Elektromanyetik Uygunluk Yönetmeligi (93/68 ile degisiklik yapilmistir) Baskan ve yasal temsilci øú. Dep. Dante Ferroli ES EN

Страница 14 PDF

Страница 15

Ⱦɟɤɥɚɪɚɰɢɹ ɫɨɨɬɜɟɬɫɬɜɢɹ ɂɡɝɨɬɨɜɢɬɟɥɶ: FERROLI S.p.A., ɚɞɪɟɫ: Via Ritonda 78/a 37047 San Bonifacio VR, ɡɚɹɜɥɹɟɬ, ɱɬɨ ɧɚɫɬɨɹɳɟɟ ɢɡɞɟɥɢɟ ɫɨɨɬɜɟɬɫɬɜɭɟɬ ɫɥɟɞɭɸɳɢɦ ɞɢɪɟɤɬɢɜɚɦ CEE: • Ⱦɢɪɟɤɬɢɜɚ ɩɨ ɝɚɡɨɜɵɦ ɩɪɢɛɨɪɚɦ 90/396 • Ⱦɢɪɟɤɬɢɜɚ ɩɨ Ʉ.ɉ.Ⱦ. 92/42 • Ⱦɢɪɟɤɬɢɜɚ ɩɨ ɧɢɡɤɨɦɭ ɧɚɩɪɹɠɟɧɢɸ 73/23 (ɫ ɢɡɦɟɧɟɧɢɹɦɢ, ɜɧɟɫɟɧɧɵɦɢ ɞɢɪɟɤɬɢɜɨɣ 93/68) • Ⱦɢɪɟɤɬɢɜɚ ɩɨ ɷɥɟɤɬɪɨɦɚɝɧɢɬɧɨɣ ɫɨɜɦɟɫɬɢɦɨɫɬɢ 89/336 (ɫ ɢɡɦɟɧɟɧɢɹɦɢ, ɜɧɟɫɟɧɧɵɦɢ ɞɢɪɟɤɬɢɜɨɣ 93/68). ɉɪɟɡɢɞɟɧɬ ɢ ɭɩɨɥɧɨɦɨɱɟɧɧɵɣ ɩɪɟɞɫɬɚɜɢɬɟɥɶ Ʉɚɜɚɥɶɟɪɟ ɞɟɥɶ ɥɚɜɨɪɨ (ɩɨɱɟɬɧɵɣ ɬɢɬɭɥ, ɩɪɢɫɭɠɞɚɟɦɵɣ ɝɨɫɭɞɚɪɫɬɜɨɦ ɡɚ ɡɚɫɥɭɝɢ ɜ ɪɭɤɨɜɨɞɫɬɜɟ ɩɪɨɦɵɲɥɟɧɧɨɫɬɶɸ) Dante Ferroli RU Conformiteitsverklaring De fabrikant: FERROLI S.p.A. Adres: Via Ritonda 78/a 37047 San Bonifacio VR verklaart dat dit apparaat conform is aan de volgende EEG richtlijnen: • Richtlijn Gastoestellen 90/396/EEG • Richtlijn Rendementseisen 92/42/EEG • Laagspanningsrichtlijn 73/23/EEG (gewijzigd door 93/68) • Richtlijn Elektromagnetische compatibiliteit 89/336/EEG (gewijzigd door 93/68) Voorzitter Raad van Bestuur en wettelijk vertegenwoordiger Onderscheiden voor verdiensten op economisch gebied Dante Ferroli ǻȒȜȦıȘ ıȣȝȝȩȡijȦıȘȢ ȅ țĮIJĮıțİȣĮıIJȒȢ: FERROLI S.p.A. ǻȚİȪșȣȞıȘ: Via Ritonda 78/a 37047 San Bonifacio VR įȘȜȫȞİȚ ȩIJȚ Ș ʌĮȡȠȪıĮ ıȣıțİȣȒ ıȪȝȝȠȡijȠȪIJĮȚ ȝİ IJȚȢ ĮțȩȜȠȣșȑȢ IJȦȞ ȠįȘȖȓİȢ ǼȅȀ: • OįȘȖȓĮ ıȣıțİȣȫȞ ıIJȠ ĮİȡȓȠȣ 90/396 • OįȘȖȓĮ ĮʌȠįȩıİȦȞ 92/42 • OįȘȖȓĮ ȤĮȝȘȜȒȢ TȐıȘȢ 73/23 (IJȡȠʌȠʌȠȚȘșİȓıĮ Įʌȩ IJȘȞ 93/68) • OįȘȖȓĮ HȜİțIJȡȠȝĮȖȞȘIJȚțȒȢ ȈȣȝȕĮIJȩIJȘIJĮȢ 89/336 (IJȡȠʌȠʌȠȚȘșİȓıĮ Įʌȩ IJȘȞ 93/68) Presidente e Legale rappresentante O ȆȡȠȑįȡȠȢ țĮȚ ȞȩȝȚȝȠȢ ȑțʌȡȩıȦʌȠȢ Dante Ferroli NL Déclaration de conformité Le constructeur : FERROLI S.p.A. Adresse: Via Ritonda 78/a 37047 San Bonifacio VR déclare que cet appareil est conforme aux directives CEE ci-dessous: • Directives appareils à gaz 90/396 • Directive rendements 92/42 • Directive basse tension 73/23 (modifiée 93/68) • Directive Compatibilité Electromagnétique 89/336 (modifiée 93/68) Président et fondé de pouvoirs Cav. du travail Dante Ferroli FR EL

Страница 15 PDF

Страница 16

FERROLI S.p.A. Via Ritonda 78/a 37047 San Bonifacio - Verona - ITALY www.ferroli.it

Страница 16 PDF

Инструкция Ferroli Инструкция Ferroli Atlas 32 95 | kotel.com.ua - запчастини для котлів