Страница 1
User Guide en United Kingdom Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Condensing System Boiler EcoBlue System 12 - 15 - 18 - 24 - 28 - 32
Страница 1 PDF
Страница 2
2 EcoBlue System 7219712 - 01 (04/15) Dear Customer, Thank you for purchasing this appliance. Please read this manual carefully before using the product and keep it in a safe place for future reference. In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained. Our Service and After Sales organization can assist with this. We hope you will receive many years of satisfactory service. The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk 0086 © Baxi Heating UK Ltd 2015 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988. Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick. CV34 4LL Full acknowledgement of author and source must be given. WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. Model Range Baxi EcoBlue 12 System ErP G.C.No 41-070-23 Baxi EcoBlue 15 System ErP G.C.No 41-070-24 Baxi EcoBlue 18 System ErP G.C.No 41-070-25 Baxi EcoBlue 24 System ErP G.C.No 41-070-26 Baxi EcoBlue 28 System ErP G.C.No 41-070-27 Baxi EcoBlue 32 System ErP G.C.No 41-470-28 Most illustrations in this document show the 12/15/18/24/28 models. Where the detail for 32 model differs it is described in the text or shown in a specific diagram. ISO 9001 FM 00866
Страница 2 PDF
Страница 3
EcoBlue System 3 Contents 7219712 - 01 (04/15) Contents 1 Introduction 1.1 General 1.2 Additional Documentation 1.3 Symbols Used 1.4 Abbreviations / Glossary 1.5 Liabilities 1.5.1 Manufacturer’s Liability 1.5.2 Installer’s Responsibility 1.5.3 User’s Responsibility 2 Safety 2.1 General Safety Instructions 2.2 Recommendations 2.2.1 Benchmark Commissioning Checklist 3 Technical Specifications 3.1 Technical Data 4 Description of the Product 4.1 General Description 4.2 Operating Principle 4.2.1 In Operation 4.3 Control Panel Description 4.4 Standard Delivery 4.5 Accessories & Options 4.5.1 Optional Extras 5 Operation 5.1 Shutdown 5.2 Frost Protection 5.3 Operation Checking Procedure & Basic Fault Identification 6 Settings 6.1 Setting the Boiler Temperature 6.1.1 Boiler Flow Temperature 6.1.2 Inactive Buttons 6.1.3 On/Off Selector Button 6.1.4 Information Display 7 Maintenance 7.1 General 7.2 Maintenance Instructions 7.3 Repressurising the System 7.4 Venting the System 7.5 Draining the System 5 5 5 5 6 6 6 7 7 8 8 9 9 10 10 12 12 12 12 13 14 14 14 15 15 15 16 18 18 18 18 18 18 19 19 19 20 21 22
Страница 3 PDF
Страница 4
4 EcoBlue System Contents 7219712 - 01 (04/15) 8 Troubleshooting 8.1 Error Codes 8.2 Fault Finding 9 Decommissioning 9.1 Decommissioning Procedure 10 Disposal 10.1 Disposal / Recycling 11 Environmental 11.1 Energy Saving 12 Warranty 12.1 General 12.2 Terms of Warranty 12.2.1 Standard Warranty Terms and Conditions 13 Appendix 13.1 ErP Information 13.1.1 Product Fiche - Boiler Space Heaters 13.1.2 Package Fiche - Boilers 23 23 24 25 25 25 25 26 26 27 27 27 27 29 29 29 30
Страница 4 PDF
Страница 5
EcoBlue System 5 Introduction 1 7219712 - 01 (04/15) 1 Introduction 1.1 General WARNING Installation, repair and maintenance must only be carried out only by a competent person. This document is intended for use by competent persons, All Gas Safe registered engineers carry an ID card with their licence number and a photograph. You can check your engineer is registered by telephoning 0800 408 5500 or online at www.gassaferegister.co.uk This manual is intended for the user of the Baxi EcoBlue System boiler. If the appliance is sold or transferred, or if the owner moves leaving the appliance behind you should ensure that the manual is kept with the appliance for consultation by the new owner and their installer. The appliance is designed as a boiler for use in residential domestic environments on a governed meter supply only. The selection of this boiler is entirely at the owner’s risk. If the appliance is used for purposes other than or in excess of these specifications, the manufacturer will not accept any liability for resulting loss, damage or injury. The manufacturer will not accept any liability whatsoever for loss, damage or injury arising as a result of failure to observe the instructions for use, maintenance and installation of the appliance. 1.2 Additional Documentation Various timers, external controls, etc. are available as optional extras. Full details are contained in the relevant sales literature. 1.3 Symbols Used In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, prevent hazards and guarantee correct operation of the appliance. DANGER Risk of a dangerous situation causing serious physical injury. WARNING Risk of a dangerous situation causing slight physical injury. CAUTION Risk of material damage. Signals important information . Signals a referral to other instructions or other pages in the instructions.
Страница 5 PDF
Страница 6
6 EcoBlue System 1 Introduction 7219712 - 01 (04/15) DHW: Domestic hot water CH: Central heating GB: Great Britain IE: Ireland BS: British standard HHIC: Heating and Hotwater Industry Council Pnc: Condensing output 1.4 Abbreviations / Glossary 1.5 Extent of Liabilities 1.5.1. Manufacturer's Liability Our products are manufactured in compliance with the requirements of the various european applicable Directives. They are therefore delivered with marking and all relevant documentation. In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice. The manufacturer will not accept any liability for loss, damage or injury arising as a result of:- Failure to abide by the instructions on using the appliance. Failure to regularly maintain the appliance, or faulty or inadequate maintenance of the appliance. Failure to abide by the instructions on installing the appliance. This company declares that no substances harmful to health are contained in the appliance or used during appliance manufacture. The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force, and only used in a suitably ventilated location. In GB, the installation must be carried out by a Gas Safe Registered Installer. It must be carried out in accordance with the current and relevant requirements of legislation and guidance. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. In IE, the installation must be carried out by a competent person and installed in accordance with the current edition of I.S. 813 ‘Domestic Gas Installations’, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. Incorrect installation could invalidate the warranty and may lead to prosecution.
Страница 6 PDF
Страница 7
EcoBlue System 7 Introduction 1 7219712 - 01 (04/15) 1.5.3. User's Responsibility To guarantee optimum operation of the installation, you must observe the following instructions: Read and observe the instructions given in the manuals supplied with the appliance. Seek the assistance of a qualified installer for the installation and initial commissioning. Ask the installer to explain the installation. Have the required annual inspection and maintenance carried out by a qualified installer and ensure the Benchmark Service Record in the Installation Manual is completed - this is a condition of the warranty ! Keep the manuals in good condition and near to the appliance. This appliance must not be used by people with a lack of experience or knowledge, unless they are supervised by someone familiar with the appliance or if they have been instructed on how to operate the appliance correctly. Do not allow children to operate or play with the appliance. 1.5.2 Installer's Responsibility The installer is responsible for the installation and initial start up of the appliance. The installer must adhere to the following instructions: Read and follow the instructions given in the manuals provided with the appliance. Carry out installation in compliance with the prevailing legislation and standards. Ensure the system is flushed and inhibitor added. Install the flue/chimney system correctly ensuring it is operational and complies with prevailing legislation and standards, regardless of location of the boiler’s installation. Only the installer should perform the initial start up and carry out any checks necessary. Explain the installation to the user. Complete the Benchmark Commissioning Checklist - this is a condition of the warranty ! Warn the user of the obligation to check the appliance and maintain it in good working order. Give all the instruction manuals to the user.
Страница 7 PDF
Страница 8
8 EcoBlue System 2 Safety 7219712 - 01 (04/15) WARNING Do not touch flue/chimney pipes. Depending on the settings of the appliance, the temperature of flue/chimney pipes may exceed 60 °C. Do not touch radiators for long periods. Depending on the settings of the appliance, the temperature of radiators may reach 85 °C. Take precautions with domestic hot water. Depending on the settings of the appliance, domestic hot water temperature may reach 65 °C. CAUTION Do not neglect to service the appliance. Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance. 2 Safety 2.1 General Safety Instructions ON OFF Water Gas Water DANGER If you smell gas: 1. Turn off the gas supply at the meter 2. Open windows and doors in the hazardous area 3. Do not operate light switches 4. Do not operate any electrical equipment 5. Do not use a telephone in the hazardous area 6. Extinguish any naked flame and do not smoke 7. Warn any other occupants and vacate the premises 8. Telephone the National Gas Emergency Service on:- 0800 111 999 If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves by turning their taps through 90° (1/4 turn) downwards For advice please contact your Installer, Annual Service Provider or Baxi Customer Support - The Service Division of Baxi. You can contact Baxi Customer Support on telephone number 0344 871 1525. When contacting Baxi Customer Support it will be useful to have the ‘Benchmark Checklist’ at the back of the Installation & Service Manual to hand as it includes details relevant to the boiler and installation.
Страница 8 PDF
Страница 9
EcoBlue System 9 Safety 2 7219712 - 01 (04/15) 2.2 Recommendations CAUTION Only qualified professionals are authorised to work on the appliance and the installation. The appliance has an integral frost protection mode as long as there is power to the boiler. Regularly check the water pressure in the system (recommended pressure is 1.5 bar). See section 7.4. Keep the appliance accessible at all times. Do not remove or cover the user information and serial number labels affixed to the boiler control flap. They must remain legible throughout the lifetime of the appliance 2.2.1 Benchmark Commissioning Checklist 1. Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). 2. All installations must be notified, by the installer, to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist. 3. This product should be serviced annually to optimise its safety, efficiency and performance. The service engineer should complete the relevant section of the Benchmark Service Record in the Installation & Service manual after each service. 4. The completed Benchmark Checklist & proof of annual servicing (where applicable) will be required in the event of any warranty work.
Страница 9 PDF
Страница 10
10 EcoBlue System 3 Technical Specifications 7219712 - 01 (04/15) 3 Technical Specifications 3.1 Technical Data 12/15/18/24/28 Central Heating Primary Circuit Pressures bar Safety Discharge 3 Max Operating 2.5 Min Operating 0.5 Recommended Operating Range 1-2 Temperatures Boiler Flow Temp (adjustable) 25°C to 80°C max (± 5°C) Electrical Supply 230V~ 50Hz (Appliance must be connected to an earthed supply) External Fuse Rating 3A NOTE: All data in this section are nominal values and subject to normal production tolerances. 150mm* Min 700mm 390mm 175 mm Min (300mm Min if using 80/125mm flueing system) 5mm Min 5mm Min In Operation 450mm Min 5mm Min 295mm For Servicing Purposes & Operating the Controls *This is MINIMUM recommended dimension. Greater clearance will aid installation and maintenance. Electrical Protection IPX5D (without integral timer) IP20 (with integral timer) Dimensions & Clearances These must be maintained in the event of any alteration in the property, e.g. additional cupboards etc.
Страница 10 PDF
Страница 11
EcoBlue System 11 Technical Specifications 3 7219712 - 01 (04/15) 3 Technical Specifications 3.1 Technical Data 32 Central Heating Primary Circuit Pressures bar Safety Discharge 3 Max Operating 2.5 Min Operating 0.5 Recommended Operating Range 1-2 Temperatures Boiler Flow Temp (adjustable) 25°C to 80°C max (± 5°C) Electrical Supply 230V~ 50Hz (Appliance must be connected to an earthed supply) External Fuse Rating 3A NOTE: All data in this section are nominal values and subject to normal production tolerances. Electrical Protection IPX5D (without integral timer) IPX20 (with integral timer) 5mm Min In Operation 450mm Min 345mm For Servicing Purposes & Operating the Controls 150mm* Min 763mm 450mm 175 mm Min (300mm Min if using 80/125mm flueing system) 5mm Min 5mm Min *This is MINIMUM recommended dimension. Greater clearance will aid installation and maintenance. Dimensions & Clearances These must be maintained in the event of any alteration in the property, e.g. additional cupboards etc.
Страница 11 PDF
Страница 12
12 EcoBlue System 7219712 - 01 (02/15) 4 Description of the Product 4 Description of the Product 4.1 General Description 1. The Baxi EcoBlue System boilers are fully automatic gas fired wall mounted condensing boilers. They are room sealed and fan assisted, and will serve central heating and stored domestic hot water. 2. The boiler is set to give a maximum output of :- 12 model - 12 kW 12.7 kW Pnc (Condensing) 15 model - 15 kW 15.9 kW Pnc (Condensing) 18 model - 18 kW 19 kW Pnc (Condensing) 24 model - 24 kW 25.4 kW Pnc (Condensing) 28 model - 28 kW 29.6 kW Pnc (Condensing) 32 model - 32 kW 33.8 kW Pnc (Condensing) 3. The boiler is factory set for use only on Natural Gas (G20). 4. The boiler model, serial number and Gas Council number are also shown on the information label behind the boiler control flap (Fig. 1). This is for user reference. The boiler is set by use of the button - see Section 6.1. Fig. 1 Boiler Control Flap User Label 4.2 Operating Principle Serial Number Label 4.2.1 In Operation 1. Whilst the boiler is in operation cooled flue gases are discharged through the flue gas discharge pipe. This may appear as a cloud of steam which is normal. 2. Condensed water is discharged from the boiler heat exchanger into a pipe (the condensate drain). This pipe must never be altered or re-routed except by a qualified professional.
Страница 12 PDF
Страница 13
7219712 - 01 (02/15) EcoBlue System 13 Description of the Product 4 4.3 Control Panel Description /R /P + + R R R Display Description Boiler Information View Standby - Reset - Esc R Standby - Reset - Esc Button Boiler Information View Button Increase CH Temperature Button Decrease CH Temperature Button Inactive Button Inactive Button On/Off Selector Button Key to Controls Display showing all available characters Boiler Flow Temperature Adjustment On/Off Selector Button When is displayed (Boiler On) the boiler will respond to timed Heating or Hot Water demand. N.B. If only is displayed the boiler will not operate ! THESE BUTTONS INACTIVE ! except when an outdoor sensor relay kit is connected DHW and CH OFF (frost protection still enabled) See Section 5.2 for information Indicates an error that prevents burner from igniting Error - Not resettable by user Water pressure too low Indicates an error resettable by the user Generic error Burner lit DHW mode (symbol will flash with demand) Heating mode (symbol will flash with demand) Units for temperature Units for pressure Except when an outdoor sensor relay kit is connected
Страница 13 PDF
Страница 14
14 EcoBlue System 7219712 - 01 (02/15) 4 Description of the Product 4.4 Standard Delivery 4.5 Accessories & Options 1. The literature pack contains: Literature pack • Installation & Servicing Manual • User Guide Instructions • Registration Card • Envelope • Fernox Leaflet • Wall Template • Product Leaflet • Package Leaflet 4.5.1 Optional Extras 1. Various timers, external controls, etc. are available as optional extras. Outdoor Sensor - Wired Mechanical Thermostat Mechanical Timer (24 hr) - Plug-in Digital Timer (7 day) - Plug-in Single Channel Timer - Wired Two Channel Timer - Wired RF Digital Programmable Room Unit - Wireless RF Mechanical Programmable Room Unit - Wireless Condensate Discharge Pump and Pipe ‘Trace Heating’ Flue Accessories (elbows, extensions, clamps etc.) (refer to the Flue Installation Guide supplied in the literature pack.) Remote relief valve kit Boiler discharge pump 1M Condensate Drain Pipe ‘Trace Heating’ Element 2M Condensate Drain Pipe ‘Trace Heating’ Element 3M Condensate Drain Pipe ‘Trace Heating’ Element 5M Condensate Drain Pipe ‘Trace Heating’ Element Any of the above MUST be fitted ONLY by a qualified competent person. Further details can be found in the relevant sales literature and at www.baxi.co.uk
Страница 14 PDF
Страница 15
7219712 - 01 (02/15) EcoBlue System 15 Operation 5 5.1 Shutdown 1. The boiler incorporates an integral frost protection feature that will operate in ‘On’ mode, and also when in standby mode ( displayed). 2. If the boiler temperature falls below 5°C, then the boiler will operate until the water temperature has been raised. 3. Further protection may be required for the system. Consult your installer for details. 5.2 Frost Protection 5 Operation 1. If it is anticipated that the boiler will not be used for a long period or the property is to be unoccupied it is recommended that the system drained if the electricity & gas supplies are to be turned off. Your installer will be able to offer advice.
Страница 15 PDF
Страница 16
16 EcoBlue System 7219712 - 01 (02/15) 5 Operation START Is there electricity to the boiler ? Is the display lit ? R Check electrical supply to boiler is switched on. NO YES Is the Burner Flame showing. R Burner Flame (Indicates burner is on) Boiler operating satisfactorily. NO YES YES Is the Timer ON and calling for heat ? Is the Room Thermostat (if fitted) set high enough ? 12 1 2 3 4 5 6 7 8 9 10 11 Typical examples of external timer Ensure timer is set for Central Heating ON (see any instructions supplied with timer) NO YES YES NO 15 10 5 20 25 15 10 5 20 25 Turn Room Thermostat to maximum setting (typical example shown) CH ON CH OFF bar 0 1 2 3 4 Is the Central Heating System Pressure between 0.7 and 2.5 bar ? If the reading* falls below 0.7 bar repressurise the system as described in section 7.4. NO R Error Code 118 showing low pressure. YES 5.3 Operation Checking Procedure & Basic Fault Identification Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). If the property has a prepayment meter ensure it has sufficient credit. NO If no gas, consult your supplier.
Страница 16 PDF
Страница 17
7219712 - 01 (02/15) EcoBlue System 17 Operation 5 YES Is the E and R symbol illuminated or flashing ? R /R /P + + R YES Press the Reset Button Error Symbol Reset Button If it does not reset CONTACT YOUR INSTALLER OR SERVICE ENGINEER. R Reset Symbol Is the Spanner symbol illuminated or flashing ? YES Spanner Symbol Error Code Flame Failure OR If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible *To display the water pressure press until is shown. will alternate with the system pressure. (NOTE: When the pump is running the gauge under the boiler may show a slightly different reading to the display)
Страница 17 PDF
Страница 18
18 EcoBlue System 7219712 - 01 (02/15) 6 Settings 6 Settings 6.1 Setting the Boiler Temperature 6.1.1 Boiler Flow Temperature To increase or decrease the boiler temperature:- 1. Press to increase the boiler flow temperature.* 2. Press to decrease the boiler flow temperature.* This sets the temperature at which the heated water flows from the boiler. The temperature of radiators and domestic hot water will depend upon the setting of various controls (e.g. Thermostatic Radiator Valves, cylinder thermostat). Your installer will be able to recommend the optimum boiler temperature setting, according to the controls fitted and your requirements. /R /P + + R R Display Screen 6.1.4 Information Display 1. The table opposite shows information that can be displayed by pressing the button. 2. Depending upon boiler model and any system controls connected to the appliance, not all information codes will be displayed and some that are will not have a value. 3. Press to return to the normal display. R Button Button R Boiler Flow Temperature Displayed* 6.1.2 Inactive Buttons* 1. Both and are inactive unless an outdoor sensor is connected. 6.1.3 On/Off Selector Button 1. Press button until the Boiler On mode symbol appears:- Boiler On mode N.B. If only is displayed the boiler will not operate ! See 6.1.1 to set the required temperature. Boiler Flow Temperature Adjustment On/Off Selector Button If and are pressed together P02 will be displayed. Pressing either button again will scroll through the display and P26 & P64 will be shown. Press to return to normal display. R The values displayed are the temperature as measured at the boiler, not necessarily that at the radiator or tap. Because of differences in systems, seasonal variations in mains water temperature etc. some adjustment of the temperatures may be required to achieve the desired results. Your installer will be able to offer advice. *Where Outdoor Sensor fitted If the control system includes an Outdoor Sensor the temperature display and Central Heating buttons perform different functions than those described. Display - This shows a simulated room temperature set point, NOT the boiler temperature. Buttons - They will alter the displayed temperature, and for optimum use should be used to change the displayed temperature to the same as selected on the room thermostat. By selecting a temperature different to the room thermostat altered comfort levels may be achieved. Buttons - When in DHW mode these buttons are active. The boiler flow temperature set point will be shown on the display - this must be AT LEAST the same temperature as the cylinder thermostat, and can be changed using these buttons. Your installer will be able to offer advice. THESE BUTTONS INACTIVE ! (except when an outdoor sensor relay kit is connected)
Страница 18 PDF
Страница 19
7219712 - 01 (02/15) EcoBlue System 19 Maintenance 7 7 Maintenance 7.1 General CAUTION Maintenance operations must be performed by a qualified competent person. Use only genuine spare parts. Taking out a maintenance contract is recommended. 2. The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 1. The central heating installation should be checked regularly. Proceed as follows: • Check the water pressure in the central heating installation. If the water pressure is lower than 0.7 bar, the water must be topped up. If necessary: top up the CH installation (recommended water pressure between 1 and 1.5 bar when system is cold). • Check radiators for leaks and (especially in damp areas) for rust. • Open and close the radiator valves several times a year to ensure they can still be rotated. • Only clean the outside of the boiler with a damp cloth. Do not use abrasive cleaning agents. 7.2 Maintenance Instructions CAUTION Only a qualified installer may clean the inside of the boiler. 1. The boiler does not require any special maintenance. However, the boiler must be serviced annually in accordance with the Installation and Service Manual and the relevant section of the Benchmark Service Record completed in order to maintain the warranty.
Страница 19 PDF
Страница 20
20 EcoBlue System 7219712 - 01 (02/15) 7 Maintenance 7.3 Re-pressurising the System 1. If the water pressure is too low, the installation must be re-pressurised. 2. The normal operating water pressure is between 1 and 2 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated (E117 displayed). Ensure that the filling loop is disconnected. Contact your installer. 3. It may be necessary to repressurise the system occasionally (when the water pressure falls below 0.7 or E118 displayed). A filling device (the filling loop) will be fitted on the system. Normally this will be situated on pipework close to the boiler. If the water pressure requires regular re-pressurising a fault or leak is indicated. Seek advice from your installer. 4. If you are unsure of its position, or cannot identify it, consult the installer who fitted the boiler. 5. The filling loop consists of two isolating taps and a separate filling pipe with connection fittings. 6. Only when repressurising should the filling pipe be connected between the two taps. Ensure that the nuts on the pipe ends are tightened onto the taps and the system is cold. 7. Fully open one of the taps first, and then while watching the pressure gauge, carefully open the second tap. 8. The system pressure is shown at all times on the pressure gauge and can be viewed on the display when there is power to the boiler. 9. To check the water pressure on the boiler display press until is shown. This will alternate with the system pressure. (When the pump is running the pressure gauge may show a slightly different reading to the display). 10. When the figures on the display or needle on the pressure gauge indicate between 1 and 1.5 bar turn both taps off. 11. Disconnect the filling pipe from the taps (a small amount of water may be present) and remove it. Keep the pipe in a safe place for future use. 12. If blanking caps are available fit them to the taps. Go to the ‘How to videos’ section of the ‘Information & advice’ page at www.baxi.co.uk for further details. 13. When the correct pressure is restored the boiler will reset automatically. bar 0 1 2 3 4 bar 0 1 2 3 4 Normal Pressure Requires Repressurising Pressure Gauge
Страница 20 PDF
Страница 21
7219712 - 01 (02/15) EcoBlue System 21 Maintenance 7 7.4 Venting the System 1. If any air is present in the appliance or system it must be removed in order to prevent nuisance noises that may occur during heating or when drawing off hot water. Proceed as follows: 1. Open the valves of all the radiators connected to the system. 2. Set the room thermostat to the highest possible temperature and any timers to ‘ON’. 3. Wait until the radiators are warm. 4. Switch off the boiler. 5. Vent the radiators. Work from the lowest radiator in the property. 6. Open the bleed vent with the key, keeping a cloth pressed against the vent. 7. Wait until water comes out of the bleed vent and then close. WARNING The CH water in the radiators will still be hot. 8. Switch the boiler on. 9. After venting, check that the water pressure in the system is still adequate. If the water pressure is lower than 0.7 bar, the water must be topped up. If necessary repressurise the system (recommended pressure between 1 and 1.5 bar). 10. Reset the room thermostat to the desired temperature. 7 6 A C B 5 4 3 2 1 2 3 4 1 10
Страница 21 PDF
Страница 22
22 EcoBlue System 7219712 - 01 (02/15) 7 Maintenance 7.5 Draining the System 1. It may be necessary to drain the CH system if radiators need to be replaced or removed, if there is a major water leak or if there is a risk of freezing. Proceed as follows: 1. Open the valves of all the radiators connected to the system. 2. Switch off or disconnect the boiler’s electrical isolation point (fused spur). 3. Wait until all the radiators are cold. 4. Connect a drain hose to the lowest draining point. Place the end of the hose in a drain or at a place where drained water will not cause any damage. 5. Open the CH system drain valve. Drain the system. WARNING The CH water may still be hot. 6. When water stops flowing from the draining point, close the draining valve. See Sections 7.4 & 7.5 for Re-pressurising & Venting the system. If in doubt seek advice from your installer. After draining and re-pressurising the concentration of system corrosion inhibitor and anti-freeze may become excessively diluted - seek advice from your installer. 5 4 3 2 1 2 3 4 1
Страница 22 PDF
Страница 23
7219712 - 01 (02/15) EcoBlue System 23 Troubleshooting 8 8 Troubleshooting 8.1 Error Codes 1. In the unlikely event of an error occurring the display will show one of two symbols or . In both cases the display will also show symbol and the numeric value of the error (see the ‘Table of Error Codes). 2. When the spanner is displayed the error cannot be reset by the user. Please contact your Installer, Annual Service Provider or Baxi Customer Support - The Service Division of Baxi to arrange your Annual Service. You can contact Baxi Customer Support on 0344 871 1525. When contacting Baxi Customer Support it will be useful to have the ‘Benchmark Checklist’ at the back of the Installation & Service Manual to hand as it includes details relevant to the boiler and installation. 3. fault errors can be reset by pressing the button and holding for two seconds. Error Codes 117 and 118 can be reset by restoring the correct system pressure as described in 7.4. /R /P + + R R Table Of Error Codes WARNING If an error code different from those described in the ‘Table of Error Codes’ appears on the display or a certain fault appears frequently, contact ‘Baxi Customer Support’. R R R Examples of Error Codes Display typically after reset Burner Flame (Indicates burner is on) When this symbol flashes a Domestic Hot Water or Central Heating demand is indicated Central Heating NTC Fault Flue NTC Fault Central Heating Return NTC Fault Safety Thermostat Operated (pump fault) Safety Thermostat Operated (over temperature) Primary System Water Pressure Too High Primary System Water Pressure Too Low Circulation Fault (Primary) Flame Failure (no lock-out) Flue NTC Operated Interruption Of Gas Supply or Flame Failure Flame Failure Fan or Fan Wiring Fault False Flame 20 28 40 110 111 117 118 125 128 130 133 151 160 384 R R R R R R
Страница 23 PDF
Страница 24
24 EcoBlue System 7219712 - 01 (02/15) 8 Troubleshooting 8.2 Fault Finding R Problem There is no domestic hot water. The radiators are cold. The boiler is not working. Possible Causes The boiler is not working. The water pressure is too low (< 0.5 bar). The temperature set point for the heating is too low. The heating mode is deactivated. The radiator valves are not open. The boiler is not working. The water pressure is too low (< 0.5 bar). The temperature set point for the heating is too low. No demand for heating. No power supply. The water pressure is too low (< 0.5 bar). The boiler is indicating an error. The gas pressure is too low. Condensate drain blocked. Solution Check that the boiler is being supplied with power. Check fuses and the switches. Check whether the gas valve is properly open. If the property has a prepayment meter ensure it has sufficient credit. Re-pressurise the system. Increase the value with the CH temperature button or if a room thermostat is connected, increase the temperature on the room thermostat. Activate the heating mode. Open the valves of all radiators connected to the system. Check that the boiler is being supplied with power. Check fuses and switches. Check whether the gas isolation valve is properly open. If the property has a prepayment meter ensure it has sufficient credit. Re-pressurise the system. Increase the value with the CH temperature button or if a room thermostat is connected, increase the temperature on the room thermostat. Ensure that timers & thermostats are calling for heat. Check that the boiler is being supplied with power. Check the fuses and switches. Re-pressurise the system. Press the Reset button Correct the error, if possible. Check whether the gas isolation valve is fully open. Open the gas isolation valve. Check drain, especially any external runs in freezing temperatures. 1. If the boiler is not working also check section 5.3 Operation Checking Procedure & Basic Fault Identification or contact your Installer.
Страница 24 PDF
Страница 25
7219712 - 01 (02/15) EcoBlue System 25 Decommissioning / Disposal 9/10 9 Decommissioning 9.1 Decommissioning Procedure 1. If you the boiler needs to be decommissioned either temporarily or permanently the following should be performed: • Switch off the boiler. • Switch off the boiler’s electrical connection. • Close the boiler gas valve. • Drain the CH system. See section 7.6 Draining the Installation CAUTION Only qualified professionals are authorised to work on the appliance and installation. 10 Disposal 10.1 Disposal / Recycling WARNING Removal and disposal of the boiler must be carried out by a qualified installer in accordance with local and national regulations.
Страница 25 PDF
Страница 26
26 EcoBlue System 7219712 - 01 (02/15) 11 Environmental 11 Environmental 11.1 Energy Saving Tips on saving energy: Do not cover radiators. Do not hang curtains in front of radiators. Install reflective panels behind the radiators to prevent heat losses. Insulate the pipes in rooms that are not heated (cellars and lofts). Install loft insulation & double glazing. Use draught excluders where necessary. Upgrade any older boiler external controls. Turn down room thermostats by 1° Close the radiators in rooms not in use. Do not run hot (or cold) water pointlessly. Fit a water-saving shower head to save up to 40 % energy. Take showers rather than baths. A bath consumes twice as much water and energy.
Страница 26 PDF
Страница 27
7219712 - 01 (02/15) EcoBlue System 27 Warranty 12 12 Warranty 12.1 General To make sure your boiler warranty is activated and maintained, it is essential that the: 1. Benchmark checklist is completed by your installer 2. Warranty is registered with Baxi 3. Boiler has an annual service Please note that failure to adhere to terms and conditions will make your warranty invalid. 12.2.1 Standard Warranty Terms and Conditions Warranty Registration, Service & Repair For full terms and conditions, visit www.baxi.co.uk/terms. Benchmark Checklist The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly. It can be found at the back of the installation and service manual and should be kept in a safe place for the life of the boiler. We will check that the Benchmark Checklist has been completed on an in-warranty visit. Ways to register your warranty If your boiler is eligible for an extended warranty, your installer may register the product on your behalf and provide you with the relevant documentation. Please check with your installer. Should this not be the case, you can register your warranty online at www.baxi.co.uk/registration 12.2 Terms of Warranty
Страница 27 PDF
Страница 28
28 EcoBlue System 7219712 - 01 (02/15) 12 Warranty Boiler Control Flap User Label Serial Number Label Annual Service A service must be completed every 12 months from the date of installation to maintain your warranty. This service must be completed by one of the following: • A Gas Safe registered installer/engineer • Baxi Customer Support; call us 0344 871 1525 Please make sure that your engineer has logged the service information at the back of the installation and service manual. You will be asked for your service history on any in-warranty repair visit. If you experience a problem with your boiler For any in or out of warranty repair, Baxi Customer Support is on hand to help you. Call our award-winning team to arrange for one of our nationwide team of Gas Safe registered engineers to visit. If your product is in warranty, everything is free of charge, subject to our warranty terms and conditions. If it is out of warranty, we can still help and offer a range of options you can choose from to suit your needs. Contact Baxi Customer Support 0344 871 1525 Opening hours Monday - Friday, 8.00am - 6.00pm Weekends and Bank Holidays, 8.30am - 2.00pm Please note calls may be recorded for training and monitoring purposes. When contacting Baxi Customer Support, please have the following information to hand: • Boiler serial number. This can be found on the appliance. • Proof of purchase if you do not have the boiler serial number. Please note that for in-warranty repairs, our engineers will ask to see your service history record, completed Benchmark Checklist and details of your installer. These can all be found in the installation and user manual.
Страница 28 PDF
Страница 29
EcoBlue System 29 Appendix 13 7219712 - 01 (04/15) 13 Appendix 13.1 ErP Information 13.1.1. Product Fiche - Boiler Space Heaters Product fiche for boiler space heaters Seasonal space heating energy efficiency class Rated heat output (Prated or Psup) Seasonal space heating energy efficiency Annual energy consumption Sound power level LWA indoors See For specific precautions about assembling, installing and maintaining, consult the relevant section as detailed on the Contents page. kW % kWh GJ dB A A A Baxi EcoBlue System ErP 12 15 18 24 28 32 A A A 12 93 93 93 93 93 93 15 18 24 28 32 10323 12903 15484 20645 24086 27527 37 46 56 74 87 99 55 55 56 53 56 59
Страница 29 PDF
Страница 30
30 EcoBlue System 13 Appendix 7219712 - 01 (04/15) 13.1.2. Package Fiche - Boilers Package fiche for boilers indicating the space heating energy efficiency of the package AD-3000743-01 % 1 ‘I’ 2 % + 3 % ( - ‘I’ ) x 0.1 = ± 4 % (‘III’ x + ‘IV’ x ) x 0.9 x ( /100) x = + (1) A* = 0.95, A = 0.91, B = 0.86, C = 0.83, D - G = 0.81 5 % ( - ‘I’ ) x ‘II’ = + 6 % 0.5 x 0.5 x = - 5 4 <30% G F E D C B A A + A ++ A +++ % + (50 x ‘II’) = 7 7 % e civ e d r alo s f o e h c fi m o rf p m u p t a e h y r a t n e m e l p p u S D N A n o it u b irt n o c r a l o S n o it u b irt n o c r a l o S d ella ts ni e c n o y c n eic fif e y g r e n e la u tc a sti o t d n o p s e rr o c t o n y a m e h c fi sih t ni r o f d e div o r p stc u d o r p f o e g a k c a p e h t f o y c n eic fif e y g r e n e e h T in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. ? C ° 5 3 t a s r e tti m e t a e h e r u t a r e p m e t w o l h ti w d e ll a t s n i p m u p t a e h y r a t n e m e l p p u s d n a r e li o B e g a k c a p f o s s a l c y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S R O ) % ni( y c n eic fif e y g r e n e g nit a e h e c a p s la n o s a e S p m u p t a e h y r a t n e m e l p p u S g nit a r k n a T ni( y c n eic fif e r o tc ello C %) )³ m ni( e m ulo v k n a T )² m ni( e zis r o tc ello C ) % ni( y c n eic fif e y g r e n e g nit a e h e c a p s la n o s a e S r e li o b y r a t n e m e l p p u S , % 5 . 1 = III s s al C , % 2 = II s s al C , % 1 = I s s al C Class IV = 2%, Class V = 3%, Class VI = 4%, Class VII = 3.5%, Class VIII = 5% l o rt n o c e r u t a r e p m e T r e li o b f o y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S 5 9 . 0 e s u , A e v o b a si g nit a r k n a t fI ) 1 ( e ula v r ella m s tc ele s p m u p t a e h f o e h c fi m o rf p m u p t a e h f o e h c fi m o rf r elio b f o e h c fi m o rf lo rt n o c e r u t a r e p m e t f o e h c fi m o rf I The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. II The factor for weighting the heat output of preferential and supple mentary heaters of a package as set out in the following table.
Страница 30 PDF
Страница 31
EcoBlue System 31 Appendix 13 7219712 - 01 (04/15) 13.1.2. Package Fiche - Boilers (cont) Package efficiency Temperature control X Baxi EcoBlue System ErP % Temperature control Y % The value of the mathematical expression: 294/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater. The value of the mathematical expression 115/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater. Weighting of boilers 0 0 0 0.1 0.3 0.37 0.2 0.55 0.70 0.3 0.75 0.85 0.4 0.85 0.94 0.5 0.95 0.98 0.6 0.98 1.00 ≥ 0.7 1.00 1.00 (1) The intermediate values are calculated by linear interpolation between the two adjacent values. (2) Prated is related to the preferential space heater or combination heater. III IV I V Psup / (Prated + Psup)(1)(2) II, package without hot water storage tank II, package with hot water storage tank 12 15 18 32 24 28
Страница 31 PDF
Страница 32
7219712 - 01 (04/15) 0086 Baxi Customer Support 0344 871 1525 Opening hours Monday - Friday, 8.00am-6.00pm Weekends and Bank Holidays, 8.30am-2.00pm Please note calls may be recorded for training and monitoring purposes baxi.co.uk Register now to activate your warranty: www.baxi.co.uk/registration For the warranty to be maintained, please make sure... Benchmark checklist is completed Warranty is registered with Baxi The boiler has an annual service 1 2 3 For full terms and conditions, visit www.baxi.co.uk/terms. Failure to adhere to terms and conditions will void your manufacturer’s warranty. Baxi Brooks House, Coventry Road, Warwick, CV34 4LL Please ensure the boiler is installed in accordance with these installation instructions and that you adhere to the Building Regulations. e&oe All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request.