Сторінка 1

© Baxi Heating UK Ltd 2019 Fitting Instructions GasSaver GS-2 Part No. 7712941

Сторінка 1 PDF

Сторінка 2

2 © Baxi Heating UK Ltd 2019 1.0 introduction 3 2.0 Technical Data 4 3.0 important information & Operation 5 4.0 installation 6 5.0 General notes 7 Section Page Contents © Baxi Heating UK Ltd 2019 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether electronic, mechanical, recording or otherwise, without the prior written permission of the copyright owner, except for permitted fair dealing under Copyrights, Designs and Patents Act 1988. Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick. CV34 4LL Full acknowledgement of author and source must be given. WArninG: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. 0086 Baxi 600 Combi range Baxi 800 Combi range Potterton Assure Combi range Main Eco Compact Combi Baxi 600 System range Baxi 800 System range Potterton Assure System range Main Eco Compact System The GasSaver GS-2 is approved for use with the following boiler models:-

Сторінка 2 PDF

Сторінка 3

© Baxi Heating UK Ltd 2019 i) ii) iii) v) vi) vii) 3 1.1 Description 1. The GasSaver GS-2 Passive Flue Gas Heat Recovery Device as listed in the Government’s Product Characteristics Database (PCDB). 2. The GasSaver uses heat from the flue gases to pre-heat incoming cold mains water, thus reducing gas consumption during the production of Domestic Hot Water. 3. The GasSaver is manufactured under a patent licence from Canetis. 1.2 Contents of Pack The pack contains:- i) GasSaver Unit ii) Support Bracket iii) Wall Fixing Screws Pack iv) Blending Valve v) Template vi) Literature vii) SAP Label for boiler 1.3 Flue Lengths 1. To ensure full boiler output the following equivalent flue length should not be exceeded:- all models - 5 metres Consult the boiler instructions for details of the equivalent length values of any bends. 2. The 60/100 concentric horizontal or vertical flue system (Flue Group A) approved for the boilers listed on p. 2 MUST be used. 3. The GasSaver MUST nOT be used with the 80/125 flue system or Plume Displacement Kits. Where pluming may cause a nuisance it is permissible to use Flue Terminal Deflector part no. 5111068 (Black), 720644201 (White) or 720644301 (Brown). 1.4 Accessory To prevent backflow into the water supply the following items are available as an accessory:- For Combi models Expansion Vessel & Check Valve Kit 720066401 For System models Expansion Vessel & Check Valve Kit 7736697 (inc. 1 x swept tee) 1.0 introduction iv)

Сторінка 3 PDF

Сторінка 4

4 © Baxi Heating UK Ltd 2019 2.0 Technical Data DHW Circuit bar Pressures Max Inlet - 5* Min Operating - 0.2 Connections stainless steel Cold Water Mains Inlet - 15mm Pre-heated Mains Outlet - 15mm DHW Circuit l/min Flow rates Max Flow Rate - up to 15* (*depending on boiler model) Min Flow Rate - 2.5 Weights kg Packaged Weight - 18.4 Installation Lift Weight - 15.6 Weight - Full - 24 Clearances mm Above Casing - 175 mm Below Casing - 80 mm Front - 450 mm Min (For Inspection) Front - 5 mm Min (In Operation) L.H. Side - 5 mm R.H. Side - 5 mm General DHW H/Exch. - Stainless Steel Store & Flue Connection - Stainless Steel Casing - White Paint - Steel Condensate Store Capacity - 5.5 litres H/Exch Coil Capacity - 2.7 litres Blending Valve Connections - 15mm Setting Temperature - 30° C Fig. 1 *if required fit a pressure reducing device to achieve this 278 mm 390mm 290mm Serial No. Position Dimensions (Fig. 1) mm Casing Height - 278mm Casing Width - 390mm Casing Depth - 290mm Overall Depth - 325mm (inc. brackets) note - the GasSaver GS2 overhangs the boiler by 40mm at the front (Fig. 1a). This must be taken into account as the boiler depth plus minimum clearance dimension is no longer valid. 325mm 40mm overhang Fig. 1a

Сторінка 4 PDF

Сторінка 5

5 © Baxi Heating UK Ltd 2019 3.1 important information 1. The GasSaver must only be fitted with one of the range of boilers specified (see p.2). It must be installed in accordance with these instructions, and by a competent person. 2. The current Gas Safety (Installation & Use) Regulations must be observed, along with all relevant Building Regulations/Standards, Water Regulations/Standards and the B.S. Codes of Practice listed in the boiler instructions. 3. A dedicated wall fixing bracket (Section 1.2, item ii) is supplied to mount the GasSaver on - this MUST be used and fitted in accordance with these instructions and as shown on the template supplied. 4. The GasSaver must be fitted on a flat vertical surface. 5. The GasSaver is in effect part of the flue system and should be considered as such. iMPOrTAnT: These instructions must be read in conjunction with those supplied with the boiler. 3.2 Operation (Fig. 2) 1. There are no moving parts in the GasSaver and it does not need any electrical supply. It is fitted to the boiler flue adaptor. 2. The diagram opposite shows how the heat is transferred from the flue gases into the mains cold water. 3. A gas-to-water heat exchanger extracts heat from the discharged products of combustion (hot flue gases). This heat is used to pre-heat the incoming cold mains before it is heated for domestic hot water purposes. 4. During the transfer of heat from the flue gases further condensation occurs, allowing latent heat to be captured. This condensate is utilised to form a thermal store within the GasSaver providing more recovered heat that is used in the pre-heat process. 5. Additionally, as the flue gases leaving the GasSaver contain considerably less moisture, the amount of pluming is reduced. 3.0 important information & Operation Products of Combustion (Hot Flue Gases) Cooler Flue Gases Air for Combustion Pre-heated Incoming Mains Out to Boiler Incoming Cold Mains Condensate Thermal Store Fig. 2

Сторінка 5 PDF

Сторінка 6

6 © Baxi Heating UK Ltd 2019 4.1 installation iMPOrTAnT: Follow the Installation & Servicing Instructions supplied with the boiler to the point at which the wall plate is fitted, but do not mark the flue position. The GasSaver must be fitted on a flat vertical surface. 1. Align the GasSaver template with the wall plate (Fig. 3) and mark the positions of the flue, upper fixings and GasSaver mounting bracket. 2. Drill & plug the upper and bracket fixings. Make the hole for the flue & fit the boiler. 3. Position the GasSaver two piece mounting bracket centrally above the boiler once it is installed (Fig. 4), ensuring the “V” shape locating feature is engaged. 4. The GasSaver can now be fitted. Locate the connection on the underside of the GasSaver in the boiler flue adaptor, taking care to not displace the seals. The GasSaver must be supported before securing. 5. Whilst supporting the GasSaver secure it to the wall with the screws and washers provided using the upper fixing brackets (Fig. 5). The weight of the GasSaver must be taken by the mounting bracket. 6. To ensure correct and efficient operation the GasSaver must now be primed (Fig. 6) by pouring 6 litres of clean cold water into the central spigot. Do not allow any water to spill into the air chamber. 7. The flue system can now be installed (Fig. 7) and commissioning completed. The flue adaptor on top of the GasSaver is the same as that on the boiler. nOTE: Where the installation has been “pre-plumbed” with pipework rising vertically the two piece mounting bracket can be inserted from both sides of the pipe runs (Fig. 8). 4.0 installation Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 “V” locating feature Fig. 8 GasSaver mounting bracket above boiler bracket

Сторінка 6 PDF

Сторінка 7

7 © Baxi Heating UK Ltd 2019 5.1 Pipework (Figs. 9 & 10) 1. Connect the DHW pipework to the GasSaver only using suitable compression fittings with copper olives. Do NOT use push fit or solder fittings. nOTE: To comply with water regulations & byelaws an approved single check valve or some other no less effective backflow prevention device must be fitted at the point of connection between the supply and the device. 2. Combi boilers - Set the blending valve so that mains water is supplied to the boiler at approximately 30° C. Adjust the valve to position “1” and check the water temperature. Further adjustment may be required. 3. System boilers - Ensure that the components of the System Boiler Application kit (7736697 - includes a swept tee) are fitted in accordance with Fig. 11. SySTEM BOiLEr APPLiCATiOnS. it is recommended that the cylinder thermostat is set to 30° C and that the main heat source is enabled for at least one continuous hour per week for pasteurisation. 4. Certain circumstances require the installation of an expansion vessel on the mains inlet - see the relevant section of the boiler Installation & Servicing Instructions. 5. Apply the SAP label to the boiler (Fig. 12) and continue with the installation and commissioning procedure. 6. The GasSaver will operate at full effectiveness after approximately 24 hours operation. 5.2 inspection 1. There are no specific maintenance requirements applicable to the GasSaver. 2. It is recommended that every time the boiler is serviced the GasSaver is subjected to a visual inspection of its overall condition and that of the flue & pipework connections. 5.0 General notes Mains Cold Water Domestic Hot Water Combi GasSaver Expansion Vessel Blending Valve Single Check Valve Cold mains in Pre-heated water for DHW Fig. 10 Fig. 9 Apply SAP Label Combi Boiler Application Fig. 12 Domestic Hot Water System Boiler GasSaver Expansion Vessel 22mm Blending Valve (not supplied) Tundish Discharge Pipe Temp./Pressure Relief Valve Balanced Cold Feed Single Check Valve Stop Valve 3 bar Pressure Reducer Mains Cold Water C.H. Flow & Return Domestic Hot Water Primary Expansion Vessel 22mm 22mm 15mm 22mm 15mm Pressure Relief Valve Single Check Valve 3 bar Pressure Reducer Unvented Cylinder 22-22-15 Swept Tee (note direction of sweep) 15mm 22mm A B From A to B (GasSaver outlet to cylinder) pipe should be insulated and kept as short as possible Scale Reducer (recommended if water hardness level > 200ppm of calcium carbonate) Fig. 11 System Boiler Application

Сторінка 7 PDF

Сторінка 8

© Baxi Heating UK Ltd 2019 Baxi Customer Support 0344 871 1545 Opening hours Monday - Friday, 8.00am-6.00pm Weekends and Bank Holidays, 8.30am-2.00pm Please note calls may be recorded for training and monitoring purposes baxi.co.uk Baxi Brooks House, Coventry Road, Warwick, CV34 4LL e&oe All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. part of 7712739-03 (9 /19) potterton.co.uk

Сторінка 8 PDF