Please keep these instructions in a safe place. If you move house please hand them over to the next occupier. United Kingdom en User Guide High Efficiency Wall Hung Condensing Gas Boiler Baxi System 615 - 618 - 624 624 LPG

Страница 1 PDF

Страница 2

Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this. We hope you enjoy years of problem-free operation with the product.

Страница 2 PDF

Страница 3

Contents 1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.2.1 The Benchmark Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.2.2 Benchmark Commissioning Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.3 Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.3.1 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 1.3.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.3.3 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.2 Additional documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.3.1 Symbols used in the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.4 Abbreviations/glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3.1 Homologations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3.1.1 Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 3.2.1 Technical information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 3.2.2 Dimensions and connections/clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4 Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 4.2 Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.2.1 In operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.3 Control panel description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.3.1 Description of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.4 Accessories and options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4.4.1 Optional accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 5.1 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 5.1.1 Operation checking procedure & basic fault identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 5.2 Use of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5.2.1 Using the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5.3 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5.4 Frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 6.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 6.2 Maintenance instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 6.2.1 Re-pressurising the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 6.3 Venting the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 6.4 Draining the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 7.1 Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7.1.1 List of error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 7.2 Fault finding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 8 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 8.1 Decommissioning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 9 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 9.1 Disposal and recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 10 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 10.1 Energy saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 10.2 Room thermostats and settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 11 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Contents 3

Страница 3 PDF

Страница 4

11.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 11.2 Standard warranty terms and conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 12 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 12.1 Product fiche - Boiler space heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 12.2 Package fiche - boilers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Contents 4

Страница 4 PDF

Страница 5

1 Safety 1.1 General safety instructions Danger This boiler can be used by children aged 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge when they have been given supervision or instruction concerning the safe use of the device and understand the resulting risks. Children must not be allowed to play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision. Danger If you smell gas: 1. Turn off the gas supply at the meter. 2. Open windows and doors in the hazardous area. 3. Do not operate light switches. 4. Do not operate any electrical equipment. 5. Do not use a telephone in the hazardous area. 6. Extinguish any naked flame and do not smoke. 7. Warn any other occupants and vacate the premises. 8. Telephone the National Gas Emergency Service on:- 0800 111 999. Important If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves by turning their taps through 90° (1/4 turn) downwards. A ON B OFF For advice please contact your Installer, Annual Service Provider or Baxi Customer Support - The Service Division of Baxi. You can contact Baxi Customer Support on telephone number 0344 871 1545. When contacting Baxi Customer Support it will be useful to have the "Benchmark Checklist " at the back of the Installation & Service Manual to hand as it includes details relevant to the boiler and installation. Warning Do not touch flue/chimney pipes. Depending on the settings of the appliance, the temperature of flue/chimney pipes may exceed 60 °C. Do not touch radiators for long periods. Depending on the settings of the appliance, the temperature of radiators may reach 85 °C. Take precautions with domestic hot water. Depending on the settings of the appliance, domestic hot water temperature may reach 65 °C. Caution Do not neglect to service the appliance. Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance. Fig.1 Taps ON and OFF PN-0000367 A B 1 Safety 5

Страница 5 PDF

Страница 6

1.2 Recommendations Caution Only qualified professionals are authorised to work on the boiler and the installation. The appliance has an integral frost protection mode as long as there is power to the boiler. Important Regularly check the water pressure in the system (recommended pressure is 1.5 bar). Keep the appliance accessible at all times. Do not remove or cover the user information and serial number labels affixed to the boiler control flap. They must remain legible throughout the lifetime of the boiler. 1.2.1 The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk 1.2.2 Benchmark Commissioning Checklist Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). All installations must be notified, by the installer, to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist. This product should be serviced annually to optimise its safety, efficiency and performance. The service engineer should complete the relevant section of the Benchmark Service Record in the Installation & Service manual after each service. The completed Benchmark Checklist & proof of annual servicing (where applicable) will be required in the event of any warranty work. 1.3 Liabilities 1.3.1 User's liability To guarantee optimum operation of the system, you must abide by the following instructions: Read and follow the instructions given in the manuals provided with the appliance. Call on a qualified professional to carry out installation and initial commissioning. Get your installer to explain your installation to you. Have the required inspections and maintenance carried out by a qualified installer. Keep the instruction manuals in good condition close to the appliance. 1 Safety 6

Страница 6 PDF

Страница 7

1.3.2 Installer's liability The installer is responsible for the installation and initial commissioning of the appliance. The installer must observe the following instructions: Read and follow the instructions given in the manuals provided with the appliance. Install the appliance in compliance with prevailing legislation and standards. Carry out initial commissioning and any checks necessary. Explain the installation to the user. If maintenance is necessary, warn the user of the obligation to check the appliance and keep it in good working order. Give all the instruction manuals to the user. 1.3.3 Manufacturer's liability Our products are manufactured in compliance with the requirements of all applicable Directives and Regulations. They are therefore delivered with the marking and any documents necessary. In the interests of the quality of our products, we strive constantly to improve them. We therefore reserve the right to modify the specifications given in this document. Our liability as manufacturer may not be invoked in the following cases: Failure to abide by the instructions on installing the appliance. Failure to abide by the instructions on using the appliance. Faulty or insufficient maintenance of the appliance. 1 Safety 7

Страница 7 PDF

Страница 8

2 About this manual 2.1 General Warning Installation, repair and maintenance must only be carried out only by a competent person. All Gas Safe registered engineers carry an ID card with their licence number and a photograph. You can check your engineer is registered by telephoning 0800 408 5500 or online at www.gassaferegister.co.uk This manual is intended for the user of the Potterton Assure System boiler. If the appliance is sold or transferred, or if the owner moves leaving the appliance behind you should ensure that the manual is kept with the appliance for consultation by the new owner and their installer. The appliance is designed as a boiler for use in residential domestic environments on a governed meter supply only. The selection of this boiler is entirely at the owner’s risk. If the appliance is used for purposes other than or in excess of these specifications, the manufacturer will not accept any liability for resulting loss, damage or injury. The manufacturer will not accept any liability whatsoever for loss, damage or injury arising as a result of failure to observe the instructions for use, maintenance and installation of the appliance. 2.2 Additional documentation Various timers, external controls, etc. are available as optional extras. Full details are contained in the relevant sales literature. 2.3 Symbols used 2.3.1 Symbols used in the manual This manual uses various danger levels to draw attention to special instructions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance. Danger Risk of dangerous situations that may result in serious personal injury. Danger of electric shock Risk of electric shock. Warning Risk of dangerous situations that may result in minor personal injury. Caution Risk of material damage. Important Please note: important information. See Reference to other manuals or pages in this manual. 2.4 Abbreviations/glossary CH Central heating 2 About this manual 8

Страница 8 PDF

Страница 9

DHW Domestic hot water PCU PCB for managing burner operation Pnc Condensing output SU Safety PCB 2 About this manual 9

Страница 9 PDF

Страница 10

3 Technical specifications 3.1 Homologations 3.1.1 Certifications Tab.1 Certifications CE certificate number 0085CS0215 NOx class 6 Boiler type C13, C33 3.2 Technical data 3.2.1 Technical information Tab.2 General Baxi System 15 18 Gas council numbers 41 470 56 41 470 57 Tab.3 Central heating circuit specifications BaxiSystem All models Maximum pressure bar 3 Minimum pressure bar 0.5 Central heating temperature adjustment °C 25/80 ± 5° Tab.4 Electrical specifications Baxi System All models Nominal electrical power supply voltage V 230 Nominal electrical power supply frequency Hz 50 Nominal power consumption when firing W 100 External fuse rating Amp 3 Tab.5 Other specifications Baxi System All models Degree of protection against humidity (EN 60529) IP IPX5D Boiler lift weight (dry) kg 28.1 Dimensions (height/width/depth) mm H 700/W 390/D 285 Clearances (above/below casing) front (for servicing)/(in operation) side (left hand/right hand) mm mm mm 178 / 200 450 / 5 5 / 5 These are MINIMUM recommended dimensions. Greater clearance will aid installation and maintenance. Important All data in this section are nominal values and subject to normal production tolerances. 3 Technical specifications 10 Gas council numbers (LPG models) 24 41 470 59 41 470 64 n/a n/a

Страница 10 PDF

Страница 11

3.2.2 Dimensions and connections/clearances Fig.2 Dimensions and connections / clearances 1 2 3 4 5 6 7 PN-0000624 9 10 The clearances shown in the diagram are minimum requirements to allow for case removal, spanner access and air movement. These should be observed at all times and kept clear of obstructions. 1 Condensate trap sump 2 Condensate drain 3 Heating circuit water flow 4 Gas inlet 5 Pressure relief pipe 6 Heating circuit water return 7 Pump drain point 9 Cable entry points 10 Boiler drain point on flow isolation tap 3 Technical specifications 11 700 285 390 5 5 178 200 450 5

Страница 11 PDF

Страница 12

4 Description of the product 4.1 General description The Potterton Assure System range of fully automatic gas fired wall hung condensing combination boilers are room sealed and fan assisted, and will serve central heating and mains fed domestic hot water. A Information label Tab.6 The boiler is set to give a maximum output of :- 15 model 15 kW 16.2 kW CH Pnc (Condensing) 18 model 18 kW 19.4 kW CH Pnc (Condensing) The boiler is factory set for use only on Natural Gas (G20) or LPG (G31). The boiler model, serial number and Gas Council number are also shown on the information label. This is for user reference. 4.2 Operating principle 4.2.1 In operation Whilst the boiler is in operation cooled flue gases are discharged through the flue gas discharge pipe. This may appear as a cloud of steam which is normal. Condensed water is discharged from the boiler heat exchanger into a pipe (the condensate drain). This pipe must never be altered or re-routed except by a qualified professional. 4.3 Control panel description 4.3.1 Description of the control panel 1 Display 2 Reset button 3 Central heating temperature control 4 Service diagnostic port 5 System water pressure gauge Fig.3 PN-0000368 Fig.4 Control panel PN-0000335 4 Description of the product 12 24 model 24 kW 25.8 kW CH Pnc (Condensing) 24 LPG model 24 kW 25.8 kW CH Pnc (Condensing) Information label A R Reset bar 0 1 2 3 4 1 2 3 4 5 M i n M a x

Страница 12 PDF

Страница 13

Display description The following symbols may be seen on the display OFF (frost protection still enabled) Indicates errors that prevent the burner from starting Error — not resettable by user Water pressure too low R Indicates a resettable error Not applicable Not applicable Generic error Burner lit Heating mode Units for temperature Units for pressure 4.4 Accessories and options 4.4.1 Optional accessories The table shows the accessories available for this boiler range. Tab.7 Optional accessories Part number Accessory 7211473 EP2 programmer 7212443 Twin channel timer wired 720971601 Wired room thermostat 720648301 Multifit condensate & PRV combined pump 720644401 Multifit 1m condensate drain pipe 'trace heating' element 720664101 Multifit 2m Condensate drain pipe 'trace heating' element 720664201 Multifit 3m condensate drain pipe 'trace Heating' element 720664401 Multifit 5m condensate drain pipe 'trace heating' element 5121379 Multifit remote secondary PRV kit 7683087 Multifit wired outdoor sensor (System version) For flue accessories (elbows, extensions, clamps etc.) refer to the Flue Accessories Fitting Guide supplied in the literature pack. Any of the above MUST be fitted ONLY by a qualified competent person. Further details can be found in the relevant sales literature and at www.baxi.co.uk Fig.5 Display screen R PN-0000337 4 Description of the product 13

Страница 13 PDF

Страница 14

5 Operation 5.1 Start-up 5.1.1 Operation checking procedure & basic fault identification Fig.6 Start-up and checking START Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). If the property has a prepayment meter ensure it has sufficient credit. NO If no gas, consult your supplier. Is there electricity to the boiler ? Is the display lit ? Check electrical supply to boiler is switched on. NO YES Is the Burner Flame showing. Burner Flame (Indicates burner is on) Boiler operating satisfactorily. NO YES YES YES Is the E and R symbol illuminated or flashing ? YES Press the Reset Button (e.g. press and hold for 5 seconds) If it does not reset CONTACT YOUR INSTALLER OR SERVICE ENGINEER. Reset Symbol Is the Spanner symbol illuminated or flashing ? YES Spanner Symbol Error Code Flame Failure OR PN-0000391 R R R R Boiler Temperature Error Symbol Central Heating Reset Button 5 Operation 14 R Reset bar 0 1 2 3 4 M i n M a x

Страница 14 PDF

Страница 15

Fig.7 Start-up and checking (continued) IMPORTANT: Where Low Flow Taps or Fittings are intended to be used in the DHW system connected it is strongly recommended that the DHW flow rate DOES NOT fall below 2.5 l/min. This will ensure reliable operation of the DHW function. Is the Timer ON and calling for heat ? Is the Room Thermostat (if fitted) set high enough ? 12 1 2 3 4 5 6 7 8 9 10 11 Typical examples of external timer Ensure timer is set for Central Heating ON (see any instructions supplied with timer) NO YES YES NO 15 10 5 20 25 15 10 5 20 25 Turn Room Thermostat to maximum setting (typical example shown) CH ON CH OFF bar 0 1 2 3 4 Is the Central Heating System Pressure between 1.0 and 2.5 bar ? If the reading falls below 1.0 bar repressurise the system as described in Maintenance NO Error Code 118 showing low pressure. YES If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible PN-0000634 5 Operation 15

Страница 15 PDF

Страница 16

5.2 Use of the control panel 5.2.1 Using the control panel Important OpenTherm controller.Your installer will advise you when this type of control is connected to the boiler. If so, any change to the boiler settings (e.g. heating temperature) must be made using the OpenTherm controller not the boiler control panel. Please consult the user manual for the OpenTherm controller. To increase or decrease the boiler temperature: 1. Turn the control knob with the symbol over it clockwise to increase the boiler set temperature. The set temperature will be shown on the display screen. 2. Turn the control knob with the symbol over it anticlockwise to decrease the boiler temperature. The temperature will be shown on the display screen. To reset the boiler: 1. Press the Reset button for approximately 1 second, holding the button for more than 2 seconds the boiler will not reset. (see List of error codes, page 21.) 5.3 Shutdown Isolate the mains power supply at the fused spur unit. Isolate the gas supply at the boiler valve. Protect the boiler from frost. Important The boiler is not protected against frost once it has been shut down. Important If it is anticipated that the boiler will not be used for a long period or the property is to be unoccupied, it is advised to drain the system if the electricity and gas supplies are to be turned off. Your installer will be able to offer advice. 5.4 Frost protection Where possible, draining the system should be avoided. If the system is to be unused during winter months several precautions must be taken: Any parts of the system that are in unheated areas of the dwelling should be fitted with a device such as a pipe thermostat or frost thermostat. Power must remain supplied to the boiler and controls. Gas must remain supplied to the boiler. The boiler pump will operate if the system temperature drops below 7°C. If the temperature falls to 4°C the burner will ignite and remain lit until the temperature reaches 10°C. At this temperature the burner will extinguish but the pump will continue to operate for 15 minutes. This feature will protect the boiler and to some extent adjacent parts of the system but additional devices must be incorporated to guarantee frost protection. Fig.8 Using the control panel PN-0000372 R 5 Operation 16 R Reset bar 0 1 2 3 4 M i n M a x

Страница 16 PDF

Страница 17

6 Maintenance 6.1 General The boiler must be serviced annually in accordance with the Installation and Service Manual and the relevant section of the Benchmark Service Record completed in order to maintain the warranty. Important Taking out a maintenance contract is recommended. Caution Maintenance operations must be performed by a qualified competent person. Use only Potterton genuine spare parts. The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 6.2 Maintenance instructions The central heating system should be checked regularly. Proceed as follows: 1. Check the water pressure in the central heating system. Important If the water pressure is lower than 0.7 bar, the system must be topped up. See Re-pressurising the system. Important If the water pressure drops below 0.5 bar the boiler will not work. 2. Check radiators for leaks and (especially in damp areas) for rust. 3. Open and close the radiator valves several times a year to ensure they can still be rotated. Caution Only a qualified installer may clean the inside of the boiler. 6.2.1 Re-pressurising the system If the water pressure is too low, the system must be re-pressurised. The normal operating water pressure is between 1 and 2 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Ensure that the filling loop is disconnected if it is of a temporary type. Contact your installer. 6 Maintenance 17

Страница 17 PDF

Страница 18

It may be necessary to repressurise the system occasionally (when the water pressure falls below 0.7). A filling device (the filling loop) will be fitted on the system. This may be on the boiler itself, or on pipework near to the boiler. Important If the water pressure requires regular re-pressurising a fault or leak is indicated. Seek advice from your installer. Depending on which filling loop is fitted, a temporary filling loop consists of two isolating taps and a separate filling pipe with connection fittings. Only when repressurising should the filling pipe be connected between the two taps. Ensure that the nuts on the pipe ends are tightened onto the taps. 1. Fully open one of the taps first, and then while watching the pressure gauge, carefully open the second tap. Important The system pressure is shown at all times on the pressure gauge and can be viewed on the display when there is power to the boiler. 2. When the figures on the display or needle on the pressure gauge indicate between 1 and 1.5 bar turn both taps off. 3. Disconnect the filling pipe from the taps (a small amount of water may be present) and remove it. Keep the pipe in a safe place for future use. 4. If blanking caps are available fit them to the taps. See Go to the "How to videos" section of the "Information & advice" page at www.baxi.co.uk for further details. 5. When the correct pressure is restored the boiler will reset automatically. Fig.9 Water pressure PN-0000641 6 Maintenance 18

Страница 18 PDF

Страница 19

6.3 Venting the installation If any air is present in the appliance or system it must be removed in order to prevent nuisance noises that may occur during heating or when drawing off hot water. Proceed as follows: 1. Open the valves of all the radiators connected to the system. 2. Set the room thermostat to the highest possible temperature and any timers to ‘ON’. 3. Wait until the radiators are warm. 4. Switch off the boiler. 5. Vent the radiators. Work from the lowest radiator in the property. 6. Open the bleed vent with the key, keeping a cloth pressed against the vent. 7. Wait until water comes out of the bleed vent and then close. Warning The CH water in the radiators will still be hot. 8. Switch the boiler on. 9. After venting, check that the water pressure in the system is still adequate. Important If the water pressure is lower than 0.7 bar, the water must be topped up. If necessary repressurise the system (recommended pressure between 1 and 1.5 bar when cold). 10. Reset the room thermostat to the desired temperature. The purpose of the function is to remove as much air as possible from the heating system. 1. Turn off the power to the boiler and rotate the CH control knob fully anticlockwise. 2. Turn on the power to the boiler. The display shows "000" . 3. Turn the CH control knob ( ) 1/4 turn clockwise twice in quick succession (within 2 seconds). 4. Display shows "312" while de-aeration is taking place (approximately 7 minutes). 5. When de-aeration has completed, the display will show the primary flow temperature and the CH ( ) symbols. Fig.10 Venting the radiators 7 6 A C B 5 4 3 2 1 2 3 4 1 10 PN-0000468 Fig.11 Enabling de-aeration function M a x M i n R M a x M i n R x 2 PN-0000392 6 Maintenance 19 R Reset bar 0 1 2 3 4 M i n M a x

Страница 19 PDF

Страница 20

Caution If the system is drained (even partly, when replacing a radiator for example) the de-aeration function must be repeated. Also the inhibitor concentration must be checked and replenished if necessary. 6.4 Draining the installation It may be necessary to drain the central heating system if radiators need to be replaced, if there is a major water leak or if there is a risk of freezing. Proceed as follows: 1. Open the valves of all the radiators connected to the system. 2. Switch off the boiler's electrical connection. 3. Wait approximately ten minutes, until the radiators feel cold. 4. Connect a drain hose to the lowest draining point. Place the end of the hose in a drain or at a place where drained pipe water will not cause any damage. 5. Open the central heating system fill/drain valve. Drain the installation. Warning The water may still be hot. 6. Close the drain valve when no more water comes from the draining point. Important After draining the system, the concentration of corrosion inhibitor and antifreeze agent may be extremely diluted - check with your installer. Fig.12 Draining the installation AD-3000730-01 5 3 2 1 2 3 4 1 4 6 Maintenance 20

Страница 20 PDF

Страница 21

7 Troubleshooting 7.1 Error codes 7.1.1 List of error codes Tab.8 Table of error codes Error code Description of fault 09 Gas valve connection cable 15 Gas valve fault 20 Central heating NTC fault 28 Flue NTC fault 40 Central heating return NTC fault 83 Communication error 109 Pre-circulation fault 110 Safety thermostat operated 118 Primary system water pressure too low 125 Circulation fault (primary) 128 Flame failure 130 Flue NTC operated 133 Interruption of gas supply or flame failure 135 Interruption of gas supply (internal error) 154 Flow / return sensor temperature test 160 Fan or fan wiring fault 270 Circulation fault (Dry fire) 321 Hot water NTC fault 384 False flame The display shows two types of signals: and R . In both cases the display shows symbol and the numeric value of the error (see the table of error codes above). The spanner symbol appears it cannot be reset by the user. Please contact your Installer, Annual Service Provider or Baxi Customer Support. You can contact Baxi Customer Support on 0344 871 1545. R fault errors can be reset by pressing the Reset button. For 103, 104, 107 & "Bat" please contact your installer, annual service provider or Baxi Customer Support Important If a different error code from those described in the "Table of error codes" appears on the display contact Baxi Customer Support. Fig.13 Control panel error display PN-0000393 R 7 Troubleshooting 21 R Reset bar 0 1 2 3 4 M i n M a x

Страница 21 PDF

Страница 22

7.2 Fault finding Tab.9 Problems and solutions Problem Possible causes Solution The radiators are cold. The temperature set point for the heating is too low. Increase the value with the CH temperature knob or if a room thermostat is connected, increase the temperature on the room thermostat. The heating mode is deactivated. Activate the heating mode. The radiator valves are not open. Open the valves of all radiators connected to the system. The boiler is not working. Check that the boiler is being supplied with power. Check fuses and switches. Check whether the gas isolation cock is properly open. If the property has a prepayment meter ensure it has sufficient credit. The water pressure is too low (< 0.5 bar). Re-pressurise the system. The boiler is not working. The temperature set point for the heating is too low. Increase the value with the CH temperature knob or if a room thermostat is connected, increase the temperature on the room thermostat. No demand for heating. Ensure that timers & thermostats are calling for heat. No power supply. Check that the boiler is being supplied with power. Check the fuses and switches. The water pressure is too low (< 0.5 bar). Re-pressurise the system. The boiler is indicating an error. Press the Reset button. Correct the error, if possible. The gas pressure is too low. Check whether the gas isolation cock is fully open. Open the gas isolation cock. Condensate drain blocked. Check drain, especially any external runs in freez­ ing temperatures. If the boiler is not working also check section "Operation checking procedure and basic fault identification" or contact your Installer. 7 Troubleshooting 22

Страница 22 PDF

Страница 23

8 Decommissioning 8.1 Decommissioning procedure Caution Only qualified persons are authorised to work on the appliance and system to decommission. If your boiler needs to be decommissioned either temporarily or permanently the following should be performed: 1. Switch off the boiler’s electrical connection. 2. Close the gas isolation tap. 3. Drain the central heating system. Seek the advice of your installer. 8 Decommissioning 23

Страница 23 PDF

Страница 24

9 Disposal 9.1 Disposal and recycling Caution Removal and disposal of the boiler must be carried out by a qualified person in accordance with local and national regulations. 9 Disposal 24

Страница 24 PDF

Страница 25

10 Environmental 10.1 Energy saving Tips on saving energy: Do not cover radiators. Do not hang curtains in front of radiators. Install reflective panels behind the radiators to prevent heat loss. Insulate the pipes in rooms that are not heated (cellars and lofts). Install loft insulation & double glazing. Use draught excluders where necessary. Upgrade any older boiler external controls. Turn down room thermostats by 1°. Turn off radiators in rooms not in use. Do not run hot (or cold) water pointlessly. Fit a water-saving shower head to save up to 40 % energy. Take showers rather than baths. A bath consumes twice as much water and energy. 10.2 Room thermostats and settings Various models of room thermostat are available. The thermostat type and setting affect the total energy consumption. A few tips: A modulating thermostat in combination with thermostatic radiator valves saves energy and offers considerable comfort. This combination gives you flexibility with the temperatures. Do not fit thermostatic radiator valves in the room in which the room thermostat is installed. Completely closing and opening thermostatic valve radiators causes undesirable temperature fluctuations. Open and close thermostatic valves in small steps. Lower the thermostat to around 20°C. This reduces heating costs and energy consumption. Lower the room thermostat temperature temporarily if opening windows to air the rooms. If you are using an ON/OFF type thermostat, reduce the water temperature value in summer (e.g. 60°C in summer and 80°C in winter). When setting an hourly programmable thermostat, consider days when you are absent or on holiday. Electricity production and energy savings reach their optimum level with a programmed and activated timer programme. 10 Environmental 25

Страница 25 PDF

Страница 26

11 Warranty 11.1 General To make sure your boiler warranty is activated and maintained, it is essential that the: 1. Benchmark checklist is completed by your installer 2. Warranty is registered within 30 days 3. Boiler has an annual service Important Please note that failure to adhere to terms and conditions will invalidate your warranty. 11.2 Standard warranty terms and conditions Warranty registration, service & repair For full terms and conditions, visit www.baxi.co.uk/terms. Benchmark checklist The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly. It can be found at the back of the installation and service manual and should be kept in a safe place for the life of the boiler. We will check that the Benchmark Checklist has been completed on an in-warranty visit. Ways to register your warranty If your boiler is eligible for an extended warranty, your installer may register the product on your behalf and provide you with the relevant documentation. Please check with your installer. Should this not be the case, you can register your warranty online at www.baxi.co.uk/registration Annual service A service must be completed every 12 months from the date of installation to maintain your warranty. This service must be completed by one of the following: A Gas Safe registered installer/engineer Baxi Customer Support; call us 0344 871 1545 Please make sure that your engineer has logged the service information at the back of the installation and service manual. You will be asked for your service history on any in-warranty repair visit. If you experience a problem with your boiler For any in or out of warranty repair, Baxi Customer Support is on hand to help you. Call our award-winning team to arrange for one of our nationwide team of Gas Safe registered engineers to visit. If your product is in warranty, everything is free of charge, subject to our warranty terms and conditions. If it is out of warranty, we can still help and offer a range of options you can choose from to suit your needs. Contact Baxi Customer Support 0344 871 1545 Opening hours Monday - Friday, 8.00am - 6.00pm Weekends and Bank Holidays, 8.30am - 2.00pm Please note calls may be recorded for training and monitoring purposes. When contacting Baxi Customer Support, please have the following information to hand: Boiler serial number. 11 Warranty 26

Страница 26 PDF

Страница 27

Proof of purchase if you do not have the boiler serial number Please note that for in-warranty repairs, our engineers will ask to see your service history record, completed Benchmark Checklist and details of your installer. These can all be found in the Installation and Service manual. 11 Warranty 27

Страница 27 PDF

Страница 28

12 Appendix 12.1 Product fiche - Boiler space heaters Tab.10 Product fiche for boiler space heaters Baxi System 15 18 Seasonal space heating energy efficiency class Rated heat output (Prated or Psup) kW 15 18 Seasonal space heating energy efficiency % 93 Annual energy consumption GJ 46 Sound power level LWA indoors dB 46 See For specific precautions about assembling, installing and maintaining: Safety, page 5 12 Appendix 28 24 A 24 A A 24 LPG A 24 93 56 48 93 74 51 93 74 51

Страница 28 PDF

Страница 29

12.2 Package fiche - boilers Fig.14 Package fiche for boilers indicating the space heating energy efficiency of the package AD-3000743-01 % 1 ‘I’ 2 % + 3 % ( - ‘I’ ) x 0.1 = ± 4 % (‘III’ x + ‘IV’ x ) x 0.9 x ( /100) x = + (1) A* = 0.95, A = 0.91, B = 0.86, C = 0.83, D - G = 0.81 5 % ( - ‘I’ ) x ‘II’ = + 6 % 0.5 x 0.5 x = - 5 4 <30% G F E D C B A A + A ++ A +++ % + (50 x ‘II’) = 7 7 % from fi che of solar device Solar contribution AND Supplementary heat pump Solar contribution The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. Boiler and supplementary heat pump installed with low temperature heat emitters at 35°C ? Seasonal space heating energy effi ciency class of package Seasonal space heating energy effi ciency of package OR Seasonal space heating energy effi ciency (in %) Supplementary heat pump Tank rating Collector effi ciency (in %) Tank volume (in m³) Collector size (in m²) Seasonal space heating energy effi ciency (in %) Supplementary boiler Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, Class VII = 3.5%, Class VIII = 5% Temperature control Seasonal space heating energy effi ciency of boiler (1) If tank rating is above A, use 0.95 select smaller value from fi che of heat pump from fi che of heat pump from fi che of boiler from fi che of temperature control 12 Appendix 29

Страница 29 PDF

Страница 30

I The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. II The factor for weighting the heat output of preferential and supplementary heaters of a package as set out in the following table. III The value of the mathematical expression: 294/(11 · Prated), whereby ‘Prated’ is related to the preferential space heater. IV The value of the mathematical expression 115/(11 · Prated), whereby ‘Prated’ is related to the preferential space heater. Tab.11 Weighting of boilers Psup / (Prated + Psup)(1)(2) II, package without hot water storage tank II, package with hot water storage tank 0 0 0 0.1 0.3 0.37 0.2 0.55 0.70 0.3 0.75 0.85 0.4 0.85 0.94 0.5 0.95 0.98 0.6 0.98 1.00 ≥ 0.7 1.00 1.00 (1) The intermediate values are calculated by linear interpolation between the two adjacent values. (2) Prated is related to the preferential space heater or combination heater. Tab.12 Package efficiency Baxi System 15 18 Temperature control X % Temperature control Y % 12 Appendix 30 24 24 LPG

Страница 30 PDF

Страница 31

© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations.

Страница 31 PDF

Страница 32

Baxi Customer Support 0344 871 1545 Opening hours Monday - Friday, 8.00am-6.00pm Weekends and Bank Holidays, 8.30am-2.00pm Please note calls may be recorded for training and monitoring purposes baxi.co.uk Register now to activate your warranty: www.baxi.co.uk/registration For the warranty to be maintained, please make sure... Benchmark checklist is completed Warranty is registered within 30 days The boiler has an annual service 1 2 3 For full terms and conditions, visit www.baxi.co.uk/terms. Failure to adhere to terms and conditions will void your manufacturer’s warranty. Baxi Brooks House, Coventry Road, Warwick, CV34 4LL Please ensure the boiler is installed in accordance with these installation instructions and that you adhere to the Building Regulations. e&oe All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. 7686962-01