EcoBlue Advance Heat User Guide Gas Fired Wall Mounted Condensing Boiler en United Kingdom 13 - 16 - 19 - 25 - 30 Please keep these instructions in a safe place. If you move house please hand them over to the next occupier.
Страница 1 PDF
Страница 2
2 EcoBlue Advance Heat 7219720 - 04 (05/16) Dear Customer, Thank you for purchasing this appliance. Please read this manual carefully before using the product and keep it in a safe place for future reference. In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained. Our Service and After Sales organization can assist with this. We hope you will receive many years of satisfactory service. The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk 0086 © Baxi Heating UK Ltd 2016 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988. Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick. CV34 4LL Full acknowledgement of author and source must be given. WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. Model Range Baxi EcoBlue Advance 13 Heat ErP G.C.No 41 470 34 Baxi EcoBlue Advance 16 Heat ErP G.C.No 41 470 35 Baxi EcoBlue Advance 19 Heat ErP G.C.No 41 470 36 Baxi EcoBlue Advance 25 Heat ErP G.C.No 41 470 37 Baxi EcoBlue Advance 30 Heat ErP G.C.No 41 470 38 ISO 9001 FM 00866
Страница 2 PDF
Страница 3
7219720 - 04 (05/16) EcoBlue Advance Heat 3 Contents Contents 1 Introduction 1.1 General 1.2 Additional Documentation 1.3 Symbols Used 1.4 Abbreviations / Glossary 1.5 Extent of Liabilities 1.5.1 Manufacturer’s Liability 1.5.2 Installer’s Responsibility 1.5.3 User’s Responsibility 2 Safety 2.1 General Safety Instructions 2.2 Recommendations 2.2.1 Benchmark Commissioning Checklist 3 Technical Specifications 3.1 Technical Data 3.1.1 Clearances 4 Description of the Product 4.1 General Description 4.2 Operating Principle 4.2.1 In Operation 4.3 Control Panel Description 4.3.1 User Interaction Controller 4.3.2 Indicator Lights 4.4 Standard Delivery 4.5 Accessories & Options 4.5.1 Optional Extras 5 Operation 5.1 Operation Checking Procedure & Basic Fault Identification 5.2 Shutdown 5.3 Frost Protection 6 Settings 6.1 Setting the Boiler Flow Temperature 7 Maintenance 7.1 General 7.2 Maintenance Instructions 7.3 Filling the System 7.4 Venting the System 7.5 Draining the System 6 6 6 6 7 7 7 8 8 9 9 10 10 11 11 12 13 13 13 13 14 14 14 15 15 15 16 16 18 18 18 18 19 19 19 20 21 22
Страница 3 PDF
Страница 4
4 EcoBlue Advance Heat 7219720 - 04 (05/16) Contents 8 Troubleshooting 8.1 Fault Warning & Lock-out Codes 8.2 Fault Finding 9 Decommissioning 9.1 Decommissioning Procedure 10 Disposal 10.1 Disposal / Recycling 11 Environmental 11.1 Energy Saving 11.2 Room Thermostats and Settings 12 Warranty 12.1 General 12.2 Terms of Warranty 12.2.1 Standard Warranty Terms and Conditions 13 Appendix 13.1 ErP Information 13.1.1 Product Fiche - Boiler Space Heaters 13.1.2 Package Fiche - Boilers 23 23 24 25 25 25 25 26 26 26 27 27 27 27 29 29 29 30
Страница 4 PDF
Страница 5
7219720 - 04 (05/16) EcoBlue Advance Heat 5 This page is intentionally blank
Страница 5 PDF
Страница 6
WARNING Installation, repair and maintenance must only be carried out only by a competent person. This document is intended for use by competent persons, All Gas Safe registered engineers carry an ID card with their licence number and a photograph. You can check your engineer is registered by telephoning 0800 408 5500 or online at www.gassaferegister.co.uk This manual is intended for the user of the Baxi EcoBlue Advance Heat boiler. If the appliance is sold or transferred, or if the owner moves leaving the appliance behind you should ensure that the manual is kept with the appliance for consultation by the new owner and their installer. The appliance is designed as a boiler for use in residential domestic environments on a governed meter supply only. The selection of this boiler is entirely at the owner’s risk. If the appliance is used for purposes other than or in excess of these specifications, the manufacturer will not accept any liability for resulting loss, damage or injury. The manufacturer will not accept any liability whatsoever for loss, damage or injury arising as a result of failure to observe the instructions for use, maintenance and installation of the appliance. 6 EcoBlue Advance Heat 7219720 - 04 (05/16) 1 Introduction 1 Introduction 1.1 General 1.2 Additional Documentation 1.3 Symbols Used WARNING Installation, repair and maintenance must only be carried out only by a competent person. This document is intended for use by competent persons, Various timers, external controls, etc. are available as optional extras. Full details are contained in the relevant sales literature. In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, prevent hazards and guarantee correct operation of the appliance. DANGER Risk of a dangerous situation causing serious physical injury. WARNING Risk of a dangerous situation causing slight physical injury. CAUTION Risk of material damage. Signals important information. Signals a referral to other instructions or other pages in the instructions.
Страница 6 PDF
Страница 7
7219720 - 04 (05/16) EcoBlue Advance Heat 7 Introduction 1 DHW: Domestic Hot Water CH: Central Heating GB: Great Britain IE: Ireland BS: British Standard HHIC: Heating and Hotwater Industry Council 1.4 Abbreviations / Glossary 1.5 Extent of Liabilities 1.5.1. Manufacturer's Liability Our products are manufactured in compliance with the requirements of the various european applicable Directives. They are therefore delivered with marking and all relevant documentation. In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice. The manufacturer will not accept any liability for loss, damage or injury arising as a result of:- Failure to abide by the instructions on using the appliance. Failure to regularly maintain the appliance, or faulty or inadequate maintenance of the appliance. Failure to abide by the instructions on installing the appliance. This company declares that no substances harmful to health are contained in the appliance or used during appliance manufacture. The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force, and only used in a suitably ventilated location. In GB, the installation must be carried out by a Gas Safe Registered Installer. It must be carried out in accordance with the current and relevant requirements of legislation and guidance. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. In IE, the installation must be carried out by a competent person and installed in accordance with the current edition of I.S. 813 ‘Domestic Gas Installations’, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. Incorrect installation could invalidate the warranty and may lead to prosecution.
Страница 7 PDF
Страница 8
8 EcoBlue Advance Heat 7219720 - 04 (05/16) 1 Introduction 1.5.2 Installer's Responsibility The installer is responsible for the installation and initial start up of the appliance. The installer must adhere to the following instructions: Read and follow the instructions given in the manuals provided with the appliance. Carry out installation in compliance with the prevailing legislation and standards. Ensure the system is flushed and inhibitor added. Install the flue/chimney system correctly ensuring it is operational and complies with prevailing legislation and standards, regardless of location of the boiler’s installation. Only the installer should perform the initial start up and carry out any checks necessary. Explain the installation to the user. Complete the Benchmark Commissioning Checklist in the Installation Manual - this is a condition of the warranty ! Warn the user of the obligation to check the appliance and maintain it in good working order. Give all the instruction manuals to the user. 1.5.3. User's Responsibility To guarantee optimum operation of the installation, you must observe the following instructions: Read and observe the instructions given in the manuals supplied with the appliance. Seek the assistance of a qualified installer for the installation and initial commissioning. Ask the installer to explain the installation. Have the required annual inspection and maintenance carried out by a qualified installer and ensure the Benchmark Service Record in the Installation Manual is completed - this is a condition of the warranty ! Keep the manuals in good condition and near to the appliance. This appliance must not be used by people with a lack of experience or knowledge, unless they are supervised by someone familiar with the appliance or if they have been instructed on how to operate the appliance correctly. Do not allow children to operate or play with the appliance.
Страница 8 PDF
Страница 9
WARNING Do not touch flue/chimney pipes. Depending on the settings of the appliance, the temperature of flue/chimney pipes may exceed 60 °C. Do not touch radiators for long periods. Depending on the settings of the appliance, the temperature of radiators may reach 85 °C. Take precautions with domestic hot water. Depending on the settings of the appliance, domestic hot water temperature may reach 65 °C. CAUTION Do not neglect to service the appliance. Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance. 7219720 - 04 (05/16) EcoBlue Advance Heat 9 Safety 2 2 Safety 2.1 General Safety Instructions The boiler can be isolated at the gas valve under the appliance by turning the tap through 90° (1/4 turn). For advice please contact your Installer, Annual Service Provider or Baxi Customer Support - The Service Division of Baxi. You can contact Baxi Customer Support on telephone number 0344 871 1545. When contacting Baxi Customer Support it will be useful to have the ‘Benchmark Checklist’ at the back of the Installation & Service Manual to hand as it includes details relevant to the boiler and installation. DANGER If you smell gas: 1. Turn off the gas supply at the meter 2. Open windows and doors in the hazardous area 3. Do not operate light switches 4. Do not operate any electrical equipment 5. Do not use a telephone in the hazardous area 6. Extinguish any naked flame and do not smoke 7. Warn any other occupants and vacate the premises 8. Telephone the National Gas Emergency Service on:- 0800 111 999 WARNING This boiler can be used by children aged 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge when they have been given supervision or instruction concerning the safe use of the device and understand the resulting risks. Children must not be allowed to play with the appliance. Cleaning and user maintenance must not be caried out by children without supervision.
Страница 9 PDF
Страница 10
10 EcoBlue Advance Heat 7219720 - 04 (05/16) 2 Safety 2.2 Recommendations CAUTION Only qualified professionals are authorised to work on the appliance and the installation. For sealed systems regularly check the water pressure in the system (recommended pressure is 1.5 bar). Your installer will advise on the method of repressurising if required. Keep the appliance accessible at all times. Do not remove or cover the serial number label affixed to the slide-out flap at the boiler lower left. It must remain legible throughout the lifetime of the appliance. 2.2.1 Benchmark Commissioning Checklist 1. Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). 2. All installations must be notified, by the installer, to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist. 3. This product should be serviced annually to optimise its safety, efficiency and performance. The service engineer should complete the relevant section of the Benchmark Service Record in the Installation & Service manual after each service. 4. The completed Benchmark Checklist & proof of annual servicing (where applicable) will be required in the event of any warranty work. See Section 12 for warranty information.
Страница 10 PDF
Страница 11
7219720 - 04 (05/16) EcoBlue Advance Heat 11 Technical Specifications 3 3 Technical Specifications 3.1 Technical Data NOTE: All data in this section are nominal values and subject to normal production tolerances. Outercase Dimensions Overall Height Inc Flue Elbow - 790mm Casing Height - 625mm Casing Width - 370mm Casing Depth - 280mm Electrical Supply 230V~ 50Hz (Appliance must be connected to an earthed supply) External Fuse Rating 3A Clearances Both Sides 5mm Min Above Casing (Top Flue) 190mm Min Above Casing (Rear Flue) 35mm Min Below Casing (in Cupboard) 35mm Min Below Casing 120mm Min Front (For Servicing) 500mm Min Front (In Operation) 5mm Min Flow Temperature (adjustable) 30° C to 80° C (± 5° C) Ventilation of Compartment Where the boiler is installed in a cupboard or compartment, no air vents are required for cooling purposes providing that the minimum dimensions above are maintained. Power Consumption 13 model 17W 16 model 20W 19 model 23W 25 model 33W 30 model 44W
Страница 11 PDF
Страница 12
12 EcoBlue Advance Heat 7219720 - 04 (05/16) 3 Technical Specifications 3.1.1. Clearances 1. A flat vertical area is required for the installation of the boiler. 2. These dimensions include the necessary clearances around the boiler for case removal, spanner access and air movement (Figs. 1 & 2). Additional clearances may be required for the passage of pipes around local obstructions such as joists running parallel to the front face of the boiler. 625mm 370mm 190 mm 5mm Min 5mm Min For Servicing Purposes In Operation 5mm Min 625mm 370mm 5mm Min 5mm Min For Servicing Purposes 5mm Min In Operation At least 1.5° At least 1.5° Fig. 1 Fig. 2 120mm Min 120mm Min 35mm Min in Cupboard 500mm Min 500mm Min 270mm 35mm Min in Cupboard 35mm Min* in cupboard (cut-outs required for pipework) 85mm Min* below ceiling (allows access to compression fittings on pipe)
Страница 12 PDF
Страница 13
7219720 - 04 (05/16) EcoBlue Advance Heat 13 Description of the Product 4 4 Description of the Product 4.1 General Description 1. The Baxi EcoBlue Advance Heat is a wall mounted condensing boiler which is room sealed and fan assisted, and will serve central heating and stored domestic hot water 2. The boiler will be one of the following outputs:- 13 kW 16 kW 19 kW 25 kW 30 kW 3. The boiler is factory set for use only on Natural Gas (G20). 4. The boiler model, serial number and Gas Council number are shown on the information label under the boiler (Fig. 3). This is for user reference. Fig. 3 Information Label 4.2 Operating Principle Slide Forward 4.2.1 In Operation 1. Whilst the boiler is in operation cooled flue gases are discharged through the flue gas discharge pipe. This may appear as a cloud of steam which is normal. 2. Condensed water is discharged from the boiler heat exchanger into a pipe (the condensate drain). This pipe must never be altered or re-routed except by a qualified professional.
Страница 13 PDF
Страница 14
14 EcoBlue Advance Heat 7219720 - 04 (05/16) 4 Description of the Product 4.3 Control Panel Description 4.3.1 User Interaction Controller (Fig. 4) Key to symbols:- Heating Water Temperature Sweep Key and Status Signals Reset button and On/Off Signal 1. The User Interaction Controller has 2 illuminating push buttons which provide information about the operating condition of the boiler. 2. The RESET button illuminates green when the boiler receives a demand for CH or DHW. 3. The button can flash orange, green or red and at different frequencies. 4. The User Interaction Controller also has one rotary knob. The rotary knob is used to set the maximum flow temperature of the heating water. 5. The temperature selected by the rotary knob must be set to a higher temperature than the cylinder thermostat to achieve the required hot water demand. Fig. 4 4.3.2 Indicator Lights (Fig. 5) The colour of the status light on the boiler control panel and the number of times that it flashes indicates whether the boiler is working normally, has a problem or requires servicing. See Section 8.1. for details of the fault conditions. Boiler Operating The light will flash orange at EVERY heating demand. The number of flashes will correspond with the heat output of the boiler. This is normal and does not indicate a fault condition. During normal running illuminates green and blinks off momentarily every seven seconds approximately to show the boiler is running normally and supplying heat (Fig. 6). Error When flashing green light indicates that the boiler has detected a problem, and is attempting to resolve it. If it does not succeed the boiler will go into fault mode and display a red light. Defect When flashing red light indicates that the boiler has a fault. Press the RESET button for a minimum of 5 seconds to try and clear the fault condition. A lock-out condition can be re-set up to 5 times within one hour using the reset button. Any fault that occurs repeatedly should be fully investigated and appropriate remedial actions taken by your installer or Baxi Customer Support. If there is a continuous red light, contact your installer or Baxi Customer Support The lights will be OFF when there is no demand for heat. Fig. 5 The symbol indicates the Status Light ON. Time LED ON LED OFF 1 flash OFF Light ON (approx. 7 sec.) 1 flash OFF Time Normal Operation - The green light remains on for around seven seconds and then extinguishes briefly, repeating the sequence whilst the boiler is operating. Upper Horizontal Line = Light ON Lower Horizontal Line = Light OFF Fig. 6
Страница 14 PDF
Страница 15
7219720 - 04 (05/16) EcoBlue Advance Heat 15 Description of the Product 4 4.4 Standard Delivery 4.5 Accessories & Options 1. The literature pack contains: Literature pack • Installation & Servicing Manual (including ‘benchmark’) • User Guide Instructions • Flue Accessories & Fitting Guide • Registration Card • Fernox Leaflet • Wall Template • Product Leaflet • Package Leaflet 4.5.1 Optional Extras 1. Various items are available as optional extras. Flue Accessories (elbows, extensions, clamps etc.) (refer to the Flue Accessories & Fitting Guide supplied in the literature pack.) Remote relief valve kit 1M Condensate Drain Pipe ‘Trace Heating’ Element 2M Condensate Drain Pipe ‘Trace Heating’ Element 3M Condensate Drain Pipe ‘Trace Heating’ Element 5M Condensate Drain Pipe ‘Trace Heating’ Element Any of the above MUST be fitted ONLY by a qualified competent person. Further details can be found in the relevant sales literature and at www.baxi.co.uk
Страница 15 PDF
Страница 16
Is the Timer ON and calling for heat ? Is the Room Thermostat (if fitted) set high enough ? 12 1 2 3 4 5 6 7 8 9 10 11 Typical examples of external timer Ensure timer is set for Central Heating ON (see any instructions supplied with timer) NO YES NO 15 10 5 20 25 15 10 5 20 25 Turn Room Thermostat to maximum setting (typical example shown) CH ON CH OFF 16 EcoBlue Advance Heat 7219720 - 04 (05/16) 5 Operation 5 Operation START YES NO Boiler fails to light ? NO Press the Reset Button If boiler will not light. CONTACT YOUR INSTALLER OR SERVICE ENGINEER. Reset Button 5.1 Operation Checking Procedure & Basic Fault Identification Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). If the property has a prepayment meter ensure it has sufficient credit. NO If no gas, consult your supplier.
Страница 16 PDF
Страница 17
7219720 - 04 (05/16) EcoBlue Advance Heat 17 Operation 5 NO If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible Is there electricity to the boiler ? Check the fused spur to the boiler is in the on position. NO Ignition Spark will commence Boiler operating satisfactorily. YES YES Boiler flame established (Both lights are on) YES Reset Button/Light Chimney Sweep /On Button /Light YES If the boiler fails to operate. Contact your Installer. YES Switch on. NO
Страница 17 PDF
Страница 18
18 EcoBlue Advance Heat 7219720 - 04 (05/16) 5 Operation / Settings 5.2 Shutdown 1. To prevent radiators and the system from freezing in rooms where there is a risk of frost (e.g. a garage or storage room), a frost thermostat can be connected to the system 5.3 Frost Protection 1. If it is anticipated that the boiler will not be used for a long period or the property is to be unoccupied it is recommended that the system is drained if the electricity & gas supplies are to be turned off. Your installer will be able to offer advice. 6 Settings 6.1 Setting the Boiler Flow Temperature To increase or decrease the boiler temperature:- 1. Turn the rotary knob to the right (Fig. 7) to increase the boiler temperature. 2. Turn the rotary knob to the left (Fig. 7) to decrease the boiler temperature. 3. To achieve the required domestic hot water temperature the rotary knob must be set to a higher temperature than that selected on the cylinder thermostat. Rotary Knob - Boiler Temperature Adjustment Fig. 7 + -
Страница 18 PDF
Страница 19
7219720 - 04 (05/16) EcoBlue Advance Heat 19 Maintenance 7 7 Maintenance 7.1 General CAUTION Maintenance operations must be performed by a qualified competent person. Use only genuine spare parts. Taking out a maintenance contract is recommended. 2. The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 7.2 Maintenance Instructions CAUTION Only a qualified installer may clean the inside of the boiler. 1. The boiler does not require any special maintenance. However, the boiler must be serviced annually in accordance with the Installation and Service Manual and the relevant section of the Benchmark Service Record completed in order to maintain the warranty. 1. The central heating system should be checked regularly. Proceed as follows: For Sealed Systems If the water pressure is lower than 0.7 bar, the water must be topped up. If necessary: top up the CH system (recommended water pressure between 1 and 2 bar). • Check radiators for leaks and (especially in damp areas) for rust. • Open and close the radiator valves several times a year to ensure they can still be rotated. • Only clean the outside of the boiler with a damp cloth. Do not use abrasive cleaning agents.
Страница 19 PDF
Страница 20
20 EcoBlue Advance Heat 7219720 - 04 (05/16) 7 Maintenance 7.3 Filling the System The boiler will be installed on either an open-vented or sealed (pressurised) heating system. If you are unsure which type of system you have consult your installer. Sealed systems may require periodic re-pressurisation. If this is required on a regular basis a fault or leak is indicated. Seek advice from your installer.
Страница 20 PDF
Страница 21
7219720 - 04 (05/16) EcoBlue Advance Heat 21 Maintenance 7 7.4 Venting the System 8. Switch the boiler on. 9. After venting, if the system is of the sealed (pressurised) type check that the water pressure is still adequate. For sealed systems - if the water pressure is lower than 0.7 bar, the water must be topped up (recommended water pressure between 1.0 and 1.5 bar when the system is cold). 10. Reset the room thermostat to the desired temperature.. 7 6 A C B 5 4 3 2 1 2 3 4 1 10 If any air is present in the appliance or system it must be removed in order to prevent nuisance noises that may occur during operation. The boiler has an inbuilt auto air vent to aid the removal of air and is supplied in the open position. Proceed as follows: 1. Open the valves of all the radiators connected to the system. 2. Set the room thermostat to the highest possible temperature and any timers to ‘ON’. 3. Wait until the radiators are warm. 4. Switch off the boiler. 5. Vent the radiators. Work from the lowest radiator in the property. 6. Open the bleed vent with the key, keeping a cloth pressed against the vent. 7. Wait until water comes out of the bleed vent and then close. WARNING The CH water in the radiators will still be hot.
Страница 21 PDF
Страница 22
22 EcoBlue Advance Heat 7219720 - 04 (05/16) 7 Maintenance 7.5 Draining the System It may be necessary to drain the CH system if radiators need to be replaced or removed, if there is a major water leak or if there is a risk of freezing. Proceed as follows: 1. Open the valves of all the radiators connected to the system. 2. Switch off or disconnect the boiler’s electrical isolation point. 3. Wait until all the radiators are cold. 4. Connect a drain hose to the lowest draining point. Place the end of the hose in a drain or at a place where drained water will not cause any damage. 5. Open the CH system drain valve. Drain the system. WARNING The CH water may still be hot. 6. When water stops flowing from the draining point, close the draining valve. See Section 7.4 Venting the system. If in doubt seek advice from your installer. After draining the concentration of system corrosion inhibitor and anti-freeze may become excessively diluted - seek advice from your installer. 5 4 3 2 1 2 3 4 1
Страница 22 PDF
Страница 23
7219720 - 04 (05/16) EcoBlue Advance Heat 23 Troubleshooting 8 8 Troubleshooting 8.1 Fault Warning & Lock-out Codes Green Light Flashing Temperature Protection Sensor Error Shutdown Input Flame Loss Communication Fault Parameter Fault Miscellaneous High Temperature Protection Ignition Fault Fan Fault Parameter Fault Miscellaneous Red Light Flashing No. of Flashes 1 2 3 4 5 6 1. The colour of the status light on the boiler control panel and the number of times that it flashes indicates whether the boiler is working normally, has a problem or requires servicing. Fault - Warning When flashing green light indicates that the boiler has detected a problem, and is attempting to resolve it. If it does not succeed the boiler will go into lock-out mode and will display a red light. Fault - Lock-out When flashing red light indicates that the boiler has a fault and has locked out. Press the RESET button for a minimum of 5 seconds to try and clear the fault condition. 2. A lock-out condition can be re-set up to 5 times within one hour using the reset button. Any fault that repeats regularly should be fully investigated and appropriate remedial actions taken by your Installer, Annual Service Provider or Baxi Customer Support - The Service Division of Baxi. 3. If there is a continuous red light, contact your Installer, Annual Service Provider or Baxi Customer Support - The Service Division of Baxi, and inform them of the fault code displayed. 4. You can contact Baxi Customer Support on 0344 871 1545. When contacting Baxi Customer Support it will be useful to have the ‘Benchmark Checklist’ at the back of the Installation & Service Manual to hand as it includes details relevant to the boiler and installation. Time Time Time Time LED ON The symbol indicates the flashing Status Light. LED OFF LED ON LED OFF LED ON LED OFF LED ON LED OFF Time LED ON LED OFF Time LED ON LED OFF 1 flash 2 rapid flashes 3 rapid flashes 4 rapid flashes 5 rapid flashes 6 rapid flashes 1 flash 2 rapid flashes 3 rapid flashes 4 rapid flashes 5 rapid flashes 6 rapid flashes Time Time Time Time Time Time Normal Operation The symbol indicates the Status Light ON. Time LED ON LED OFF 1 flash OFF Light ON (approx. 7 sec.) 1 flash OFF Time Upper Horizontal Line = Light ON Lower Horizontal Line = Light OFF Upper Horizontal Line = Light ON Lower Horizontal Line = Light OFF
Страница 23 PDF
Страница 24
24 EcoBlue Advance Heat 7219720 - 04 (05/16) 8 Troubleshooting 8.2 Fault Finding 1. If the boiler is not working, check section 5.1 Operation Checking Procedure & Basic Fault Identification or the fault finding table. Contact your Installer. Problem There is no domestic hot water and/or the radiators are cold. The boiler is not working. The domestic hot water is not hot enough. The radiators are not hot enough. Possible Causes Check that the boiler is being supplied with power (all controls set to ON). Check the fuses and the switches. If possible check whether the gas cock is properly open. If the property has a prepayment meter ensure it has sufficient credit. Check if the Fault - Lock-out is illuminated. See Section 8.1 to reset. The boiler temperature setting is below the cylinder thermostat setting. The radiator valves are not open. The temperature set point for the heating is too low (check boiler & room thermostat).
Страница 24 PDF
Страница 25
7219720 - 04 (05/16) EcoBlue Advance Heat 25 Decommissioning / Disposal 9 / 10 9 Decommissioning 9.1 Decommissioning Procedure 10 Disposal 10.1 Disposal / Recycling 1. If your the boiler needs to be decommissioned either temporarily or permanently the following should be performed: • Switch off the boiler. • Switch off the boiler’s electrical connection. • Close the boiler gas valve. • Drain the CH system. Seek the advice of your installer. CAUTION Only qualified professionals are authorised to work on the appliance and system to decommission. WARNING Removal and disposal of the boiler must be carried out by a qualified installer in accordance with local and national regulations.
Страница 25 PDF
Страница 26
26 EcoBlue Advance Heat 7219720 - 04 (05/16) 11 Environmental 11 Environmental 11.1 Energy Saving 11.2 Room Thermostats and Settings Various models of room thermostats are available. The thermostat type and setting affect the total energy consumption. A few tips: Fully opening or closing thermostatic radiator valves result in unwanted temperature fluctuations. Turn the thermostat knob or valve higher or lower in small steps. Lower the thermostat to approximately 20°C. This reduces heating costs and energy consumption. When rooms are to be aired, lower the thermostat well in advance. When setting thermostats or programmers take account of days when nobody will be in and of holidays. Tips on saving energy: Do not cover radiators. Do not hang curtains in front of radiators. Install reflective panels behind the radiators to prevent heat losses. Insulate the pipes in rooms that are not heated (cellars and lofts). Install loft insulation & double glazing. Use draught excluders where necessary. Upgrade any older external controls. Turn down room thermostats by 1°C Turn off radiators in rooms not in use. Do not run hot (or cold) water pointlessly. Fit a water-saving shower head to save up to 40 % energy. Take showers rather than baths. A bath consumes twice as much water and energy.
Страница 26 PDF
Страница 27
7219720 - 04 (05/16) EcoBlue Advance Heat 27 Warranty 12 12 Warranty 12.1 General To make sure your boiler warranty is activated and maintained, it is essential that the: 1. Benchmark checklist is completed by your installer 2. Warranty is registered within 30 days 3. Boiler has an annual service Please note that failure to adhere to terms and conditions will make your warranty invalid. 12.2.1 Standard Warranty Terms and Conditions Warranty Registration, Service & Repair For full terms and conditions, visit www.baxi.co.uk/terms. Benchmark Checklist The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly. It can be found at the back of the installation and service manual and should be kept in a safe place for the life of the boiler. We will check that the Benchmark Checklist has been completed on an in-warranty visit. Ways to register your warranty If your boiler is eligible for an extended warranty, your installer may register the product on your behalf and provide you with the relevant documentation. Please check with your installer. Should this not be the case, you can register your warranty online at www.baxi.co.uk/registration 12.2 Terms of Warranty
Страница 27 PDF
Страница 28
28 EcoBlue Advance Heat 7219720 - 04 (05/16) 12 Warranty Information Label Slide Forward Annual Service A service must be completed every 12 months from the date of installation to maintain your warranty. This service must be completed by one of the following: • A Gas Safe registered installer/engineer • Baxi Customer Support; call us 0344 871 1545 Please make sure that your engineer has logged the service information at the back of the installation and service manual. You will be asked for your service history on any in-warranty repair visit. If you experience a problem with your boiler For any in or out of warranty repair, Baxi Customer Support is on hand to help you. Call our award-winning team to arrange for one of our nationwide team of Gas Safe registered engineers to visit. If your product is in warranty, everything is free of charge, subject to our warranty terms and conditions. If it is out of warranty, we can still help and offer a range of options you can choose from to suit your needs. Contact Baxi Customer Support 0344 871 1545 Opening hours Monday - Friday, 8.00am - 6.00pm Weekends and Bank Holidays, 8.30am - 2.00pm Please note calls may be recorded for training and monitoring purposes. When contacting Baxi Customer Support, please have the following information to hand: • Boiler serial number. This can be found on the appliance. • Proof of purchase if you do not have the boiler serial number. Please note that for in-warranty repairs, our engineers will ask to see your service history record, completed Benchmark Checklist and details of your installer. These can all be found in the installation and user manual.
Страница 28 PDF
Страница 29
7219720 - 04 (05/16) EcoBlue Advance Heat 29 Appendix 13 13 Appendix 13.1 ErP Information 13.1.1. Product Fiche - Boiler Space Heaters Product fiche for boiler space heaters Seasonal space heating energy efficiency class Rated heat output (Prated or Psup) Seasonal space heating energy efficiency Annual energy consumption Sound power level LWA indoors See For specific precautions about assembling, installing and maintaining, consult the relevant section as detailed on the Contents page. kW % kWh GJ dB A A A Baxi EcoBlue Advance Heat ErP 13 16 19 25 30 A A 13 16 30 25 19 93 93 93 93 93 11183 13764 25807 21506 16344 40 50 93 77 59 32 33 41 37 34
Страница 29 PDF
Страница 30
30 EcoBlue Advance Heat 7219720 - 04 (05/16) 13 Appendix 13.1.2. Package Fiche - Boilers Package fiche for boilers indicating the space heating energy efficiency of the package AD-3000743-01 % 1 ‘I’ 2 % + 3 % ( - ‘I’ ) x 0.1 = ± 4 % (‘III’ x + ‘IV’ x ) x 0.9 x ( /100) x = + (1) A* = 0.95, A = 0.91, B = 0.86, C = 0.83, D - G = 0.81 5 % ( - ‘I’ ) x ‘II’ = + 6 % 0.5 x 0.5 x = - 5 4 <30% G F E D C B A A + A ++ A +++ % + (50 x ‘II’) = 7 7 % e civ e d r alo s f o e h c fi m o rf p m u p t a e h y r a t n e m e l p p u S D N A n o it u b irt n o c r a l o S n o it u b irt n o c r a l o S d ella ts ni e c n o y c n eic fif e y g r e n e la u tc a sti o t d n o p s e rr o c t o n y a m e h c fi sih t ni r o f d e div o r p stc u d o r p f o e g a k c a p e h t f o y c n eic fif e y g r e n e e h T in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. ? C ° 5 3 t a s r e tti m e t a e h e r u t a r e p m e t w o l h ti w d e ll a t s n i p m u p t a e h y r a t n e m e l p p u s d n a r e li o B e g a k c a p f o s s a l c y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S R O ) % ni( y c n eic fif e y g r e n e g nit a e h e c a p s la n o s a e S p m u p t a e h y r a t n e m e l p p u S g nit a r k n a T ni( y c n eic fif e r o tc ello C %) )³ m ni( e m ulo v k n a T )² m ni( e zis r o tc ello C ) % ni( y c n eic fif e y g r e n e g nit a e h e c a p s la n o s a e S r e li o b y r a t n e m e l p p u S , % 5 . 1 = III s s al C , % 2 = II s s al C , % 1 = I s s al C Class IV = 2%, Class V = 3%, Class VI = 4%, Class VII = 3.5%, Class VIII = 5% l o rt n o c e r u t a r e p m e T r e li o b f o y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S 5 9 . 0 e s u , A e v o b a si g nit a r k n a t fI ) 1 ( e ula v r ella m s tc ele s p m u p t a e h f o e h c fi m o rf p m u p t a e h f o e h c fi m o rf r elio b f o e h c fi m o rf lo rt n o c e r u t a r e p m e t f o e h c fi m o rf I The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. II The factor for weighting the heat output of preferential and supple mentary heaters of a package as set out in the following table.
Страница 30 PDF
Страница 31
7219720 - 04 (05/16) EcoBlue Advance Heat 31 Appendix 13 13.1.2. Package Fiche - Boilers (cont) Package efficiency Temperature control X Baxi EcoBlue Advance Heat ErP % Temperature control Y % The value of the mathematical expression: 294/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater. The value of the mathematical expression 115/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater. Weighting of boilers 0 0 0 0.1 0.3 0.37 0.2 0.55 0.70 0.3 0.75 0.85 0.4 0.85 0.94 0.5 0.95 0.98 0.6 0.98 1.00 ≥ 0.7 1.00 1.00 (1) The intermediate values are calculated by linear interpolation between the two adjacent values. (2) Prated is related to the preferential space heater or combination heater. III IV I V Psup / (Prated + Psup)(1)(2) II, package without hot water storage tank II, package with hot water storage tank 13 16 19 30 25
Страница 31 PDF
Страница 32
7219720 - 04 (05/16) 0086 Baxi Customer Support 0344 871 1545 Opening hours Monday - Friday, 8.00am-6.00pm Weekends and Bank Holidays, 8.30am-2.00pm Please note calls may be recorded for training and monitoring purposes baxi.co.uk Register now to activate your warranty: www.baxi.co.uk/registration For the warranty to be maintained, please make sure... Benchmark checklist is completed Warranty is registered within 30 days The boiler has an annual service 1 2 3 For full terms and conditions, visit www.baxi.co.uk/terms. Failure to adhere to terms and conditions will void your manufacturer’s warranty. Baxi Brooks House, Coventry Road, Warwick, CV34 4LL Please ensure the boiler is installed in accordance with these installation instructions and that you adhere to the Building Regulations. e&oe All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request.
Страница 32 PDF