Страница 1

User Guide Condensing Combination Boiler 124 - 128 Combi en United Kingdom Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Страница 1 PDF

Страница 2

2 © Baxi Heating UK Ltd 2017 © Baxi Heating UK Ltd 2017 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988. Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick. CV34 4LL Full acknowledgement of author and source must be given. WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. 1.0 Quick Reference Guide 3 2.0 Troubleshooting 4 3.0 Temperature Adjustment & Care of the Boiler 6 4.0 Repressurising System & ‘Service Due’ 7 5.0 Clearances 8 6.0 Error Codes 9 7.0 Legislation 10 8.0 Warranty & Service 11 9.0 ErP Information 13 10.0 Emergency 17 11.0 Disposal 17 Section Page Contents Boiler Controls - see opposite page for Operating Quick Reference Guide (Fascia Cover removed for clarity) 0086 ISO 9001 FM 00866 The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk Model Range Baxi 124 Combi G.C.No 47-077-25 Baxi 128 Combi G.C.No 47-077-26 This boiler can be used by children aged 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge when they have been given supervision or instruction concerning the safe use of the device and understand the resulting risks. Children must not be allowed to play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision. Warning !

Страница 2 PDF

Страница 3

1.0 Quick Reference Guide 3 © Baxi Heating UK Ltd 2017 R R Domestic Hot Water and Central Heating OFF (frost protection still enabled) Indicates errors that prevent burner from starting Error - Not resettable by user Water pressure too low Indicates a resettable error Indicates navigation in programming mode (parameter) Indicates navigation in programming mode Generic error Burner lit DHW request Heating mode Units for temperature Units for pressure Service due (when activated) Display Description Central Heating Temperature Adjustment Boiler Information View Standby - Reset - Esc R Standby - Reset - Esc Boiler Information View Increase Central Heating Temperature Button * Decrease Central Heating Temperature Button * * Important Note: If your control system is fitted with the Optional Outdoor Sensor, these buttons will affect it’s operation. Please consult your installer for advice. Increase Domestic Hot Water Temperature Button Decrease Domestic Hot Water Temperature Button Summer / Winter / Only Heating Mode Button Key to Controls Display showing all available segment Summer - Winter - Only Heating Mode Domestic Hot Water Temperature Adjustment Summer - Domestic Hot Water only request mode Winter - Domestic Hot Water & Central Heating request mode Only Heating - Only Central Heating request mode NOTE: When altering any settings it is necessary that the buttons are FIRMLY pressed for several seconds. R

Страница 3 PDF

Страница 4

2.0 Troubleshooting 4 © Baxi Heating UK Ltd 2017 Boiler not working START Make sure the gas supply is turned ON and check if other gas appliances are operating (e.g. fire, cooker). NO If no gas, consult your supplier. Is there electricity to the boiler ? Is the display lit ? R Check electrical supply to boiler is switched on. NO YES Is the Burner Flame symbol showing ? R Burner Flame (Indicates burner is on) Boiler operating satisfactorily. NO YES YES YES Is the E and R symbol illuminated or flashing ? R YES Press the Reset Button Error Symbol If it does not reset CONTACT YOUR INSTALLER OR SERVICE ENGINEER. R Reset Symbol Is the Spanner symbol illuminated or flashing ? YES Spanner Symbol Boiler Temperature Central Heating Error Code Flame Failure OR Reset Button

Страница 4 PDF

Страница 5

2.0 Troubleshooting 5 © Baxi Heating UK Ltd 2017 Is the Timer ON and calling for heat ? Is the Room Thermostat (if fitted) set high enough ? 12 1 2 3 4 5 6 7 8 9 10 11 Typical examples of external timer Ensure timer is set for Central Heating ON (see any instructions supplied with timer) NO YES YES NO 15 10 5 20 25 15 10 5 20 25 Turn Room Thermostat to maximum setting (typical example shown) If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible CH ON CH OFF bar 0 1 2 3 4 Is the Central Heating System Pressure between 1 and 2.5 bar ? If the reading* falls below 1 bar repressurise the system as described in section 4.1. NO R Error Code 118 showing low pressure. YES *To display the water pressure press 6 times. ‘05’ will alternate with the system pressure. (NOTE: When the pump is running the gauge under the boiler may show a slightly different reading to the display)

Страница 5 PDF

Страница 6

3.0 Temperature Adjustment & Care of the Boiler 6 © Baxi Heating UK Ltd 2017 R 3.1 To increase or decrease the boiler temperature 1. Press to increase the Central Heating temperature. 2. Press to decrease the Central Heating temperature. NOTE: An overheat thermostat (NTC) is positioned in the heat exchanger which shuts down the appliance if the boiler temperature exceeds 100°C. Press button to re- establish normal operating conditions. 3.2 To increase or decrease the domestic hot water temperature 1. Press to increase the Domestic Hot Water temperature. 2. Press to decrease the Domestic Hot Water temperature. 3.3 Summer - Winter - Only Heating Mode 1. Press button until the required mode appears:- 2. See 3.1 or 3.2 to set the required temperature. 3.4 Cleaning the Outer Case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 3.5 Boiler Frost Protection 1. The boiler incorporates an integral frost protection feature that will operate in both Central Heating & Domestic Hot Water modes, and also when in standby ( displayed). 2. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised. 3. Further protection may be required for the system. Consult your installer for details. 3.6 Information Display 1. The table opposite shows information that can be displayed by pressing the button. 2. Press to return to the normal display. Central Heating Temperature Adjustment R Display Screen Domestic Hot Water Temperature Adjustment R Summer - Domestic Hot Water only request mode Winter - Domestic Hot Water & Central Heating request mode Only Heating - Only Central Heating request mode Summer - Winter - Only Heating Mode The button can be pressed so that the display shows the following information:- 1 press - ‘00’ alternates with Sub-Code (only when fault on boiler) or ‘000’ 2 presses - ‘01’ alternates with CH Flow Temperature 3 presses - ‘02’ alternates with Outside Temperature (where Sensor fitted) 4 presses - ‘03’ alternates with DHW Temperature 5 presses - ‘04’ alternates with DHW Temperature 6 presses - ‘05’ alternates with System Water Pressure 7 presses - ‘06’ alternates with CH Return Temperature 8 presses - ‘07’ alternates with Flue Temperature 9 presses - ‘08’ alternates with Heat Exchanger Temperature R

Страница 6 PDF

Страница 7

7 © Baxi Heating UK Ltd 2017 bar 0 1 2 3 4 bar 0 1 2 3 4 Normal Pressure Requires Repressurising Pressure Gauge Front and Side Panel removed for clarity View Under Appliance R ‘Service Due’ Message When activated ‘Sd’ will show for three seconds, alternating with the boiler temperature. Fig. 1 Fig. 2 4.0 Repressurising System & ‘Service Due’ 4.1 Central Heating System Pressure 1. The water pressure in the central heating system is indicated by the pressure gauge and also can be viewed on the display when there is power to the boiler. 2. To display the water pressure press 6 times. ‘05’ will alternate with the system pressure. (NOTE: When the pump is running the gauge under the boiler may show a slightly different reading to the display) . 3. With the system cold and the boiler not operating the pressure should be at least 0.5 bar. During operation the pressure should not exceed 2.5 bar, and will normally be between 1.0 and 1.5 (Fig. 1). 4. A pressure of 3 or greater indicates a fault (E117 displayed). The safety pressure relief valve will operate, at a pressure of 3 (Fig. 3). It is important that your Installer or Service Engineer is contacted as soon as possible. 5. The minimum pressure for correct operation is 0.5. If the pressure falls below 0.5, this may indicate a leak on the central heating system (Fig. 2). Error Code E118 will be shown on the display. 4.2 To Re-Pressurise the System (Using Temporary Filling Loop) 1. It may be necessary to repressurise the system occasionally (when the water pressure falls below 0.7 bar). A filling device (filling loop) will be fitted on the system. This may be on the boiler itself or on pipework near to the boiler. Seek advice from your installer. 2. If the water pressure requires regular re-pressurising a fault or leak is indicated (see section 4.1). Seek advice from your installer. 3. The filling loop will consist of two isolating taps and a separate temporary filling pipe with connection fittings. 4. Fit the temporary filling pipe, and tighten the two nuts on the pipe to the taps. 5. Fully open one of the taps first, and then while watching the pressure gauge, carefully open the second tap. 6. When the needle on the pressure gauge indicates between 1 and 2 bar, turn both taps off. 7. The temporary filling loop pipe must be disconnected and completely removed after the system is pressurised. (Ensure the two isolating taps are in the OFF position before disconnecting.) Keep the pipe in a safe place. 4.3 ‘Service Due’ Message (Fig. 3) 1. When activated the ‘Service Due’ message will be shown on the boiler display after 11 months operation. 2. Please contact your Installer, Annual Service Provider or Baxi Customer Support on 0344 871 1545 to arrange your Annual Service. Fig. 3

Страница 7 PDF

Страница 8

5.0 Clearances 8 © Baxi Heating UK Ltd 2017 5.1 For your Safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 2. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations. 3. Your boiler must not be operated without the casing correctly fitted. 4. Do not interfere with any sealed components on this boiler. 5. Take note of any warning labels on your boiler. 6. Your boiler should have the following minimum clearances for Safety and Maintenance (Figs. 4 & 5):- Top - 175mm Bottom - 170mm* Left side - 5mm Right Side - 5mm Front - 5mm (In Operation) - 450mm (For Servicing) *This is MINIMUM recommended dimension. Greater clearance will aid installation and maintenance. 7. If your boiler is installed in a compartment, do not use it for storage purposes. Do not obstruct any purpose provided ventilation openings. 8. Flammable materials must not be stored in close proximity to your boiler. 9. Avoid skin contact when your boiler is in operation, as some surfaces may get hot e.g. pipework. 10. Ensure that the flue terminal, outside the house, does not become damaged or obstructed, particularly by foliage. 11. It is important that the condensate drain system is not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. GB - Heating Industry definition meaning England, Scotland, Wales, Northern Ireland, Isle of Man and the Channel Isles 170mm* Min 700mm 390mm 5mm Min 5mm Min 5mm 450mm For Servicing Purposes Fig. 4 Fig. 5 In Operation At least 1.5° 300mm (290mm with flap removed) 175mm Min (300mm Min if using 80/125 flue system)

Страница 8 PDF

Страница 9

6.0 Error Codes 9 © Baxi Heating UK Ltd 2017 6.1 List of Error Codes 1. The display shows two types of signals: and . In both cases the display shows symbol and the numeric value of the error (see the “error table” below). 2. The spanner cannot be reset by the user. Please contact your Installer, Annual Service Provider or Baxi Customer Support on 0344 871 1545. 3. Fault errors can be reset by pressing the button. WARNING: If an error code (if different from the ones described below) appears on the display or a certain fault appears frequently, contact your Installer, Annual Service Provider or Baxi Customer Support on 0344 871 1545. R R R Gas Valve Connection Cable Gas Valve Fault Central Heating NTC Fault Flue NTC Fault Central Heating Return NTC Fault Calibration Required Pre-circulation Fault Safety Thermostat Operated Primary System Water Pressure Too High Primary System Water Pressure Too Low Circulation Fault (Primary) Flame Failure Flue NTC Operated Interruption Of Gas Supply or Flame Failure Elapsed Time - Gas Valve Open Without Gas Interruption Of Gas Supply (Internal Error) Flow/Return Sensor Temperature Test Fan or Fan Wiring Fault Circulation Fault (Dry Fire) Hot Water NTC Fault False Flame 09 15 20 28 40 55 109 110 117 118 125 128 130 133 134 135 154 160 270 321 384 Table Of Error Codes

Страница 9 PDF

Страница 10

10 © Baxi Heating UK Ltd 2017 7.0 Legislation 7.1 Installation, Commissioning, Service & Repair 1. This appliance must be installed in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3. Definition of competence: A person who works for a Gas Safe registered company and holding current certificates in the relevant ACS modules, is deemed competent. 4. In IE (Eire), this must be carried out by a competent person as stated in I.S. 813 “Domestic Gas Installations”. Lifting - This product should be lifted and handled by two people. Stooping should be avoided and protective equipment worn where necessary. Carrying & lifting equipment should be used as required, e.g. when installing in a loft space. All Gas Safe registered engineers carry an ID card with their licence number and a photograph. You can check your engineer is registered by telephoning 0800 408 5500 or online at www.gassaferegister.co.uk The boiler meets the requirements of Statutory Instrument “The Boiler (Efficiency) Regulations 1993 No 3083” and is deemed to meet the requirements of Directive 92/42/EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels:- The product data in Section 9.0 satisfies the requirements of EU regulations no. 811/2013 & no. 813/2013 supplementing directive 2010/30/EU Type test for purpose of Regulation 5 certified by: Notified Body 0085. Product/Production certified by: Notified Body 0086. For GB/IE only. 7.2 Benchmark Commissioning Checklist 1. Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales). 2. All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist. 3. This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each service. 4. The completed Benchmark Checklist may be required in the event of any warranty work.

Страница 10 PDF

Страница 11

11 © Baxi Heating UK Ltd 2017 8.0 Warranty & Service 8.1 General To make sure your boiler warranty is activated and maintained, it is essential that the: 1. Benchmark checklist is completed by your installer 2. Warranty is registered within 30 days 3. Boiler has an annual service Please note that failure to adhere to terms and conditions will make your warranty invalid. 8.2 Standard Warranty Terms and Conditions Warranty Registration, Service & Repair For full terms and conditions, visit www.baxi.co.uk/terms. Benchmark Checklist The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly. It can be found at the back of the installation and service manual and should be kept in a safe place for the life of the boiler. We will check that the Benchmark Checklist has been completed on an in-warranty visit. Ways to register your warranty If your boiler is eligible for an extended warranty, your installer may register the product on your behalf and provide you with the relevant documentation. Please check with your installer. Should this not be the case, you can register your warranty online at www.baxi.co.uk/registration To activate a standard two year warranty, please use one of the following methods: • Freephone 0800 013 7989 or • Return the enclosed registration card

Страница 11 PDF

Страница 12

12 © Baxi Heating UK Ltd 2017 8.0 Warranty & Service Lift Flap for access to Information Label Annual Service A service must be completed every 12 months from the date of installation to maintain your warranty. This service must be completed by one of the following: • A Gas Safe registered installer/engineer • Baxi Customer Support; call us 0344 871 1545 Please make sure that your engineer has logged the service information at the back of the installation and service manual. You will be asked for your service history on any in-warranty repair visit. If you experience a problem with your boiler For any in or out of warranty repair, Baxi Customer Support is on hand to help you. Call our award-winning team to arrange for one of our nationwide team of Gas Safe registered engineers to visit. If your product is in warranty, everything is free of charge, subject to our warranty terms and conditions. If it is out of warranty, we can still help and offer a range of options you can choose from to suit your needs. Contact Baxi Customer Support 0344 871 1545 Opening hours Monday - Friday, 8.00am - 6.00pm Weekends and Bank Holidays, 8.30am - 2.00pm Please note calls may be recorded for training and monitoring purposes. When contacting Baxi Customer Support, please have the following information to hand: • Boiler serial number. This can be found on the appliance. • Proof of purchase if you do not have the boiler serial number. Please note that for in-warranty repairs, our engineers will ask to see your service history record, completed Benchmark Checklist and details of your installer. These can all be found in the installation and user manuals.

Страница 12 PDF

Страница 13

13 © Baxi Heating UK Ltd 2017 9.0 ErP Information 9.1 Product Fiche - Combination Boilers Product fiche for combination boilers Space heating - Temperature application Baxi Combi Medium Medium Water heating - Declared load profile Seasonal space heating energy efficiency class A A Water heating energy efficiency class A A Rated heat output (Prated or Psup) kW Space heating - Annual energy consumption kWh GJ Water heating - Annual energy consumption kWh GJ Seasonal space heating energy efficiency % Water heating energy efficiency % Sound power level LWA indoors dB See For specific precautions about assembling, installing and maintaining, consult the relevant section as detailed on the Contents page. 124 128 20 24 XL XL 17222 20556 62 74 88 93 93 17 17 86 49 50

Страница 13 PDF

Страница 14

14 © Baxi Heating UK Ltd 2017 9.0 ErP Information 9.2 Package Fiche - Boilers Package fiche for boilers indicating the space heating energy efficiency of the package AD-3000743-01 % 1 ‘I’ 2 % + 3 % ( - ‘I’ ) x 0.1 = ± 4 % (‘III’ x + ‘IV’ x ) x 0.9 x ( /100) x = + (1) A* = 0.95, A = 0.91, B = 0.86, C = 0.83, D - G = 0.81 5 % ( - ‘I’ ) x ‘II’ = + 6 % 0.5 x 0.5 x = - 5 4 <30% G F E D C B A A + A ++ A +++ % + (50 x ‘II’) = 7 7 % e civ e d r alo s f o e h c fi m o rf p m u p t a e h y r a t n e m e l p p u S D N A n o it u b irt n o c r a l o S n o it u b irt n o c r a l o S d ella ts ni e c n o y c n eic fif e y g r e n e la u tc a sti o t d n o p s e rr o c t o n y a m e h c fi sih t ni r o f d e div o r p stc u d o r p f o e g a k c a p e h t f o y c n eic fif e y g r e n e e h T in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. ? C ° 5 3 t a s r e tti m e t a e h e r u t a r e p m e t w o l h ti w d e ll a t s n i p m u p t a e h y r a t n e m e l p p u s d n a r e li o B e g a k c a p f o s s a l c y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S R O ) % ni( y c n eic fif e y g r e n e g nit a e h e c a p s la n o s a e S p m u p t a e h y r a t n e m e l p p u S g nit a r k n a T ni( y c n eic fif e r o tc ello C %) )³ m ni( e m ulo v k n a T )² m ni( e zis r o tc ello C ) % ni( y c n eic fif e y g r e n e g nit a e h e c a p s la n o s a e S r e li o b y r a t n e m e l p p u S , % 5 . 1 = III s s al C , % 2 = II s s al C , % 1 = I s s al C Class IV = 2%, Class V = 3%, Class VI = 4%, Class VII = 3.5%, Class VIII = 5% l o rt n o c e r u t a r e p m e T r e li o b f o y c n e i c fi f e y g r e n e g n it a e h e c a p s l a n o s a e S 5 9 . 0 e s u , A e v o b a si g nit a r k n a t fI ) 1 ( e ula v r ella m s tc ele s p m u p t a e h f o e h c fi m o rf p m u p t a e h f o e h c fi m o rf r elio b f o e h c fi m o rf lo rt n o c e r u t a r e p m e t f o e h c fi m o rf I The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. II The factor for weighting the heat output of preferential and supple mentary heaters of a package as set out in the following table.

Страница 14 PDF

Страница 15

15 © Baxi Heating UK Ltd 2017 9.0 ErP Information 9.2 Package Fiche - Boilers (cont) Package efficiency Temperature control X Baxi Combi % Temperature control Y % The value of the mathematical expression: 294/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater. The value of the mathematical expression 115/(11 ʷ Prated), whereby ‘Prated’ is related to the preferential space heater. Weighting of boilers 0 0 0 0.1 0.3 0.37 0.2 0.55 0.70 0.3 0.75 0.85 0.4 0.85 0.94 0.5 0.95 0.98 0.6 0.98 1.00 ≥ 0.7 1.00 1.00 (1) The intermediate values are calculated by linear interpolation between the two adjacent values. (2) Prated is related to the preferential space heater or combination heater. III IV I V Psup / (Prated + Psup)(1)(2) II, package without hot water storage tank II, package with hot water storage tank 124 128

Страница 15 PDF

Страница 16

16 © Baxi Heating UK Ltd 2017 9.0 ErP Information 9.3 Package Fiche - Combination Heaters (Boilers or Heat Pumps) Package fiche for combination heaters (boilers or heat pumps) indicating the water heating energy efficiency of the package AD-3000747-01 % 1 ‘I’ 2 % (1.1 x ‘I’ - 10%) x ‘II’ - - ‘I’ = + ‘III’ <28% XXL XL L M G F E D C B A A + A ++ A +++ 3 % % + 0.4 x = 2 3 % - 0.2 x = 2 3 d ella ts ni e c n o y c n eic fif e y g r e n e la u tc a sti o t d n o p s e rr o c t o n y a m e h c fi sih t ni r o f d e div o r p stc u d o r p f o e g a k c a p e h t f o y c n eic fif e y g r e n e e h T in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. e t a m il c e g a r e v a r e d n u e g a k c a p f o s s a l c y c n e i c fi f e y g r e n e g n it a e h r e t a W e t a m il c e g a r e v a r e d n u e g a k c a p f o y c n e i c fi f e y g r e n e g n it a e h r e t a W yticirtc ele y r ailix u A n o it u b irt n o c r a l o S r e t a e h n o it a n i b m o c f o y c n e i c fi f e y g r e n e g n it a e h r e t a W e civ e d r alo s f o e h c fi m o rf :r e d l o C :r e m r a W s n o iti d n o c e t a m il c r e m r a w d n a r e d l o c r e d n u y c n e i c fi f e y g r e n e g n it a e h r e t a W : el fi o r p d a ol d e r alc e D I The value of the water heating energy efficiency of the combination heater, expressed in %. II The value of the mathematical expression (220 ʷ Qref)/Qnonsol, where Qref is taken from Regulation EU 811/2013, Annex VII Table 15 and Qnonsol from the product fiche of the solar device for the de clared load profile M, L, XL or XXL of the combination heater. III The value of the mathematical expression (Qaux ʷ 2,5)/(220 ʷ Qref), expressed in %, where Qaux is taken from the product fiche of the solar device and Qref from Regulation EU 811/2013, Annex VII Ta ble 15 for the declared load profile M, L, XL or XXL.

Страница 16 PDF

Страница 17

17 © Baxi Heating UK Ltd 2017 Black Taps - Water Yellow Tap - Gas 10.0 Emergency If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and vacate the premises Telephone the National Gas Emergency Service on:- 0800 111 999 Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person. Warning ! 11.1 Disposal and Recycling NOTE: Removal and disposal of the boiler must be carried out by a qualified person in accordance with local and national regulations. 11.0 Disposal Fig. 6 In an Emergency If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves as follows; 1. If a water or gas leak occurs or is suspected, the boiler can be isolated at the inlet valves by turning their taps through 90° (1/4 turn) (Fig. 6). 3. Call your Installer or Service Engineer as soon as possible.

Страница 17 PDF

Страница 18

18 © Baxi Heating UK Ltd 2017 12.0 Notes

Страница 18 PDF

Страница 19

19 © Baxi Heating UK Ltd 2017 12.0 Notes

Страница 19 PDF

Страница 20

7659609-02 (04/17) 0086 Baxi Customer Support 0344 871 1545 Opening hours Monday - Friday, 8.00am-6.00pm Weekends and Bank Holidays, 8.30am-2.00pm Please note calls may be recorded for training and monitoring purposes baxi.co.uk Register now to activate your warranty: www.baxi.co.uk/registration For the warranty to be maintained, please make sure... Benchmark checklist is completed Warranty is registered within 30 days The boiler has an annual service 1 2 3 For full terms and conditions, visit www.baxi.co.uk/terms. Failure to adhere to terms and conditions will void your manufacturer’s warranty. Baxi Brooks House, Coventry Road, Warwick, CV34 4LL Please ensure the boiler is installed in accordance with these installation instructions and that you adhere to the Building Regulations. e&oe All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request.